The Accuracy of Large Loop Excision of the Transformation Zone Specimen Dimensions in Determining Volume: A Multicentric Prospective Observational Study

被引:3
|
作者
Carcopino, Xavier [1 ]
Mancini, Julien [2 ,3 ]
Prendiville, Walter [4 ]
Gondry, Jean [5 ]
Chevreau, Julien [5 ]
Lamblin, Gery [6 ]
Atallah, Anthony [6 ]
Lavoue, Vincent [7 ]
Caradec, Claire [7 ]
Baldauf, Jean-Jacques [8 ]
Bryand, Angelique [8 ]
Henno, Sebastien [9 ]
Agostini, Aubert [10 ]
Douvier, Serge [11 ]
Jarniat, Adelaide [11 ]
Riethmuller, Didier [12 ]
Mendel, Anne [12 ]
Brun, Jean-Luc [13 ]
Rakotomahenina, Hajanarina [13 ]
Preaubert, Lise [1 ]
机构
[1] Aix Marseille Univ, Hop Nord, APHM, Dept Obstet & Gynaecol,CNRS,IRD, Marseille, France
[2] Aix Marseille Univ, INSERM, IRD, Marseille, France
[3] Hop la Timone, APHM, Dept Publ Hlth, BioSTIC, Marseille, France
[4] WHO, Int Agcy Res Canc, Lyon, France
[5] Jules Verne Univ, Univ Hosp Amiens, Picardie, France
[6] Femme Mere Enfant Univ Hosp, Dept Obstet & Gynaecol, Lyon, France
[7] Univ Rennes 1, Dept Gynaecol, Teaching Hosp Rennes, Rennes, France
[8] Strasbourg Univ Hosp, Hosp Hautepierre, Dept Obstet & Gynaecol, Strasbourg, France
[9] CHU Pontchaillou, Dept Pathol, Rennes, France
[10] Aix Marseille Univ, Hop Concept, APHM, Dept Obstet & Gynaecol, Marseille, France
[11] CHU Dijon, Dept Gynaecol & Oncol Surg, Dijon, France
[12] Univ Hosp Jean Minjoz, Pole Mere Femme, Besancon, France
[13] Hop Pellegrin, Ctr Alienor Aquitaine, Pole Obstet Reprod Gynecol, Bordeaux, France
关键词
volume; dimensions; calculation; LLETZ; formula; CERVICAL INTRAEPITHELIAL NEOPLASIA; DIRECT COLPOSCOPIC VISION; PRETERM DELIVERY; PREGNANCY OUTCOMES; LLETZ PROCEDURE; COHORT; RISK; CONIZATION; DEPTH;
D O I
10.1097/LGT.0000000000000283
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The aim of the study was to determine which mathematical formula of specimen dimensions is the most accurate method of determining volume of the excised specimen at loop excision of the transformation zone. Materials and Methods: A multicenter prospective observational study was conducted. A total of 258 patients who had a loop excision of the transformation zone performed as treatment of cervical intraepithelial neoplasia 2-3 were included. The dimensions and the volume of the specimen were measured at the time of the procedure, before formaldehyde fixation. The volume was measured by immersing the specimen in a graduated cylinder using Archimedes fluid displacement technique. The measured volume was compared with the calculated volume using different volume formulas, that is, a cone, a cylinder, a parallelepiped, and a hemiellipsoid. The main outcome measure was the relationship between calculated volume (using the dimensions of thickness, length, and circumference) and the measured volume of the specimen. Results: The mean (SD) thickness, length, and circumference of specimens were 8.8 mm (3.8), 12.7 mm (5.9), and 45.7 mm (16.8), respectively. The mean (SD) measured volume was 2.53 (1.49) mL. Using the formula for the volume of a cone, a cylinder, a parallelepiped and a hemiellipsoid, estimated volumes were 1.03 mL (1.22), 3.10 mL (3.65), 6.20 mL (7.31), and 2.07 mL (2.44), respectively. The highest intraclass correlation coefficient between measured and calculated volume was observed when using the formula for the volume of a hemiellipsoid specimen (0.47, 95% CI = 0.36-0.56). Conclusions: The hemiellipsoid formula is the most accurate determinant of the excised volume. Other formulas do not allow for an accurate estimation of the excised volume.
引用
收藏
页码:120 / 124
页数:5
相关论文
共 50 条
  • [21] LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE (LLETZ) AND PREGNANCY OUTCOME
    Vaughan, D.
    Mullers, S.
    Daly, S.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : 161 - 161
  • [22] A prospective study of the correlation between Chlamydia trachomatis infection and secondary bleeding following large loop excision of the transformation zone (LLETZ)
    Arko, D
    Takac, I
    WIENER KLINISCHE WOCHENSCHRIFT, 2001, 113 : 11 - 13
  • [23] The use of large loop excision of the transformation zone (LLETZ) in an outpatient setting
    Powell, B
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1996, 36 (03): : 338 - 346
  • [24] Comparison of Recurrence Rates with Contour-Loop Excision of the Transformation Zone (C-LETZ) and Large Loop Excision of the Transformation Zone (LLETZ) for CIN
    Boonlikit, Sathone
    Srichongchai, Hemwadee
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (15) : 6005 - 6008
  • [25] EFFICACY OF LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE FOR CERVICAL INTRAEPITHELIAL NEOPLASIA
    CHIA, KV
    FAYLE, RJS
    SOBOWALE, OA
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1993, 33 (03): : 287 - 289
  • [26] Pregnancy Outcome Following Large Loop Excision of the Transformation Zone (LLETZ)
    Prabhu, T. Radha Bai
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2010, 60 (02): : 149 - 151
  • [27] How do I perform a large loop excision of the transformation zone?
    Jauffret, C.
    Carcopino, X.
    Bretelle, F.
    Boubli, L.
    GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2010, 38 (12): : 790 - 791
  • [28] INVASIVE CERVICAL DISEASE FOLLOWING LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE
    SHAFI, MI
    CHENOY, R
    BUXTON, EJ
    LUESLEY, DM
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (07): : 614 - 614
  • [29] PREGNANCY OUTCOME AFTER LARGE LOOP EXCISION OF THE CERVICAL TRANSFORMATION ZONE
    BLOMFIELD, PI
    BUXTON, J
    DUNN, J
    LUESLEY, DM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (03) : 620 - 625
  • [30] Double Cervical Ostia After Large Loop Excision of Transformation Zone
    Ragupathy, Kalpana
    Ndumbe, Franz
    JOURNAL OF LOWER GENITAL TRACT DISEASE, 2012, 16 (03) : 330 - 332