Transcritical CO2 commercial refrigeration plant with adiabatic gas cooler and subcooling via HVAC: Field tests and modelling

被引:16
|
作者
Cortella, G. [1 ]
D'Agaro, P. [1 ]
Coppola, M. A. [1 ]
机构
[1] Univ Udine, DPIA, Udine, Italy
关键词
CO2; Field measurements; Modeling; Subcooling; Adiabatic Cooling; Commercial Refrigeration; ENERGY; PERFORMANCE; CYCLES; WARM;
D O I
10.1016/j.ijrefrig.2019.11.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Subcooling methods at the exit of the gas cooler in transcritical CO2 commercial refrigeration systems have been studied in the recent years showing that overall remarkable improvements can be obtained. Another strategy that results efficient is the use of evaporative systems at the gas cooler (adiabatic cooling) as it allows to significantly reduce the refrigerant quality at the liquid receiver and to lower the heat rejection pressure. In this work, a fully instrumented CO2 transcritical booster system with parallel compression, in operation in a small size supermarket in northern Italy, made available measured data of its performance when subcooling and/or adiabatic cooling are active. The plant operates in a mild climate, where it suffers operation at transcritical conditions for most of the year. Subcooling in this plant is performed by coupling the refrigeration system with the HVAC system. Taking advantage of experimental measurements, a model in the TRNSYS environment is validated and allows the prediction of the annual plant performance when these strategies are adopted. The adiabatic cooling showed to allow a significant reduction (about 10%) in the energy use, and makes unnecessary the use of a parallel compressor. Subcooling by the HVAC gives rise to a reduced saving (2.9%) due to the absence of a dedicated mechanical subcooler, however it is almost comparable to parallel compression. These trends are confirmed in two other hot and humid climates. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [31] Experimental assessment of a thermoelectric subcooler included in a transcritical CO2 refrigeration plant
    Aranguren, P.
    Sanchez, D.
    Casi, A.
    Cabello, R.
    Astrain, D.
    APPLIED THERMAL ENGINEERING, 2021, 190
  • [32] NUMERICAL ANALYSIS OF CO2 TRANSIENT BEHAVIOR IN THE GAS COOLER DURING VARIABLE START-UP CONDITIONS OF A TRANSCRITICAL REFRIGERATION SYSTEM
    Ituna-Yudonago, J. F.
    Belman-Flores, J. M.
    Elizalde-Blancas, F.
    Perez-Garcia, V.
    Garcia-Valladares, O.
    Carvajal-Mariscal, I.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2019, 18 (03): : 1101 - 1118
  • [33] Experimental assessment of dedicated and integrated mechanical subcooling systems vs parallel compression in transcritical CO2 refrigeration plants
    Nebot-Andres, Laura
    Calleja-Anta, Daniel
    Sanchez, Daniel
    Cabello, Ramon
    Llopis, Rodrigo
    ENERGY CONVERSION AND MANAGEMENT, 2022, 252
  • [34] Energy, exergy, and economic analysis of a novel solar-assisted ejector subcooling CO2 transcritical refrigeration systemt
    Yin, Tailan
    Yang, Qichao
    Jiang, Jiawei
    Zheng, Zeye
    Zhao, Yuanyang
    Liu, Guangbin
    Li, Liansheng
    SOLAR ENERGY, 2024, 284
  • [35] Performance analysis of two-stage compression transcritical CO2 refrigeration system with 8290 mechanical subcooling unit
    Liu, Shengchun
    Lu, Fenping
    Dai, Baomin
    Nian, Victor
    Li, Hailong
    Qi, Haifeng
    Li, Jiayu
    ENERGY, 2019, 189
  • [36] Experimental assessment of different extraction points for the integrated mechanical subcooling system of a CO2 transcritical plant
    Nebot-Andres, Laura
    Calleja-Anta, Daniel
    Fossi, Carlos
    Cabello, Ramon
    Llopis, Rodrigo
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 8 - 16
  • [37] Performance analysis of gas-cooler in automotive CO2 refrigeration system
    Chen, JP
    Mu, JY
    Liu, JP
    Chen, ZJ
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 363 - 367
  • [38] Entropy generation analysis of fan-supplied gas cooler within the framework of two-stage CO2 transcritical refrigeration cycle
    Li, Wenhua
    Xuan, Shenglan
    Sun, Jian
    ENERGY CONVERSION AND MANAGEMENT, 2012, 62 : 93 - 101
  • [39] CO2 with Mechanical Subcooling vs. CO2 Cascade Cycles for Medium Temperature Commercial Refrigeration Applications Thermodynamic Analysis
    Nebot-Andres, Laura
    Llopis, Rodrigo
    Sanchez, Daniel
    Catalan-Gil, Jesus
    Cabello, Ramon
    APPLIED SCIENCES-BASEL, 2017, 7 (09):
  • [40] Performance investigation of the CO2 gas cooler designs and its integration with the refrigeration system
    Tsamos, K. M.
    Gullo, P.
    Ge, Y. T.
    IDew
    Santosa
    Tassou, S. A.
    Hafner, A.
    PROCEEDINGS OF 1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS (ICFES 2017), INCLUDING SYMPOSIUM ON HEAT RECOVERY AND EFFICIENT CONVERSION AND UTILISATION OF WASTE HEAT, 2017, 123 : 265 - 272