Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry

被引:68
|
作者
Ternacle, Julien [1 ]
Pibarot, Philippe [1 ]
Herrmann, Howard C. [2 ]
Kodali, Susheel [3 ]
Leipsic, Jonathon [4 ]
Blanke, Philipp [4 ]
Jaber, Wael [5 ]
Mack, Michael J. [6 ]
Clavel, Marie-Annick [1 ]
Salaun, Erwan [1 ]
Guzzetti, Ezequiel [1 ]
Annabi, Mohamed-Salah [1 ]
Bernier, Mathieu [1 ]
Beaudoin, Jonathan [1 ]
Khalique, Omar K. [3 ]
Weissman, Neil J. [7 ]
Douglas, Pamela [8 ]
Bax, Jeroen [9 ]
Dahou, Abdellaziz [10 ]
Xu, Ke [11 ]
Alu, Maria [3 ,10 ]
Rogers, Erin [11 ]
Leon, Martin [3 ,10 ]
Thourani, Vinod H. [12 ]
Abbas, Amr E. [13 ,14 ]
Hahn, Rebecca T. [3 ,10 ]
机构
[1] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Columbia Univ, Med Ctr, NewYork Presbyterian Hosp, New York, NY USA
[4] Univ British Columbia, St Pauls Hosp, Vancouver, BC, Canada
[5] Cleveland Clin, Cleveland, OH 44106 USA
[6] Baylor Scott & White Healthcare, Plano, TX USA
[7] Georgetown Univ, MedStar Heath Res Inst, Washington, DC USA
[8] Duke Univ, Duke Clin Res Inst, Med Ctr, Durham, NC USA
[9] Leiden Univ, Dept Cardiol, Med Ctr, Leiden, Netherlands
[10] Cardiovasc Res Fdn, New York, NY USA
[11] Edwards Lifesci, Irvine, CA USA
[12] Marcus Valve Ctr, Piedmont Heart Inst, Dept Cardiovasc Surg, Atlanta, GA USA
[13] Oakland Univ, William Beaumont Sch Med, Auburn Hills, MI USA
[14] Beaumont Hosp Royal Oak, Royal Oak, MI USA
关键词
aortic stenosis; effective orifice area; prosthetic heart valve; prosthesis-patient mismatch; transcatheter aortic valve replacement; transvalvular pressure gradient; INTERMEDIATE-RISK PATIENTS; END-POINT DEFINITIONS; LONG-TERM SURVIVAL; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; TRANSCATHETER; OUTCOMES; IMPACT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.jcin.2021.03.069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). BACKGROUND TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. METHODS The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <= 0.85 cm(2)/m2 (<= 0.70 if obese: body mass index >= 30 kg/m(2)) and severe if EOAi <= 0.65 cm(2)/m(2) (<= 0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. RESULTS The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. CONCLUSIONS EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. (C) 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1466 / 1477
页数:12
相关论文
共 50 条
  • [41] Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement
    Mohty, Dania
    Dumesnil, Jean G.
    Echahidi, Najmeddine
    Mathieu, Patrick
    Dagenais, Francois
    Voisine, Pierre
    Pibarot, Philippe
    CIRCULATION, 2007, 116 (16) : 712 - 712
  • [42] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Lower the Guard or Stay Alert?
    Ternacle, Julien
    Theron, Alexis
    Pibarot, Philippe
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2636 - 2638
  • [43] Prosthesis-Patient Mismatch Based on Energy Loss Index After Transcatheter Aortic Valve Replacement
    Okuno, Taishi
    Pilgrim, Thomas
    Heg, Dik
    Stortecky, Stefan
    Praz, Fabien
    Windecker, Stephan
    Lanz, Jonas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) : 2584 - 2586
  • [44] Prosthesis-patient Mismatch Affects Long-term Survival After Aortic Valve Replacement
    Ennker, Juergen
    Albert, Alexander
    Boening, Andreas
    Ennker, Ina C.
    Florath, Ines
    CIRCULATION, 2010, 122 (21)
  • [45] Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: A New Technology With an Old Problem
    Ortoleva, Jamel P.
    Gonzalez-Ciccarelli, Luis F.
    Kawabori, Masashi
    Cobey, Frederick C.
    Resor, Charles D.
    Shapeton, Alexander D.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (08) : 2253 - 2255
  • [46] Prosthesis-Patient Mismatch after Surgical Aortic Valve Replacement: Neither Uncommon nor Harmless
    Rayol, Sergio da Costa
    Barros Oliveira Sa, Michel Pompeu
    Pereira Cavalcanti, Luiz Rafael
    Santos Saragiotto, Felipe Augusto
    Silva Diniz, Roberto Gouvea
    Correia de Araujo e Sa, Frederico Browne
    Menezes, Alexandre Motta
    Vasconcelos Silva, Frederico Pires
    Lima, Ricardo Carvalho
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (03) : 361 - 365
  • [47] Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement
    Mohty, D.
    Dumesnil, J. G.
    Echahidi, N.
    Mathieu, P.
    Dagenais, F.
    Voisine, P.
    Pibarot, P.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 259C - 259C
  • [48] The impact of prosthesis-patient mismatch after aortic valve replacement varies according to age at operation
    Price, Joel
    Toeg, Hadi
    Lam, Buu-Khanh
    Lapierre, Harry
    Mesana, Thierry G.
    Ruel, Marc
    HEART, 2014, 100 (14) : 1099 - 1106
  • [49] Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity
    Airhart, Sophia
    Medvedev, Ivan
    Dean, Larry S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 341 - 345
  • [50] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement It Is Neither Rare Nor Benign
    Pibarot, Philippe
    Clavel, Marie-Annick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2712 - 2716