Ultraviolet laser-induced fluorescence detection strategies in capillary electrophoresis: determination of naphthalene sulphonates in river water

被引:30
|
作者
Kok, SJ [1 ]
Isberg, ICK [1 ]
Gooijer, C [1 ]
Brinkman, UAT [1 ]
Velthorst, NH [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
capillary electrophoresis; UV laser; dye laser; emission spectra; environmental analysis; aromatic sulphonates;
D O I
10.1016/S0003-2670(97)00707-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various UV-laser-induced fluorescence detection strategies for capillary electrophoresis (CE) are compared, i.e. two UV-laser systems (a pulsed laser providing up to 25 mW of tunable emission, applied at 280, 290 and 325 nm, and a continuous wave (CW) laser providing up to 100 mW of 257 nm emission) and different methods to collect the fluorescence emission signal and to reduce the background. Attention is focused on the determination of amino-and hydroxy-substituted naphthalene sulphonates (NS) in river water; these analytes exhibit native fluorescence upon UV excitation. Optimum results were obtained by applying only a minor portion of the available (average) laser powers, viz. 0.7 mW at 280 nm for the pulsed laser, and 5 mW for the cw laser. For emission collection, the most favourable results were obtained with a mirror-based microscope objective, which facilitates efficient spatial filtering and does not produce impurity fluorescence upon UV-laser irradiation. For standard solutions, the cw laser gave around 20-fold better detection limits (10(-9)-10(-10) M) than the pulsed laser. For river water, excitation of interferences (presumably humic acids, which exhibit native fluorescence) could be much better suppressed if the pulsed laser was used with selective excitation at 280 nm. Therefore, for real-sample analysis the latter combination is to be preferred. The set-up was used for the identification and quantification (at the 1-35 mu g l(-1) level) of NS in a river Elbe sample. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [31] Sensitive determination of fluoroquinolone residues in waters by capillary electrophoresis with laser-induced fluorescence detection
    Lombardo-Aguei, Manuel
    Gamiz-Gracia, Laura
    Garcia-Campana, Ana M.
    Cruces-Blanco, Carmen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (04) : 1551 - 1557
  • [32] Sensitive determination of fluoroquinolone residues in waters by capillary electrophoresis with laser-induced fluorescence detection
    Manuel Lombardo-Agüí
    Laura Gámiz-Gracia
    Ana M. García-Campaña
    Carmen Cruces-Blanco
    Analytical and Bioanalytical Chemistry, 2010, 396 : 1551 - 1557
  • [33] YOCTOMOLE DETECTION LIMIT BY LASER-INDUCED FLUORESCENCE IN CAPILLARY ELECTROPHORESIS
    CHEN, DY
    DOVICHI, NJ
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 657 (02): : 265 - 269
  • [34] Biomedical applications of capillary electrophoresis with laser-induced fluorescence detection
    Páez, X
    Hernández, L
    BIOPHARMACEUTICS & DRUG DISPOSITION, 2001, 22 (7-8) : 273 - 289
  • [35] The Immunoassay of Methotrexate by Capillary Electrophoresis with Laser-induced Fluorescence Detection
    Yoshio Suzuki
    Hidetoshi Arakawa
    Masako Maeda
    Analytical Sciences, 2003, 19 : 111 - 115
  • [36] Determination of the cardiolipin content of individual mitochondria by capillary electrophoresis with laser-induced fluorescence detection
    Fuller, KM
    Duffy, CF
    Arriaga, EA
    ELECTROPHORESIS, 2002, 23 (11) : 1571 - 1576
  • [37] Determination of metoprolol in rabbit blood using capillary electrophoresis with laser-induced fluorescence detection
    Chen, Yu Yun
    Yang, Wei Ping
    Zhang, Zhu Jun
    CHINESE CHEMICAL LETTERS, 2011, 22 (03) : 350 - 353
  • [38] The immunoassay of methotrexate by capillary electrophoresis with laser-induced fluorescence detection
    Suzuki, Y
    Arakawa, H
    Maeda, M
    ANALYTICAL SCIENCES, 2003, 19 (01) : 111 - 115
  • [39] Determination of morphine by capillary zone electrophoresis immunoassay combined with laser-induced fluorescence detection
    Mi, JQ
    Zhang, XX
    Chang, WB
    JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2004, 25 (01): : 57 - 70
  • [40] Determination of Gabapentin in Human Plasma and Urine by Capillary Electrophoresis with Laser-Induced Fluorescence Detection
    Lin, Xia
    Cai, Yuanli
    Yan, Jin
    Zhang, Lili
    Wu, Di
    Li, Hui
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (06) : 986 - 992