The John Charnley Award Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip Arthroplasty A Randomized Clinical Trial

被引:236
|
作者
Garbuz, Donald S. [1 ]
Tanzer, Michael [2 ]
Greidanus, Nelson V. [1 ]
Masri, Bassam A. [1 ]
Duncan, Clive P. [1 ]
机构
[1] Univ British Columbia, Div Lower Limb Reconstruct & Oncol, Dept Orthopaed, Vancouver, BC V5Z 4E3, Canada
[2] McGill Univ, Dept Surg, Div Orthopaed Arthroplasty, Montreal, PQ H3A 2T5, Canada
关键词
FOLLOW-UP; FEMORAL-NECK; REPLACEMENT; COBALT; OSTEOARTHRITIS; VALIDATION; PROSTHESES; CHROMIUM; RELEASE; BLOOD;
D O I
10.1007/s11999-009-1029-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical trial to compare clinical outcomes of resurfacing versus large-head metal-on-metal total hip arthroplasty. We randomized 107 patients deemed eligible for resurfacing arthroplasty to have either resurfacing or standard THA. Patients were assessed for quality-of-life outcomes using the PAT-5D index, WOMAC, SF-36, and UCLA activity score. The minimum followup was 0.8 years (mean, 1.1 years; range, 0.8-2.2 years). Of the 73 patients followed at least one year, both groups reported improvement in quality of life on all outcome measures. There was no difference in quality of life between the two arms in the study. Serum levels of cobalt and chromium were measured in a subset of 30 patients. In both groups cobalt and chromium was elevated compared to baseline. Patients receiving a large-head metal-on-metal total hip had elevated ion levels compared to the resurfacing arm of the study. At 1 year, the median serum cobalt increased 46-fold from baseline in patients in the large-head total hip group, while the median serum chromium increased 10-fold. At 1 year, serum cobalt was 10-fold higher and serum chromium 2.6-fold higher than in the resurfacing arm. Due to these excessively high metal ion levels, the authors recommend against further use of this particular large-head total hip arthroplasty.
引用
收藏
页码:318 / 325
页数:8
相关论文
共 50 条
  • [41] Metal-on-metal articulation in total hip arthroplasty
    Marchetti, P.G.
    Binazzi, R.
    Vaccari, V.
    Manca, A.
    Rossi, R.
    Campagna, A.
    Magnani, M.
    Baldarelli, M.
    Pasini, E.
    1600, Trans Tech Publ, Uetikon-Zuerich, Switzerland (192-195): : 975 - 977
  • [42] Metal-on-metal articulation in total hip arthroplasty
    Marchetti, PG
    Binazzi, R
    Vaccari, V
    Manca, A
    Rossi, R
    Campagna, A
    Magnani, M
    Baldarelli, M
    Pasini, E
    BIOCERAMICS, 2000, 192-1 : 975 - 977
  • [43] Metal-on-metal hip resurfacing in osteonecrosis of the femoral head
    Revell, Matthew P.
    McBryde, Callum W.
    Bhatnagar, Sharad
    Pynsent, Paul B.
    Treacy, Ronan B. C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 98 - 103
  • [44] The rationale for metal-on-metal total hip arthroplasty
    Cuckler, JM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 132 - 136
  • [45] The Prevalence of Groin Pain After Metal-on-Metal Total Hip Arthroplasty and Total Hip Resurfacing
    Bartelt, Robert B.
    Yuan, Brandon J.
    Trousdale, Robert T.
    Sierra, Rafael J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2346 - 2356
  • [46] Painful metal-on-metal total hip arthroplasty
    Shahrdar, C
    Campbell, P
    Mirra, J
    Dorr, LD
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02): : 289 - 293
  • [47] The painful metal-on-metal hip resurfacing
    Hart, A. J.
    Sabah, S.
    Henckel, J.
    Lewis, A.
    Cobb, J.
    Sampson, B.
    Mitchell, A.
    Skinner, J. A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 738 - 744
  • [48] Controversies in large metal-on-metal cementless total hip arthroplasty
    Botez, P.
    Stoica, C. I.
    Sirbu, P. D.
    Asaftei, R.
    Grierosu, C.
    2010 ADVANCED TECHNOLOGIES FOR ENHANCING QUALITY OF LIFE (AT-EQUAL), 2010, : 40 - 43
  • [49] Modern Metal-on-metal Hip Resurfacing
    McGrory, Brian
    Barrack, Robert
    Lachiewicz, Paul F.
    Schmalzried, Thomas P.
    Yates, Adolph J., Jr.
    Watters, William C., III
    Turkelson, Charles M.
    Wies, Janet L.
    St Andre, Justin
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (05) : 306 - 314
  • [50] A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients—a minimum of five year follow-up
    Ran Tao
    Fan Liu
    Ya-ke Liu
    Yue Lu
    Hua Xu
    Yi Cao
    Zhen-yu Zhou
    Wei Wang
    International Orthopaedics, 2018, 42 : 2323 - 2327