Atomization of liquids in a Pease-Anthony!Venturi Scrubber -: Part II.: Droplet dispersion

被引:26
|
作者
Gonçalves, JAS [1 ]
Costa, MAM [1 ]
Aguiar, ML [1 ]
Coury, JR [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem Engn, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Venturi scrubbers; droplet dispersion; gas cleaning;
D O I
10.1016/j.jhazmat.2004.08.030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Droplet distribution is of fundamental importance to the performance of a Venturi scrubber. Ensuring good liquid distribution can increase performance at minimal liquid usage. In this study, droplet dispersion in a rectangular Pease-Anthony Venturi scrubber, operating horizontally, was examined both theoretically and experimentally. The Venturi throat cross-section was 24 mm x 35 turn, and the throat length varied from 63 to 140 mm. Liquid was injected through a single orifice (1.0 mm, diameter) on the throat wall. This arrangement allowed the study of the influence of jet penetration on droplet distribution. Gas velocity at the throat was 58.3 and 74.6 m/s, and the liquid flow rate was 286, 559 and 853 ml/min. A probe with a 2.7 mm internal diameter was used to isokinetically remove liquid from several positions inside the equipment. It was possible to study liquid distribution close to the injection point. A new model for droplet dispersion, which incorporates the new description of the jet atomization process developed by the present authors in the first article of this series, is proposed and evaluated. The model predicted well the experimental data. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:147 / 157
页数:11
相关论文
共 50 条