In vivo evaluation of a new composite mesh (10% polypropylene/90% poly-L-lactic acid) for hernia repair

被引:22
|
作者
Tanaka, Keitaro
Mutter, Didier
Inoue, Harutaka
Lindner, Veronique
Bouras, George
Forgione, Antonello
Leroy, Joel
Aprahamian, Marc
Marescaux, Jacques
机构
[1] Univ Strasbourg, IRCAD EITS, F-67091 Strasbourg, France
[2] Hop Civil, Inst Pathol, F-67000 Strasbourg, France
关键词
ABDOMINAL-WALL HERNIAS; CHRONIC PAIN; TERM; LICHTENSTEIN; REGENERATION; SHOULDICE; QUESTIONNAIRE; IMPLANTATION; MACROPHAGE; CELLS;
D O I
10.1007/s10856-006-0090-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The increasing use of mesh insertion for groin hernia repair is dashed by a worrying prevalence of chronic pain frequently related as a reaction to the biomaterial implantation. Thus, new biocompatible prosthesis, designed as a composite material associating polypropylene (PP) and long-term absorbable material, are now under development. In the present study, the typical commercially available Prolene(R) mesh has been compared to two new meshes designed with 3-fold less PP, either alone (light PP) or associated with poly-L-lactic acid (PP-PLA) accounting for 90% of the mesh weight. These PP-mesh variants were implanted in an extraperitoneal position within the abdominal wall of 90 rats. Mesh adhesion and size were determined at autopsy 2, 4 and 8 weeks after implantation (10 animals per group) and morphometric parameters of the host tissues by light microscopy. Prolene(R) and light PP-meshes presented intra-corporeal shrinkage and tissue adhesion, both more pronounced with light-PP, whilst PP-PLA meshes were not affected in spite of a strongest fibrosis. In contrast to Prolene(R) and even more with light PP meshes, inflammation and cell-mediated immune responses were reduced without occurrence of angiogenesis or oedema. All these findings advocate together for a better tolerance of this new composite biomaterial, more likely due to a low macrophage response that appeared statistically correlated to the absence of mesh shrinkage and to a decreased adhesion to the tissue. On the basis of these experimental observations, it could be expected that the better tolerance of this composite biomaterial may avoid both long-term pain and recurrence when used as plug in groin hernia repair.
引用
收藏
页码:991 / 999
页数:9
相关论文
共 50 条
  • [31] Invited Discussion on: Comparative Evaluation of Safety and Efficacy of a Novel Hyaluronic Acid Polynucleotide/Poly-L-Lactic Acid Composite Dermal Filler
    Claudio DeLorenzi
    Aesthetic Plastic Surgery, 2021, 45 : 1802 - 1803
  • [33] Effect of Hyaluronic Acid and Poly-L-Lactic Acid Dermal Fillers on Collagen Synthesis: An in vitro and in vivo Study
    Bertelli Cabral, Larissa Rocha
    Teixeira, Lucas Novaes
    Gimenez, Rodrigo Pinto
    Dias Demasi, Ana Paula
    de Brito, Rui Barbosa
    de Araujo, Vera Cavalcanti
    Martinez, Elizabeth Ferreira
    CLINICAL COSMETIC AND INVESTIGATIONAL DERMATOLOGY, 2020, 13 : 701 - 710
  • [34] Complications Observed Following Labral or Rotator Cuff Repair with Use of Poly-L-Lactic Acid Implants
    McCarty, L. Pearce, III
    Buss, Daniel D.
    Dana, Milton W.
    Freehill, Michael Q.
    Giveans, M. Russell
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (06): : 507 - 511
  • [35] Drug release evaluation of Paclitaxel/Poly-L-Lactic acid nanoparticles based on a microfluidic chip
    Zhang, Xiang
    Guan, Guotao
    Wang, Zhenxing
    Lv, Li
    Chavez-Madero, Carolina
    Chen, Mo
    Yan, Zhenhao
    Yan, Shujie
    Wang, Lixia
    Li, Qian
    BIOMEDICAL MICRODEVICES, 2021, 23 (04)
  • [36] Drug release evaluation of Paclitaxel/Poly-L-Lactic acid nanoparticles based on a microfluidic chip
    Xiang Zhang
    Guotao Guan
    Zhenxing Wang
    Li Lv
    Carolina Chávez-Madero
    Mo Chen
    Zhenhao Yan
    Shujie Yan
    Lixia Wang
    Qian Li
    Biomedical Microdevices, 2021, 23
  • [37] In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors
    Department of Biomedical Engineering, Duke University, Durham, NC, United States
    不详
    J. Biomed. Mater. Res. Part B Appl. Biomater., 2008, 3 (792-807):
  • [38] The use of poly-L-lactic acid in lumbar interbody cages: design and biomechanical evaluation in vitro
    van Dijk, M
    Smit, TH
    Arnoe, MF
    Burger, EH
    Wuisman, PI
    EUROPEAN SPINE JOURNAL, 2003, 12 (01) : 34 - 40
  • [39] In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors
    Koschwanez, H. E.
    Yap, F. Y.
    Klitzman, B.
    Reichert, W. M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 87A (03) : 792 - 807
  • [40] Evaluation of absorbable electrified poly-L-lactic acid membrane for bone regeneration in rats.
    Tanaka, H
    Ohtsuka, H
    Mushimoto, E
    Sato, H
    Chiba, S
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 3127 - 3127