Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:9
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 122卷 / 05期
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [31] Research on the Connection Performance of Variable Pitch of Screw Threaded Casing Based on 3D Finite Element Simulation Model
    Guo, Xiong
    Zou, Lvlong
    Lu, Bing
    Zhang, Shiliang
    Su, Xingren
    Xu, Hui
    ADVANCES IN DESIGN TECHNOLOGY, VOLS 1 AND 2, 2012, 215-216 : 1105 - +
  • [32] Different Conical Angle Connection of Implant and Abutment Behavior: A Static and Dynamic Load Test and Finite Element Analysis Study
    Kortvelyessy, Gyozo
    Szabo, Arpad Laszlo
    Pelsoczi-Kovacs, Istvan
    Tarjanyi, Tamas
    Toth, Zsolt
    Karpati, Krisztina
    Matusovits, Danica
    Hangyasi, Botond David
    Barath, Zoltan
    MATERIALS, 2023, 16 (05)
  • [33] 3D finite element modelling of a carpometacarpal implant coated with hydroxyapatite
    Lbath, F
    Rumelhart, C
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 447 - 454
  • [34] Effect of Different Customized Abutment Types on Stress Distribution in Implant-Supported Single Crown: A 3D Finite Element Analysis
    Pumnil, Suphakrit
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Elsaka, Shaymaa
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : E2 - E11
  • [35] The Influence of a Positioning Hex on Abutment Rotation in Tapered Internal Implants: A 3D Finite Element Model Study
    Hyun, Dong-Geun
    Kwon, Ho-Beom
    Lim, Young-Jun
    Koak, Jai-Young
    Kim, Myung-Joo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (02) : 281 - 288
  • [36] Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection
    Cho, Sung-Yong
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (03) : E49 - E58
  • [37] Effect of implant-abutment connections with peri-implant bone defect models under removal torque force: A 3D finite element analysis
    Corekci, Ahu Uraz
    Isler, Sila Cagri
    Sengul, Janset
    Guler, Berceste
    Ozdemir, Yucel
    Ozbay, Deniz
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 (04): : 358 - 364
  • [38] 3D Finite Element Study of Biomechanical Performances of Short Implant Supporting Fixed Prosthesis
    Sanpanyawai, Pornpon
    Inglam, Samroeng
    Chaichanasiri, Ekachai
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 669 - 673
  • [39] Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Suriyawanakul, Jarupol
    Li, Qing
    Sasaki, Keiichi
    Yoda, Nobuhiro
    Rungsiyakull, Pimduen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (08): : 815 - 823
  • [40] 3D Finite Element Modeling of an Assembly Process With Thread Forming Screw
    Mathurin, Florestan
    Guillot, Jean
    Stephan, Pierre
    Daidie, Alain
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04): : 0410151 - 04101518