Stem bending force and hydraulic system pressure sensing for predicting napiergrass yield during harvesting

被引:4
|
作者
Mathanker, S. K. [1 ]
Buss, J. C. [2 ]
Gan, H. [1 ]
Larsen, J. F. [3 ]
Hansen, A. C. [1 ,4 ]
机构
[1] Univ Illinois, Dept Agr & Biol Engn, Urbana, IL USA
[2] John Deere, Thibodawc, LA USA
[3] BP Biofuels North Amer, Houston, TX USA
[4] Univ KwaZulu Natal, Durban, South Africa
关键词
Napiergrass; Yield sensing; Yield maps; Harvesting; Bioenergy; Biomass; THROUGHPUT RATE; MISCANTHUS; GRASSES; SENSORS; BIOMASS; MASS;
D O I
10.1016/j.compag.2015.01.007
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Napiergrass, which resembles sugarcane in stature and cultivation practices, is emerging as a candidate bioenergy crop. However, limited studies investigating harvesting and yield sensing of napiergrass are available. This study investigated stem-bending force, and the hydraulic pressures of basecutter, chopper and elevator drives in a John Deere 3522 sugarcane billet harvester as indicators of napiergrass yield. The coefficients of determination (R-2) between napiergrass yield and hydraulic pressures were 0.73, 0.88 and 0.81, respectively for the basecutter, chopper and elevator drives. The highest correlation (R-2 = 0.92) was found between stem-bending force and napiergrass yield. The yield prediction errors were 4.9% and 8.6% for the calibration and validation plots with the stem-bending force yield sensor. Cross-validation, in which each harvested row was treated as a data point, showed that the average yield prediction errors were 10.9% and 11.8% for the calibration and validation data sets. Yield maps were also generated employing the stem-bending yield sensor. In addition, it was expected that the stem-bending yield sensor could be utilized to control harvester operation such as travel speed. Further studies would be needed to extend the stem-bending concept to other thick stemmed crops. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 50 条
  • [31] Towards the Evaluation of Force-Sensing Resistors for In Situ Measurement of Interface Pressure During Leg Compression Therapy
    Rahimi, Mahan
    Blaber, Andrew P.
    Menon, Carlo
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 25 - 28
  • [32] A Remote-Controlled Robotic System with Safety Protection Strategy Based on Force-Sensing and Bending Feedback for Transcatheter Arterial Chemoembolization
    Zhou, Junqiang
    Mei, Ziyang
    Miao, Jia
    Mao, Jingsong
    Wang, Lingyun
    Wu, Dezhi
    Sun, Daoheng
    Zhao, Yang
    MICROMACHINES, 2020, 11 (09)
  • [33] Measurement of peak pressure under the plantar surface of the foot in a standing position using a force sensing array system
    AlMijalli, MHS
    MEDICAL SCIENCE RESEARCH, 1997, 25 (03): : 215 - 216
  • [34] Effective excitation conditions for the intense motion of the ginkgo seed-stem system during mechanical vibration harvesting
    Zhou, Jie
    Xu, Linyun
    Zhao, Jiawei
    Hang, Xiaochen
    Zhou, Hongping
    BIOSYSTEMS ENGINEERING, 2022, 215 : 239 - 248
  • [35] Modeling and fuzzy PID control of the VVVF based pressure control system of man-made diamond hydraulic force machine
    Mo, Jinhai
    Wang, Hong
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 3610 - 3615
  • [36] Enabling Force Sensing During Ground Locomotion: A Bio-Inspired, Multi-Axis, Composite Force Sensor Using Discrete Pressure Mapping
    Chuah, Meng Yee
    Kim, Sangbae
    IEEE SENSORS JOURNAL, 2014, 14 (05) : 1693 - 1703
  • [37] Assessment System for Predicting Maximal Safe Range for Heel Height by Using Force-Sensing Resistor Sensors and Regression Models
    Hwang, Yi-Ting
    Lee, Si-Huei
    Lin, Bor-Shing
    SENSORS, 2022, 22 (09)
  • [38] MRI compatible force sensing system for real-time monitoring of wrist moments during fMRI testing
    Hidler, J
    Mbwana, J
    Zeffiro, T
    2005 IEEE 9TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, 2005, : 212 - 214
  • [39] MR compatible force sensing system for real-time monitoring of wrist moments during fMRI testing
    Hidler, Joseph
    Hodics, Timea
    Xu, Benjamin
    Dobkin, Bruce
    Cohen, Leonardo G.
    JOURNAL OF NEUROSCIENCE METHODS, 2006, 155 (02) : 300 - 307
  • [40] Integrated pressure-force-kinematics measuring system for the characterisation of plantar foot loading during locomotion
    C. Giacomozzi
    V. Macellari
    A. Leardini
    M. G. Benedetti
    Medical and Biological Engineering and Computing, 2000, 38 : 156 - 163