The Gillings Sampler - An electrostatic air sampler as an alternative method for aerosol in vitro exposure studies

被引:22
|
作者
Zavala, Jose [1 ]
Lichtveld, Kim [1 ]
Ebersviller, Seth [1 ]
Carson, Johnny L. [2 ,3 ]
Walters, Glenn W. [1 ]
Jaspers, Ilona [1 ,2 ,3 ]
Jeffries, Harvey E. [1 ]
Sexton, Kenneth G. [1 ]
Vizuete, William [1 ]
机构
[1] Univ N Carolina, Dept Environm Sci & Engn, Chapel Hill, NC 27515 USA
[2] Univ N Carolina, Dept Pediat, Chapel Hill, NC 27515 USA
[3] Univ N Carolina, Ctr Environm Med & Lung Biol, Chapel Hill, NC 27515 USA
关键词
Air-liquid interface exposures; Electrostatic air sampler; Aerosol toxicity; PARTICULATE MATTER; CELL EXPOSURE; INFLAMMATORY RESPONSES; EPITHELIAL-CELLS; SYSTEM; OZONE; DEPOSITION; PRECIPITATOR; COLLECTION; EXPRESSION;
D O I
10.1016/j.cbi.2014.06.026
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There is growing interest in studying the toxicity and health risk of exposure to multi-pollutant mixtures found in ambient air, and the U. S. Environmental Protection Agency (EPA) is moving towards setting standards for these types of mixtures. Additionally, the Health Effects Institute's strategic plan aims to develop and apply next-generation multi-pollutant approaches to understanding the health effects of air pollutants. There's increasing concern that conventional in vitro exposure methods are not adequate to meet EPA's strategic plan to demonstrate a direct link between air pollution and health effects. To meet the demand for new in vitro technology that better represents direct air-to-cell inhalation exposures, a new system that exposes cells at the air-liquid interface was developed. This new system, named the Gillings Sampler, is a modified two-stage electrostatic precipitator that provides a viable environment for cultured cells. Polystyrene latex spheres were used to determine deposition efficiencies (38-45%), while microscopy and imaging techniques were used to confirm uniform particle deposition. Negative control A549 cell exposures indicated the sampler can be operated for up to 4 h without inducing any significant toxic effects on cells, as measured by lactate dehydrogenase (LDH) and interleukin-8 (IL-8). A novel positive aerosol control exposure method, consisting of a p-tolualdehyde (TOLALD) impregnated mineral oil aerosol (MOA), was developed to test this system. Exposures to the toxic MOA at a 1 ng/cm(2) dose of TOLALD yielded a reproducible 1.4 and 2-fold increase in LDH and IL-8 mRNA levels over controls. This new system is intended to be used as an alternative research tool for aerosol in vitro exposure studies. While further testing and optimization is still required to produce a "commercially ready" system, it serves as a stepping-stone in the development of cost-effective in vitro technology that can be made accessible to researchers in the near future. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:158 / 168
页数:11
相关论文
共 50 条
  • [21] Alternative method for airborne virus detection in only few hours innovative microbial air sampler
    Desjonqueres, Q.
    JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S7 - S7
  • [22] Investigation of a New Electrostatic Sampler for Concentrating Biological and Non-Biological Aerosol Particles
    Roux, Jean-Maxime
    Kaspari, Oliver
    Heinrich, Renate
    Hanschmann, Nicole
    Grunow, Roland
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (05) : 463 - 471
  • [23] Design and Testing of Electrostatic Aerosol In Vitro Exposure System (EAVES): An Alternative Exposure System for Particles
    de Bruijne, K.
    Ebersviller, S.
    Sexton, K. G.
    Lake, S.
    Leith, D.
    Goodman, R.
    Jetters, J.
    Walters, G. W.
    Doyle-Eisele, M.
    Woodside, R.
    Jeffries, H. E.
    Jaspers, I.
    INHALATION TOXICOLOGY, 2009, 21 (02) : 91 - 101
  • [24] POWDER INHALATION AEROSOL STUDIES .2. INVITRO RAT LUNG MODEL AND ITS COMPARISONS WITH THE AIR SAMPLER
    CHOWHAN, ZT
    LINN, EE
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1979, 3 (2-3) : 117 - 126
  • [25] An environmental air sampler to evaluate personal exposure to volatile organic compounds
    Rajapakse, Maneeshin Y.
    Borras, Eva
    Fung, Alexander G.
    Yeap, Danny
    McCartney, Mitchell M.
    Fabia, Fauna M.
    Kenyon, Nicholas J.
    Davis, Cristina E.
    ANALYST, 2021, 146 (02) : 636 - 645
  • [26] A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets
    Foat, T. G.
    Sellors, W. J.
    Walker, M. D.
    Rachwal, P. A.
    Jones, J. W.
    Despeyroux, D. D.
    Coudron, L.
    Munro, I.
    McCluskey, D. K.
    Tan, C. K. L.
    Tracey, M. C.
    JOURNAL OF AEROSOL SCIENCE, 2016, 95 : 43 - 53
  • [27] Development of PM0.1 Personal Sampler for Evaluation of Personal Exposure to Aerosol Nanoparticles
    Thongyen, Thunyapat
    Hata, Mitsuhiko
    Toriba, Akira
    Ikeda, Takuji
    Koyama, Hiromi
    Otani, Yoshio
    Furuuchi, Masami
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (01) : 180 - 187
  • [28] A Headset-Mounted Mini Sampler for Measuring Exposure to Welding Aerosol in the Breathing Zone
    Liden, Goran
    Surakka, Jouni
    ANNALS OF OCCUPATIONAL HYGIENE, 2009, 53 (02): : 99 - 116
  • [29] Review of Workplace Based Aerosol Sampler Comparison Studies, 2004-2020
    Hanlon, James
    Galea, Karen S.
    Verpaele, Steven
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [30] Novel Virus Air Sampler Based on Electrostatic Precipitation and Air Sampling of SARS-CoV-2
    Fukuda, Kyohei
    Baba, Hiroaki
    Yoshida, Mie
    Kitabayashi, Kouichi
    Katsushima, Shinjirou
    Sonehara, Hiroki
    Mizuno, Kazue
    Kanamori, Hajime
    Tokuda, Koichi
    Nakagawa, Atsuhiro
    Mizuno, Akira
    MICROORGANISMS, 2023, 11 (04)