Transcritical CO2 commercial refrigeration plant with adiabatic gas cooler and subcooling via HVAC: Field tests and modelling

被引:16
|
作者
Cortella, G. [1 ]
D'Agaro, P. [1 ]
Coppola, M. A. [1 ]
机构
[1] Univ Udine, DPIA, Udine, Italy
关键词
CO2; Field measurements; Modeling; Subcooling; Adiabatic Cooling; Commercial Refrigeration; ENERGY; PERFORMANCE; CYCLES; WARM;
D O I
10.1016/j.ijrefrig.2019.11.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Subcooling methods at the exit of the gas cooler in transcritical CO2 commercial refrigeration systems have been studied in the recent years showing that overall remarkable improvements can be obtained. Another strategy that results efficient is the use of evaporative systems at the gas cooler (adiabatic cooling) as it allows to significantly reduce the refrigerant quality at the liquid receiver and to lower the heat rejection pressure. In this work, a fully instrumented CO2 transcritical booster system with parallel compression, in operation in a small size supermarket in northern Italy, made available measured data of its performance when subcooling and/or adiabatic cooling are active. The plant operates in a mild climate, where it suffers operation at transcritical conditions for most of the year. Subcooling in this plant is performed by coupling the refrigeration system with the HVAC system. Taking advantage of experimental measurements, a model in the TRNSYS environment is validated and allows the prediction of the annual plant performance when these strategies are adopted. The adiabatic cooling showed to allow a significant reduction (about 10%) in the energy use, and makes unnecessary the use of a parallel compressor. Subcooling by the HVAC gives rise to a reduced saving (2.9%) due to the absence of a dedicated mechanical subcooler, however it is almost comparable to parallel compression. These trends are confirmed in two other hot and humid climates. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [1] Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling
    Llopis, Rodrigo
    Nebot-Andres, Laura
    Cabello, Ramon
    Sanchez, Daniel
    Catalan-Gil, Jesus
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 361 - 368
  • [2] Field tests, model validation and performance of a CO2 commercial refrigeration plant integrated with HVAC system
    D'Agaro, R.
    Coppola, M. A.
    Cortella, G.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 380 - 391
  • [3] Experimental determination of the optimum intermediate and gas-cooler pressures of a commercial transcritical CO2 refrigeration plant with parallel compression
    Nebot-Andres, Laura
    Sanchez, Daniel
    Calleja-Anta, Daniel
    Cabello, Ramon
    Llopis, Rodrigo
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [4] Experimental evaluation of transcritical CO2 refrigeration with mechanical subcooling
    Bush, John
    Beshr, Mohamed
    Aute, Vikrant
    Radermacher, Reinhard
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (06) : 1013 - 1025
  • [5] SIMULATIONS AND FIELD TESTS OF A CO2 REFRIGERATING PLANT FOR COMMERCIAL REFRIGERATION
    Cortella, G.
    D'Agaro, P.
    Coppola, M. A.
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 556 - 563
  • [6] THE OPTIMUM GAS COOLER PRESSURE FOR TRANSCRITICAL CO2 REFRIGERATION CYCLE: A NEW CORRELATION
    Oezguer, Arif Emre
    Bayrakci, Hilmi Cenk
    Akdag, Ali Ekrem
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2009, 29 (02) : 23 - 28
  • [7] Experimental determination of the optimum working conditions of a transcritical CO2 refrigeration plant with integrated mechanical subcooling
    Nebot-Andres, Laura
    Catalan-Gil, Jesus
    Sanchez, Daniel
    Calleja-Anta, Daniel
    Cabello, Ramon
    Llopis, Rodrigo
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 : 266 - 275
  • [8] Improvements in the cooling capacity and the COP of a transcritical CO2 refrigeration plant operating with a thermoelectric subcooling system
    Astrain, D.
    Merino, A.
    Catalan, L.
    Aranguren, P.
    Araiz, M.
    Sanchez, D.
    Cabello, R.
    Llopis, R.
    APPLIED THERMAL ENGINEERING, 2019, 155 : 110 - 122
  • [9] Experimental determination of the optimum working conditions of a commercial transcritical CO2 refrigeration plant with a R-152a dedicated mechanical subcooling.
    Nebot-Andres, Laura
    Sanchez, Daniel
    Calleja-Anta, Daniel
    Cabello, Ramon
    Llopis, Rodrigo
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 121 : 258 - 268
  • [10] EXPERIMENTAL EVALUATION OF A DEDICATED MECHANICAL SUBCOOLING SYSTEM IN A CO2 TRANSCRITICAL REFRIGERATION CYCLE
    Nebot-Andres, L.
    Llopis, R.
    Sanchez, D.
    Cabello, R.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 965 - 972