Ablation of Complex Fractionated Atrial Electrograms for Atrial Fibrillation Rhythm Control: A Systematic Review and Meta-analysis

被引:13
|
作者
Fadahunsi, Opeyemi [1 ]
Talabi, Taiwo [2 ]
Olowoyeye, Abiola [3 ]
Iluyomade, Anthony [4 ]
Shogbesan, Oluwaseun [1 ]
Donato, Anthony [1 ,5 ]
机构
[1] Reading Hlth Syst, Dept Med, Sixth Ave & Spruce St, W Reading, PA 19611 USA
[2] Univ S Florida, H Lee Moffitt Canc Ctr, Tampa, FL 33682 USA
[3] Childrens Hosp Los Angeles, Los Angeles, CA 90027 USA
[4] St Johns Episcopal Hosp, Far Rockaway, NY USA
[5] Thomas Jefferson Univ, Jefferson Med Coll, Dept Med, Philadelphia, PA 19107 USA
关键词
PULMONARY VEIN ISOLATION; CATHETER ABLATION; TRIGGER ABLATION; FOLLOW-UP; MULTICENTER; STRATEGIES; MANAGEMENT; SUBSTRATE; EFFICACY; SOCIETY;
D O I
10.1016/j.cjca.2015.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulmonary vein isolation (PVI) has become an increasingly important therapy in the management of atrial fibrillation (AF), however, the best procedural techniques to ensure success have not been determined. We assessed the incremental benefit of complex fractionated atrial electrograms (CFAEs) ablation for AF rhythm control. Methods: PubMed, Embase, CENTRAL, and Clinicaltrials. gov databases were searched up until May 7, 2015. Included were randomized controlled trials that compared PVI with PVI and CFAEs ablation (PVI+) with a minimum of 3 months' follow-up. Statistical analysis was performed with Review Manager version 5.3 (Cochrane Collaboration, Oxford, United Kingdom). Categorical and continuous outcomes were reported as summary risk differences and mean differences (MDs), respectively. P < 0.05 was considered statistically significant for all analyses. Results: Ten randomized controlled trials randomized patients to PVI+ (n = 635) and PVI (n = 427) with follow-up ranging from 3 to 23 months. There was no significant difference in freedom from atrial tachyarrhythmias without antiarrhythmic agents after a single ablation between PVI+ and PVI (313 of 635 vs 230 of 427; risk difference, 0.01 [95% confidence interval (CI) -0.08 to 0.10]; P = 0.78; I-2 = 52%). Findings were not different for any prespecified subgroup analyses, including paroxysmal vs nonparoxysmal AF, automated vs manual detection of CFAEs, and left atrial vs biatrial ablation. PVI+ led to significantly increased procedure time (MD, 49.81 minutes [95% CI 42.86-56.76]; P < 0.001), fluoroscopy time (MD, 11.55 minutes [95% CI 8.02-15.07]; P < 0.001), and radiofrequency energy application time (MD, 19.16 minutes [95% CI 6.61-31.70]; P = 0.003) compared with PVI. Conclusions: Ablation of CFAEs in addition to PVI did not increase freedom from atrial tachyarrhythmias but procedural times were increased.
引用
收藏
页码:791 / 802
页数:12
相关论文
共 50 条
  • [21] Consistency of complex fractionated atrial electrograms during atrial fibrillation
    Lin, Yenn-Jiang
    Tai, Ching-Tai
    Kao, Tsair
    Chang, Shih-Lin
    Wongcharoen, Wanwarang
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Udyavar, Ameya R.
    Chen, Yi-Jen
    Higa, Satoshi
    Ueng, Kuo-Chang
    Chen, Shih-Ann
    HEART RHYTHM, 2008, 5 (03) : 406 - 412
  • [22] Complex Fractionated Atrial Electrograms Is This the Beast to Tame in Atrial Fibrillation?
    Berenfeld, Omer
    Jalife, Jose
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (04): : 426 - 428
  • [23] Impact of left atrial appendage ridge ablation on the complex fractionated electrograms in persistent atrial fibrillation
    Nakahara, Shiro
    Hori, Yuichi
    Hayashi, Akiko
    Kobayashi, Sayuki
    Nakamura, Hidehiko
    Okumura, Yasuo
    Takayanagi, Kan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (01) : 55 - 64
  • [24] Impact of left atrial appendage ridge ablation on the complex fractionated electrograms in persistent atrial fibrillation
    Shiro Nakahara
    Yuichi Hori
    Akiko Hayashi
    Sayuki Kobayashi
    Hidehiko Nakamura
    Yasuo Okumura
    Kan Takayanagi
    Journal of Interventional Cardiac Electrophysiology, 2014, 41 : 55 - 64
  • [25] Complex fractionated atrial electrograms in atrial fibrillation: A promising target for ablation, but why, when, and how?
    Kottkamp, Hans
    Hindricks, Gerd
    HEART RHYTHM, 2007, 4 (08) : 1021 - 1023
  • [26] The Role of Complex Fractionated Atrial Electrograms in Atrial Fibrillation Ablation Moving to the Beat of a Different Drum
    Nademanee, Koonlawee
    Oketani, Naoya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (09) : 790 - 791
  • [27] Multifractal analysis for grading complex fractionated electrograms in atrial fibrillation
    Orozco-Duque, A.
    Novak, D.
    Kremen, V.
    Bustamante, J.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (11) : 2269 - 2284
  • [28] Is ablation to atrial fibrillation termination of persistent atrial fibrillation the end point? A systematic review and meta-analysis
    Li, Fanghui
    Tu, Xiang
    Li, Dongze
    Jiang, Ying
    Cheng, Yisong
    Jia, Yu
    Zhang, Xinyu
    Fu, Hua
    Hu, Hongde
    Jiang, Jian
    Zeng, Rui
    MEDICINE, 2019, 98 (47)
  • [29] Is there a relationship between complex fractionated atrial electrograms recorded during atrial fibrillation and sinus rhythm fractionation?
    Saghy, Laszlo
    Callans, David J.
    Garcia, Fermin
    Lin, David
    Marchlinski, Francis E.
    Riley, Michael
    Dixit, Sanjay
    Tzou, Wendy S.
    Haqqani, Harris M.
    Pap, Robert
    Kim, Steven
    Gerstenfeld, Edward P.
    HEART RHYTHM, 2012, 9 (02) : 181 - 188
  • [30] Hybrid Convergent ablation for atrial fibrillation: A systematic review and meta-analysis
    Shrestha, Suvash
    Plasseraud, Kristen M.
    Makati, Kevin
    Sood, Nitesh
    Killu, Ammar M.
    Contractor, Tahmeed
    Ahsan, Syed
    De Lurgio, David B.
    Shults, Christian C.
    Eldadah, Zayd A.
    Russo, Andrea M.
    Knight, Bradley
    Greenberg, Yisachar Jesse
    Yang, Felix
    HEART RHYTHM O2, 2022, 3 (04): : 396 - 404