Repeatability, Reproducibility, and Accuracy of Quantitative MRI of the Breast in the Community Radiology Setting

被引:27
|
作者
Sorace, Anna G. [1 ,2 ,3 ]
Wu, Chengyue [3 ]
Barnes, Stephanie L. [3 ,4 ]
Jarrett, Angela M. [4 ]
Avery, Sarah [5 ]
Patt, Debra [6 ]
Goodgame, Boone [7 ,8 ]
Luci, Jeffery J. [3 ,9 ]
Kang, Hakmook [10 ]
Abramson, Richard G. [11 ]
Yankeelov, Thomas E. [1 ,2 ,3 ,4 ]
Virostko, John [1 ,2 ]
机构
[1] Univ Texas Austin, Dept Diagnost Med, Austin, TX 78712 USA
[2] Univ Texas Austin, Livestrong Canc Inst, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Inst Computat Engn & Sci, Austin, TX 78712 USA
[5] Austin Radiol Assoc, Austin, TX USA
[6] Texas Oncol, Austin, TX USA
[7] Seton Hosp, Austin, TX USA
[8] Univ Texas Austin, Dept Internal Med, Austin, TX 78712 USA
[9] Univ Texas Austin, Dept Neurosci, Austin, TX 78712 USA
[10] Vanderbilt Univ, Med Ctr, Dept Biostat, Nashville, TN USA
[11] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN USA
关键词
APPARENT DIFFUSION-COEFFICIENT; ICE-WATER PHANTOM; NEOADJUVANT CHEMOTHERAPY; PATHOLOGICAL RESPONSE; MENSTRUAL-CYCLE; CLINICAL-TRIALS; DCE-MRI; T; CANCER; THERAPY;
D O I
10.1002/jmri.26011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitative diffusion-weighted MRI (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) have the potential to impact patient care by providing noninvasive biological information in breast cancer. Purpose/Hypothesis: To quantify the repeatability, reproducibility, and accuracy of apparent diffusion coefficient (ADC) and T1-mapping of the breast in community radiology practices. Study Type: Prospective. Subjects/Phantom: Ice-water DW-MRI and T1 gel phantoms were used to assess accuracy. Normal subjects (n53) and phantoms across three sites (one academic, two community) were used to assess reproducibility. Test-retest analysis at one site in normal subjects (n512) was used to assess repeatability. Field Strength/Sequence: 3T Siemens Skyra MRI quantitative DW-MRI and T1-mapping. Assessment: Quantitative DW-MRI and T1-mapping parametric maps of phantoms and fibroglandular and adipose tissue of the breast. Statistical Tests: Average values of breast tissue were quantified and Bland-Altman analysis was performed to assess the repeatability of the MRI techniques, while the Friedman test assessed reproducibility. Results: ADC measurements were reproducible across sites, with an average difference of 1.6% in an ice-water phantom and 7.0% in breast fibroglandular tissue. T1 measurements in gel phantoms had an average difference of 2.8% across three sites, whereas breast fibroglandular and adipose tissue had 8.4% and 7.5% average differences, respectively. In the repeatability study, we found no bias between first and second scanning sessions (P50.1). The difference between repeated measurements was independent of the mean for each MRI metric (P50.156, P50.862, P50.197 for ADC, T1 of fibroglandular tissue, and T1 of adipose tissue, respectively). Data Conclusion: Community radiology practices can perform repeatable, reproducible, and accurate quantitative T1mapping and DW-MRI. This has the potential to dramatically expand the number of sites that can participate in multisite clinical trials and increase clinical translation of quantitative MRI techniques for cancer response assessment. Level of Evidence: 1 Technical Efficacy: Stage 2
引用
收藏
页码:695 / 707
页数:13
相关论文
共 50 条
  • [41] Reproducibility of quantitative structural and physiological MRI measurements
    McGuire, Stephen A.
    Wijtenburg, S. Andrea
    Sherman, Paul M.
    Rowland, Laura M.
    Ryan, Meghann
    Sladky, John H.
    Kochunov, Peter V.
    BRAIN AND BEHAVIOR, 2017, 7 (09):
  • [42] QUALITY ASSURANCE IMPROVES ACCURACY OF MRI PROSTATE CANCER DETECTION IN A COMMUNITY BASED SETTING
    Liaw, Christine
    Kaplan, Steven A.
    Rastinehad, Ardeshir
    Olsson, Carl
    Latino, Kathleen
    Kapoor, Deepak
    JOURNAL OF UROLOGY, 2020, 203 : E987 - E988
  • [43] Repeatability, reproducibility, and accuracy of a novel imaging technique for measurement of ocular axial length
    Hari, Neelam
    Burgess, Carrie
    Vaghefi, Ehsan
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [44] Proton density fat fraction MRI of vertebral bone marrow: Accuracy, repeatability, and reproducibility among readers, field strengths, and imaging platforms
    Schmeel, Frederic Carsten
    Vomweg, Toni
    Traeber, Frank
    Gerhards, Arnd
    Enkirch, Simon Jonas
    Faron, Anton
    Sprinkart, Alois Martin
    Schmeel, Leonard Christopher
    Luetkens, Julian Alexander
    Thomas, Daniel
    Kukuk, Guido Matthias
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) : 1762 - 1772
  • [45] Editorial for "Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver"
    Wetscherek, Andreas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1704 - 1705
  • [46] Enhancing the Clinical Utility of Radiomics: Addressing the Challenges of Repeatability and Reproducibility in CT and MRI
    Teng, Xinzhi
    Wang, Yongqiang
    Nicol, Alexander James
    Ching, Jerry Chi Fung
    Wong, Edwin Ka Yiu
    Lam, Kenneth Tsz Chun
    Zhang, Jiang
    Lee, Shara Wee-Yee
    Cai, Jing
    DIAGNOSTICS, 2024, 14 (16)
  • [47] Myelin quantification with MRI: A systematic review of accuracy and reproducibility
    van der Weijden, Chris W. J.
    Garcia, David Vallez
    Borra, Ronald J. H.
    Thurner, Patrick
    Meilof, Jan F.
    van Laar, Peter-Jan
    Dierckx, Rudi A. J. O.
    Gutmann, Ingomar W.
    de Vries, Erik F. J.
    NEUROIMAGE, 2021, 226
  • [48] Reproducibility of quantitative sensory testing in the clinical trial setting
    Peltier, AC
    Singleton, JR
    Goldstein, J
    Howard, JR
    Smith, AG
    Feldman, EL
    Russell, JW
    ANNALS OF NEUROLOGY, 2004, 56 : S60 - S60
  • [49] Repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) in pregnancy
    Mlodawski, Jakub
    Mlodawska, Marta
    Plusajska, Justyna
    Detka, Karolina
    Michalska, Agata
    Swiercz, Grzegorz
    Sikorski, Marek
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] Repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) in pregnancy
    Jakub Mlodawski
    Marta Mlodawska
    Justyna Plusajska
    Karolina Detka
    Agata Michalska
    Grzegorz Swiercz
    Marek Sikorski
    Scientific Reports, 11