Comparative analysis of aneurysm volume by different methods based on angiography and computed tomography angiography

被引:10
|
作者
Escobar-de la Garma, Victor Hugo [1 ]
Zenteno, Marco [1 ]
Padilla-Vazquez, Felipe [1 ]
San-Juan, Daniel [2 ]
Ceron-Morales, Aurelio [1 ]
机构
[1] Inst Nacl Neurol & Neurocirugia Manuel Velasco Su, Neuroendovasc Therapy Dept, Ave Insurgentes Sur 3877, Mexico City 14269, DF, Mexico
[2] Inst Nacl Neurol & Neurocirugia Manuel Velasco Su, Dept Clin Res, Mexico City, DF, Mexico
关键词
Aneurysm; Volume; Digital subtraction angiography; Computed tomography; Packing density; Angiogram; DIGITAL-SUBTRACTION-ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; MR-ANGIOGRAPHY; CT ANGIOGRAPHY; PACKING; COILS; APPROXIMATION;
D O I
10.1007/s10143-018-0943-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Endovascular treatment and prognosis of intracranial aneurysms are based on size and volume, which demand more accurate neuroimaging techniques. Aneurysm volume calculation is important to choose endovascular treatment modalities and packing density calculation. Of all these methods, it remains unknown which one is the most accurate to calculate aneurysm volume. The objective of this study is to compare the accuracy of three angiography-based versus three tomographic-based methods which calculate aneurysm volume. A retrospective study which included patients with ruptured and unruptured cerebral aneurysms diagnosed by angiogram and computed tomography angiography (CTA) was done. The accuracy of each method was assessed with an ellipsoid glass model of known volume, which helped us to adjust variation in volumetric measurements done with AngioSuite (c) and AngioCalc (c) softwares (based on angiographic and tomographic images), 3D-rotational angiography and 3D-CTA (tridimensional computed tomography angiography), based on measurements of diameters such as maximal width and maximal height. Descriptive statistics, ANOVA for repetitive samples and t test were used. We included 89 patients (126 saccular intracraneal aneurysms). AngioSuite (c) software (angiography-based) showed more accuracy compared to other methods in our control model. The geometric system (AngioCalc) based on CTA images was statistically different from all other methods studied. AngioCalc (CTA-based) demonstrated a significant difference compared with other methods hence, it may overestimate volume measurements. AngioSuite (c) software measurements (angiography-based) may be the most accurate method to calculate aneurysm volume.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 50 条
  • [21] Coronary computed tomography angiography
    Chang, Su M.
    Bhatti, Sabha
    Nabi, Faisal
    CURRENT OPINION IN CARDIOLOGY, 2011, 26 (05) : 392 - 402
  • [22] Coronary Computed Tomography Angiography
    Feger, Sarah
    Dewey, Marc
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 324 (14): : 1455 - 1456
  • [23] Computed tomography coronary angiography
    Achenbach, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 1919 - 1928
  • [24] A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography
    Mishra, Saurav
    Mishra, Sandeep
    Regmi, Sabina
    Gupta, Vivek
    NEURORADIOLOGY JOURNAL, 2024, 37 (02): : 221 - 228
  • [25] Computed Tomography Angiography Reply
    Troebs, Monique
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2019, 116 (26): : 460 - 461
  • [26] Coronary Computed Tomography Angiography
    Rumberger, John A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) : 1733 - 1735
  • [27] Coronary computed tomography angiography
    Grunau, Gilat
    Leipsic, Jonathon
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2016, 188 (02) : 139 - 139
  • [28] Sensitivity of Computed Tomography Angiography vs Catheter Angiography in the Detection of a Ruptured Intracranial Infectious Aneurysm in a Pregnant Woman
    Sun, Lin-Quan
    Slivka, Andrew P.
    ARCHIVES OF NEUROLOGY, 2012, 69 (02) : 270 - 271
  • [29] Whole-Heart Coronary Angiography using Volume Computed Tomography in Comparison to Conventional Coronary Angiography
    Dewey, Marc
    Zimmermann, Elike
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [30] Consistency of quantitative analysis of coronary computed tomography angiography
    Lee, Sang-Eun
    Park, Hyung-Bok
    Xuan, Dongchun
    Lee, Byoung Kwon
    Hong, Myeong-Ki
    Jang, Yangsoo
    Chang, Hyuk-Jae
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) : 48 - 54