Performance evaluation of the Philips MOSAIC small animal PET scanner

被引:85
|
作者
Huisman, Marc C.
Reder, Sybille
Weber, Axel W.
Ziegler, Sibylle I.
Schwaiger, Markus
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-81675 Munich, Germany
[2] Philips Res Labs, Aachen, Germany
关键词
small animal PET; instrumentation; performance evaluation; PET; imaging;
D O I
10.1007/s00259-006-0271-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In this study an evaluation of the performance of the Philips MOSAIC small animal PET scanner is presented, with special emphasis on the ability of the system to provide quantitatively accurate PET images. Methods The performance evaluation was structured according to NEMA-like procedures. Results The transaxial spatial resolution of the system (radial component) ranged between 2.7 mm FWHM at the centre and 3.2 mm FWHM at a radial offset of 45 mm from the centre. The axial spatial resolution of the system ranged between 3.4 mm FWHM at the centre and 5.8 mm FWHM at a radial offset of 45 mm from the centre. The scatter fraction was determined for a mouse- as well as for a rat-sized phantom, and the values obtained were 9.6% and 16.8%, respectively. For the mouse phantom, the maximum count rate measured was 560 kcps at 93 MBq; the maximum NEC rate equalled 308 kcps at 1.7 MBq/ml. For the rat phantom, these values were 400 kcps at 100 MBq and 129 kcps at 0.24 MBq/ml, respectively. The sensitivity of the system was derived to be 0.65%. An energy window between 410 and 665 keV was used in all experiments. Conclusion The MOSAIC system exhibits moderate spatial resolution and sensitivity values, but good NEC performance. In combination with its relatively large field of view, the system allows for high-throughput whole-body imaging of mice and rats. The accurate measurement of relative changes in radiotracer distributions is feasible.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
  • [21] Performance Evaluation of a PEM Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Christopher G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 94 - 103
  • [22] Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET
    Mizuta, Tetsuro
    Kitamura, Keishi
    Iwata, Hiroshi
    Yamagishi, Yoshiyuki
    Ohtani, Atsushi
    Tanaka, Kazumi
    Inoue, Yoshihiro
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (05) : 447 - 455
  • [23] Design and performance evaluation of high resolution small animal PET scanner based on monolithic crystal: a simulation study
    Sanaat, A.
    Zafarghandi, M. S.
    Ay, M. R.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (01)
  • [24] Initial performance evaluation of a.modular, large-area detector PET scanner for small animal imaging
    Kao, Chien-Min
    Souris, Jeffrey S.
    Cho, Seungryong
    Penney, Bill C.
    Chen, Chin-Tu
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2081 - 2084
  • [25] Performance Assessment of a Preclinical PET Scanner with Pinhole Collimation by Comparison to a Coincidence-Based Small-Animal PET Scanner
    Walker, Matthew D.
    Goorden, Marlies C.
    Dinelle, Katherine
    Ramakers, Ruud M.
    Blinder, Stephan
    Shirmohammad, Maryam
    van der Have, Frans
    Beekman, Freek J.
    Sossi, Vesna
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (08) : 1368 - 1374
  • [26] Imaging performance of A-PET, a GSO small animal 3-D PET scanner.
    Perkins, AE
    Surti, S
    Karp, JS
    Muehllehner, G
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 9P - 9P
  • [27] System electronics for the MiCES small animal PET scanner
    Lewellen, TK
    Miyaoka, RS
    Janes, M
    Park, B
    Gillispie, SG
    Lee, K
    Kinahan, PE
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1770 - 1774
  • [28] System Integration of the LabPET™ Small Animal PET Scanner
    Tetrault, M. -A.
    Viscogliosi, N.
    Riendeau, J.
    Belanger, F.
    Michaud, J. B.
    Semmaoui, H.
    Berard, P.
    Lemieux, F.
    Arpin, L.
    Cadorette, J.
    Pepin, C. M.
    Robert, G.
    Lepage, M. D.
    Lecomte, R.
    Fontaine, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1880 - 1884
  • [29] Design of a small animal MR compatible PET scanner
    Slates, R
    Cherry, S
    Boutefnouchet, A
    Shao, YP
    Dahlbom, M
    Farahani, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 565 - 570
  • [30] System Architecture of the LabPET Small Animal PET Scanner
    Tetrault, Mare-Andre
    Viscogliosi, Nicolas
    Riendeau, Joel
    Belanger, Francois
    Michaud, Jean-Baptiste
    Semmaoui, Hicham
    Berard, Philippe
    Lemieux, Francois
    Arpin, Louis
    Bergeron, Melanie
    Cadorette, Jules
    Pepin, Catherine M.
    Robert, Ghislain
    Lepage, Martin D.
    Lecomte, Roger
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2546 - 2550