Correlation of X-Ray Dark-Field Radiography to Mechanical Sample Properties

被引:8
|
作者
Malecki, Andreas [1 ,2 ]
Eggl, Elena [1 ,2 ]
Schaff, Florian [1 ,2 ]
Potdevin, Guillaume [1 ,2 ]
Baum, Thomas [3 ]
Garcia, Eduardo Grande [3 ]
Bauer, Jan S. [4 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, IMETUM Zentralinst Med Tech, D-85748 Garching, Germany
[3] Tech Univ Munich, Inst Radiol, Klinikum Rechts Isar, D-81675 Munich, Bavaria, Germany
[4] Tech Univ Munich, Abt Neuroradiol, Klinikum Rechts Isar, D-81675 Munich, Bavaria, Germany
基金
欧洲研究理事会;
关键词
grating interferometry; directional dark-field imaging; mechanical testing; Young's modulus; average anisotropy; GRATING INTERFEROMETER; CONTRAST;
D O I
10.1017/S1431927614001718
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The directional dark-field signal obtained with X-ray grating interferometry yields direction-dependent information about the X-ray scattering taking place inside the examined sample. It allows examination of its morphology without the requirement of resolving the micrometer size structures directly causing the scattering. The local morphology in turn gives rise to macroscopic mechanical properties of the investigated specimen. In this study, we investigate the relation between the biomechanical elasticity (Young's modulus) and the measured directional dark-field parameters of a well-defined sample made of wood. In our proof-of-principle experiment, we found a correlation between Young's modulus, the average dark-field signal, and the average dark-field anisotropy. Hence, we are able to show that directional dark-field imaging is a new method to predict mechanical sample properties. As grating interferometry provides absorption, phase-contrast, and dark-field data at the same time, this technique appears promising to combine imaging and mechanical testing in a single testing stage. Therefore, we believe that directional dark-field imaging will have a large impact in the materials science world.
引用
收藏
页码:1528 / 1533
页数:6
相关论文
共 50 条
  • [21] Correlation of image quality parameters with tube voltage in X-ray dark-field chest radiography: a phantom study
    Andreas P. Sauter
    Jana Andrejewski
    Manuela Frank
    Konstantin Willer
    Julia Herzen
    Felix Meurer
    Alexander A. Fingerle
    Markus R. Makowski
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 11
  • [22] Correlation of image quality parameters with tube voltage in X-ray dark-field chest radiography: a phantom study
    Sauter, Andreas P.
    Andrejewski, Jana
    Frank, Manuela
    Willer, Konstantin
    Herzen, Julia
    Meurer, Felix
    Fingerle, Alexander A.
    Makowski, Markus R.
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [23] X-ray dark-field radiography facilitates the diagnosis of pulmonary fibrosis in a mouse model
    Katharina Hellbach
    Andre Yaroshenko
    Konstantin Willer
    Thomas M. Conlon
    Margarita B. Braunagel
    Sigrid Auweter
    Ali Ö. Yildirim
    Oliver Eickelberg
    Franz Pfeiffer
    Maximilian F. Reiser
    Felix G. Meinel
    Scientific Reports, 7
  • [24] Quantitative in vivo X-ray dark-field radiography for early pulmonary emphysema diagnosis
    Hellbach, Katharina
    Yaroshenko, Andre
    Meinel, Felix G.
    Bech, Martin
    Eickelberg, Oliver
    Bamberg, Fabian
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Yildirim, Ali O.
    Pfeiffer, Franz
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [25] Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography
    Katharina Hellbach
    Andrea Baehr
    Fabio De Marco
    Konstantin Willer
    Lukas B. Gromann
    Julia Herzen
    Michaela Dmochewitz
    Sigrid Auweter
    Alexander A. Fingerle
    Peter B. Noël
    Ernst J. Rummeny
    Andre Yaroshenko
    Hanns-Ingo Maack
    Thomas Pralow
    Hendrik van der Heijden
    Nataly Wieberneit
    Roland Proksa
    Thomas Koehler
    Karsten Rindt
    Tobias J. Schroeter
    Juergen Mohr
    Fabian Bamberg
    Birgit Ertl-Wagner
    Franz Pfeiffer
    Maximilian F. Reiser
    Scientific Reports, 8
  • [26] Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography
    Hellbach, Katharina
    Baehr, Andrea
    De Marco, Fabio
    Willer, Konstantin
    Gromann, Lukas B.
    Herzen, Julia
    Dmochewitz, Michaela
    Auweter, Sigrid
    Fingerle, Alexander A.
    Noeel, Peter B.
    Rummeny, Ernst J.
    Yaroshenko, Andre
    Maack, Hanns-Ingo
    Pralow, Thomas
    van der Heijden, Hendrik
    Wieberneit, Nataly
    Proksa, Roland
    Koehler, Thomas
    Rindt, Karsten
    Schroeter, Tobias J.
    Mohr, Juergen
    Bamberg, Fabian
    Ertl-Wagner, Birgit
    Pfeiffer, Franz
    Reiser, Maximilian F.
    SCIENTIFIC REPORTS, 2018, 8
  • [27] Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography
    Hellbach, Katharina
    Yaroshenko, Andre
    Willer, Konstantin
    Pritzke, Tina
    Baumann, Alena
    Hesse, Nina
    Auweter, Sigrid
    Reiser, Maximilian F.
    Eickelberg, Oliver
    Pfeiffer, Franz
    Hilgendorff, Anne
    Meinel, Felix G.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 597 - 601
  • [28] Grating-based X-ray dark-field imaging: a new paradigm in radiography
    Yaroshenko A.
    Hellbach K.
    Bech M.
    Grandl S.
    Reiser M.F.
    Pfeiffer F.
    Meinel F.G.
    Current Radiology Reports, 2 (7)
  • [29] Directional x-ray dark-field imaging
    Jensen, Torben H.
    Bech, Martin
    Bunk, Oliver
    Donath, Tilman
    David, Christian
    Feidenhans'i, Robert
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3317 - 3323
  • [30] Trochoidal X-ray Vector Radiography: Directional dark-field without grating stepping
    Sharma, Y.
    Bachche, S.
    Kageyama, M.
    Kuribayashi, M.
    Pfeiffer, F.
    Lasser, T.
    Momose, A.
    APPLIED PHYSICS LETTERS, 2018, 112 (11)