Correlation of X-Ray Dark-Field Radiography to Mechanical Sample Properties

被引:8
|
作者
Malecki, Andreas [1 ,2 ]
Eggl, Elena [1 ,2 ]
Schaff, Florian [1 ,2 ]
Potdevin, Guillaume [1 ,2 ]
Baum, Thomas [3 ]
Garcia, Eduardo Grande [3 ]
Bauer, Jan S. [4 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, IMETUM Zentralinst Med Tech, D-85748 Garching, Germany
[3] Tech Univ Munich, Inst Radiol, Klinikum Rechts Isar, D-81675 Munich, Bavaria, Germany
[4] Tech Univ Munich, Abt Neuroradiol, Klinikum Rechts Isar, D-81675 Munich, Bavaria, Germany
基金
欧洲研究理事会;
关键词
grating interferometry; directional dark-field imaging; mechanical testing; Young's modulus; average anisotropy; GRATING INTERFEROMETER; CONTRAST;
D O I
10.1017/S1431927614001718
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The directional dark-field signal obtained with X-ray grating interferometry yields direction-dependent information about the X-ray scattering taking place inside the examined sample. It allows examination of its morphology without the requirement of resolving the micrometer size structures directly causing the scattering. The local morphology in turn gives rise to macroscopic mechanical properties of the investigated specimen. In this study, we investigate the relation between the biomechanical elasticity (Young's modulus) and the measured directional dark-field parameters of a well-defined sample made of wood. In our proof-of-principle experiment, we found a correlation between Young's modulus, the average dark-field signal, and the average dark-field anisotropy. Hence, we are able to show that directional dark-field imaging is a new method to predict mechanical sample properties. As grating interferometry provides absorption, phase-contrast, and dark-field data at the same time, this technique appears promising to combine imaging and mechanical testing in a single testing stage. Therefore, we believe that directional dark-field imaging will have a large impact in the materials science world.
引用
收藏
页码:1528 / 1533
页数:6
相关论文
共 50 条
  • [1] X-ray Dark-field Chest Radiography of Lymphangioleiomyomatosis
    Gassert, Florian T.
    Pfeiffer, Franz
    RADIOLOGY, 2022, 303 (03) : 499 - 500
  • [2] In-vivo X-ray Dark-Field Chest Radiography of a Pig
    Gromann, Lukas B.
    De Marco, Fabio
    Willer, Konstantin
    Noel, Peter B.
    Scherer, Kai
    Renger, Bernhard
    Gleich, Bernhard
    Achterhold, Klaus
    Fingerle, Alexander A.
    Muenzel, Daniela
    Auweter, Sigrid
    Hellbach, Katharina
    Reiser, Maximilian
    Baehr, Andrea
    Dmochewitz, Michaela
    Schroeter, Tobias J.
    Koch, Frieder J.
    Meyer, Pascal
    Kunka, Danays
    Mohr, Juergen
    Yaroshenko, Andre
    Maack, Hanns-Ingo
    Pralow, Thomas
    van der Heijden, Hendrik
    Proksa, Roland
    Koehler, Thomas
    Wieberneit, Nataly
    Rindt, Karsten
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Herzen, Julia
    SCIENTIFIC REPORTS, 2017, 7
  • [3] PRECLINICAL X-RAY DARK-FIELD RADIOGRAPHY FOR PULMONARY EMPHYSEMA EVALUATION
    Yaroshenko, A.
    Meinel, F. G.
    Bech, M.
    Tapfer, A.
    Velroyen, A.
    Schleede, S.
    Mueller, M.
    Auweter, S.
    Bohla, A.
    Yildirim, A. Oe
    Nikolaou, K.
    Bamberg, F.
    Eickelberg, O.
    Reiser, M.
    Pfeiffer, F.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 370 - 373
  • [4] Optimization of tube voltage in X-ray dark-field chest radiography
    Andreas P. Sauter
    Jana Andrejewski
    Fabio De Marco
    Konstantin Willer
    Lukas B. Gromann
    Wolfgang Noichl
    Fabian Kriner
    Florian Fischer
    Christian Braun
    Thomas Koehler
    Felix Meurer
    Alexander A. Fingerle
    Daniela Pfeiffer
    Ernst Rummeny
    Julia Herzen
    Franz Pfeiffer
    Scientific Reports, 9
  • [5] Frozen and defrosted fruit revealed with X-ray dark-field radiography
    Nielsen, Mikkel Schou
    Christensen, Lars Bager
    Feidenhans'l, Robert
    FOOD CONTROL, 2014, 39 : 222 - 226
  • [6] In-vivo X-ray Dark-Field Chest Radiography of a Pig
    Lukas B. Gromann
    Fabio De Marco
    Konstantin Willer
    Peter B. Noël
    Kai Scherer
    Bernhard Renger
    Bernhard Gleich
    Klaus Achterhold
    Alexander A. Fingerle
    Daniela Muenzel
    Sigrid Auweter
    Katharina Hellbach
    Maximilian Reiser
    Andrea Baehr
    Michaela Dmochewitz
    Tobias J. Schroeter
    Frieder J. Koch
    Pascal Meyer
    Danays Kunka
    Juergen Mohr
    Andre Yaroshenko
    Hanns-Ingo Maack
    Thomas Pralow
    Hendrik van der Heijden
    Roland Proksa
    Thomas Koehler
    Nataly Wieberneit
    Karsten Rindt
    Ernst J. Rummeny
    Franz Pfeiffer
    Julia Herzen
    Scientific Reports, 7
  • [7] A beam hardening and dispersion correction for x-ray dark-field radiography
    Pelzer, Georg
    Anton, Gisela
    Horn, Florian
    Rieger, Jens
    Ritter, Andre
    Wandner, Johannes
    Weber, Thomas
    Michel, Thilo
    MEDICAL PHYSICS, 2016, 43 (06) : 2774 - 2779
  • [8] Optimization of tube voltage in X-ray dark-field chest radiography
    Sauter, Andreas P.
    Andrejewski, Jana
    De Marco, Fabio
    Willer, Konstantin
    Gromann, Lukas B.
    Noichl, Wolfgang
    Kriner, Fabian
    Fischer, Florian
    Braun, Christian
    Koehler, Thomas
    Meurer, Felix
    Fingerle, Alexander A.
    Pfeiffer, Daniela
    Rummeny, Ernst
    Herzen, Julia
    Pfeiffer, Franz
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [9] Correction for X-Ray Scatter and Detector Crosstalk in Dark-Field Radiography
    Urban, Theresa
    Noichl, Wolfgang
    Engel, Klaus Juergen
    Koehler, Thomas
    Pfeiffer, Franz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (07) : 2646 - 2656
  • [10] Visualization of neonatal lung injury associated with mechanical ventilation using x-ray dark-field radiography
    Andre Yaroshenko
    Tina Pritzke
    Markus Koschlig
    Nona Kamgari
    Konstantin Willer
    Lukas Gromann
    Sigrid Auweter
    Katharina Hellbach
    Maximilian Reiser
    Oliver Eickelberg
    Franz Pfeiffer
    Anne Hilgendorff
    Scientific Reports, 6