Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise

被引:50
|
作者
Habazettl, Helmut [1 ,2 ]
Athanasopoulos, Dimitris [3 ,4 ]
Kuebler, Wolfgang M. [1 ,2 ]
Wagner, Harrieth [5 ]
Roussos, Charis [3 ]
Wagner, Peter D. [5 ]
Ungruhe, Juergen [1 ]
Zakynthinos, Spyros [3 ]
Vogiatzis, Ioannis [3 ,4 ]
机构
[1] Charite CBF, Inst Physiol, D-14195 Berlin, Germany
[2] German Heart Inst, Inst Anesthesiol, Berlin, Germany
[3] Univ Athens, M Simou & GP Livanos Labs, Evangelismos Hosp, Dept Crit Care Med & Pulm Serv, Athens, Greece
[4] Univ Athens, Dept Phys Educ & Sport Sci, Athens, Greece
[5] Univ Calif San Diego, Dept Med, La Jolla, CA 92093 USA
关键词
exercise; Fick principle; interobserver variability; NIRS; PULSE DYE DENSITOMETRY; NEWBORN PIGLETS;
D O I
10.1152/japplphysiol.01269.2009
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Habazettl H, Athanasopoulos D, Kuebler WM, Wagner H, Roussos C, Wagner PD, Ungruhe J, Zakynthinos S, Vogiatzis I. Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise. J Appl Physiol 108: 962-967, 2010. First published January 28, 2010; doi: 10.1152/japplphysiol.01269.2009.-Near-infrared spectroscopy (NIRS) with the tracer indocyanine green (ICG) may be used for measuring muscle blood flow (MBF) during exercise, if arterial ICG concentration is measured simultaneously. Although pulse dye densitometry allows for noninvasive measurement of arterial dye concentration, this technique is sensitive to motion and may not be applicable during exercise. The aim of this study was to evaluate a noninvasive blood flow index (BFI), which is derived solely from the muscle ICG concentration curve. In 10 male cyclists 5 mg ICG were injected into an antecubital vein at rest and during cycling at 30, 60, 70, 80, 90, and 100% of previously determined maximal work load. Simultaneously blood was withdrawn through a photodensitometer at 20 ml/min from the radial artery to measure arterial ICG concentration. To measure muscle tissue ICG concentrations, two sets of NIRS optodes were positioned on the skin, one over the left seventh intercostal space and the other over the left vastus lateralis muscle. MBF was calculated from the arterial and muscle concentration data according to Fick's principle. BFI was calculated solely from the muscle concentration curve as ICG concentration difference divided by rise time between 10 and 90% of peak. During exercise mean BFI values changed similarly to MBF in both intercostal and quadriceps muscles and showed excellent correlations with MBF: r = 0.98 and 0.96, respectively. Individual data showed some scattering among BFI and MBF values but still reasonable correlations of BFI with MBF: r = 0.73 and 0.72 for intercostal and quadriceps muscles, respectively. Interobserver variability, as analyzed by Bland-Altman plots, was considerably less for BFI than MBF. These data suggest that BFI can be used for measuring changes in muscle perfusion from rest to maximal exercise. Although absolute blood flow cannot be determined, BFI has the advantages of being essentially noninvasive and having low interobserver variability.
引用
收藏
页码:962 / 967
页数:6
相关论文
共 50 条
  • [11] Measurement of cerebral blood volume using near-infrared spectroscopy and indocyanine green elimination
    Hopton, P
    Walsh, TS
    Lee, A
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (05) : 1981 - 1987
  • [12] Near-infrared spectroscopy using indocyanine green dye for minimally invasive measurement of respiratory and leg muscle blood flow in patients with COPD
    Louvaris, Zafeiris
    Habazettl, Helmut
    Wagner, Harrieth
    Zakynthinos, Spyros
    Wagner, Peter
    Vogiatzis, Ioannis
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 125 (03) : 947 - 959
  • [13] Noninvasive in vivo measurement of venous blood pH during exercise using near-infrared reflectance spectroscopy
    Yang, Ye
    Soyemi, Olusola O.
    Landry, Michelle R.
    Soller, Babs R.
    APPLIED SPECTROSCOPY, 2007, 61 (02) : 223 - 229
  • [14] Measurement of cerebral blood flow with near infrared spectroscopy and indocyanine green dye dilution
    Keller, Emanuela
    Mudra, Regina
    CURRENT MEDICAL IMAGING, 2007, 3 (02) : 139 - 150
  • [15] Measurement of cerebral blood volume using near-infrared spectroscopy and indocyanine green elimination - Commentary
    Sieck, GC
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (05) : 1988 - 1989
  • [16] Respiratory and locomotor muscle blood flow measurements using near-infrared spectroscopy and indocyanine green dye in health and disease
    Megaritis, Dimitrios
    Echevarria, Carlos
    Vogiatzis, Ioannis
    CHRONIC RESPIRATORY DISEASE, 2024, 21
  • [17] Measurement of oxygen consumption during muscle flaccidity exercise by near-infrared spectroscopy
    Fukuda, K.
    Fukawa, Y.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE X, 2013, 8578
  • [18] Measurement of Cerebral Blood Flow in Newborn Infants Using Near Infrared Spectroscopy with Indocyanine Green
    Jayesh Patel
    Kyla Marks
    Idris Roberts
    Denis Azzopardi
    Anthony David Edwards
    Pediatric Research, 1998, 43 : 34 - 39
  • [19] Measurement of cerebral blood flow in newborn infants using near infrared spectroscopy with indocyanine green
    Patel, J
    Marks, K
    Roberts, I
    Azzopardi, D
    Edwards, AD
    PEDIATRIC RESEARCH, 1998, 43 (01) : 34 - 39
  • [20] Measurement of Skeletal Muscle Blood Flow with Near-infrared Diffuse Correlation Spectroscopy
    Rosenberry, Ryan
    Ganesh, Chandan
    Tian, Fenghua
    Nelson, Michael D.
    FASEB JOURNAL, 2017, 31