Analysis and Research of Three-phase Unbalance in Distribution Transformers

被引:0
|
作者
Pan, Benren [1 ]
Zhang, Yan [1 ]
Gui, Xiaozhi [1 ]
Wan, Yong [1 ]
Wang, Guannan [1 ]
机构
[1] Elect Power Res Inst Jiangxi Prov, Nanchang, Jiangxi, Peoples R China
关键词
D O I
10.1088/1755-1315/252/3/032196
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The distribution transformer unbalanced operation status will affect the life of the transformer and increase the losses of the transformer besides a series of problems such as grid voltage drop, flicker, low power factor, line losses increase. This article analysis harm caused by the unbalanced operation of distribution transformers from the perspective of power quality and the measures dealing with three-phase unbalanced of distribution transformers.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A new three-phase transformer modeling for three-phase harmonic analysis in distribution systems
    de Morais, TM
    Canesin, CA
    Wakabayashi, FT
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 1266 - 1271
  • [42] Modified Thermal Circuit Model for Distribution Transformers in Three-phase Unbalanced Operation
    Ding, Yuqin
    Zhang, Qiaogen
    Liu, Xuandong
    Gao, Meng
    Wang, Tonglei
    Ni, Heli
    Yuan, Weixiong
    Liu, Guangqi
    Wang, Ke
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 473 - 477
  • [43] Measurements and model validation on three-phase core-type distribution transformers
    Carneiro, S
    Martins, HJA
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 120 - 124
  • [44] Phase reassignment strategy and load phase-swapping device for three-phase unbalance in the power distribution area
    Zhang, Yi
    Sun, Xianbo
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 235
  • [45] Three-limb amorphous magnetic circuit for three-phase 200 kVA distribution transformers
    Inst of Non-Ferrous Metals, Gliwice, Poland
    J Magn Magn Mater, (213-214):
  • [46] A three-limb amorphous magnetic circuit for three-phase 200 kVA distribution transformers
    Kolano, R
    Wojcik, N
    Gawior, W
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1996, 160 : 213 - 214
  • [47] The Research of Unbalanced Three-phase Adjustment in Distribution Network
    Zheng, Yanwei
    Bai, Zhonghai
    Feng, Zhiquan
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY, PTS 1-4, 2013, 263-266 : 649 - +
  • [48] Analysis of effects of three-phase voltage unbalance on induction motors with emphasis on the angle of the complex voltage unbalance factor
    Wang, YJ
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2001, 16 (03) : 270 - 275
  • [49] Study of Dynamic Properties of Three-phase Transformers
    Gayfutdinova, Elmira
    Ozerova, Ekaterina
    Bazhenov, Nikolai
    2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,
  • [50] Space vector transients of three-phase transformers
    Bellan D.
    International Journal of Circuits, Systems and Signal Processing, 2020, 14 : 700 - 707