On the thermal buffering of naturally ventilated buildings through internal thermal mass

被引:42
|
作者
Holford, J. M. [1 ]
Woods, A. W. [1 ]
机构
[1] Univ Cambridge, BP Inst, Cambridge CB3 0EZ, England
关键词
D O I
10.1017/S0022112007005320
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In this paper we examine the role of thermal mass in buffering the interior temperature of a naturally ventilated building from the diurnal fluctuations in the environment. First, we show that the effective thermal mass which is in good thermal contact with the air is limited by the diffusion distance into the thermal mass over one diurnal temperature cycle. We also show that this effective thermal mass may be modelled as an isothermal mass. Temperature fluctuations in the effective thermal mass are attenuated and phase-shifted from those of the interior air, and therefore heat is exchanged with the interior air. The evolution of the interior air temperature is then controlled by the relative magnitudes of (i) the time for the heat exchange between the effective thermal mass and the air; (ii) the time for the natural ventilation to replace the air in the space with air from the environment; and (iii) the period of the diurnal oscillations of the environment. Through analysis and numerical solution of the governing equations, we characterize a number of different limiting cases. If the ventilation rate is very small, then the thermal mass buffers the interior air temperature from fluctuations in the environment, creating a near-isothermal interior. If the ventilation rate increases, so that there are many air changes over the course of a day, but if there is little heat exchange between the thermal mass and interior air, then the interior air temperature locks on to the environment temperature. If there is rapid thermal equilibration of the thermal mass and interior air, and a high ventilation rate, then both the thermal mass and the interior air temperatures lock on to the environment temperature. However, in many buildings, the more usual case is that in which the time for thermal equilibration is comparable to the period of diurnal fluctuations, and in which ventilation rates are moderate. In this case, the fluctuations of the temperature of the thermal mass lag those of the interior air, which in turn lag those of the environment. We consider the implications of these results for the use of thermal mass in naturally ventilated buildings.
引用
收藏
页码:3 / 29
页数:27
相关论文
共 50 条
  • [31] Investigating the adaptive model of thermal comfort for naturally ventilated school buildings in Taiwan
    Hwang, Ruey-Lung
    Lin, Tzu-Ping
    Chen, Chen-Peng
    Kuo, Nai-Jung
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2009, 53 (02) : 189 - 200
  • [32] Optimization of window-openings design for thermal comfort in naturally ventilated buildings
    Stavrakakis, G. M.
    Zervas, P. L.
    Sarimveis, H.
    Markatos, N. C.
    APPLIED MATHEMATICAL MODELLING, 2012, 36 (01) : 193 - 211
  • [33] Development of a metamodel to assess building thermal performance for naturally ventilated residential buildings
    Veiga, Rodolfo Kirch
    Eli, Leticia Gabriela
    Krelling, Amanda Fraga
    Olinger, Marcelo Salles
    Melo, Ana Paula
    Lamberts, Roberto
    PROCEEDINGS OF BUILDING SIMULATION 2021: 17TH CONFERENCE OF IBPSA, 2022, 17 : 1849 - 1856
  • [34] Thermal Perception in Naturally Ventilated University Buildings in Spain during the Cold Season
    Aguilar, Antonio J.
    de la Hoz-Torres, Maria L.
    Dolores Martinez-Aires, Maria
    Ruiz, Diego P.
    BUILDINGS, 2022, 12 (07)
  • [35] Thermal performance and comfort potential estimation in low-rise high thermal mass naturally ventilated office buildings in India: An experimental study
    Kumar, Sanjay
    Singh, Manoj Kumar
    Mathur, Anuj
    Mathur, Sanjay
    Mathur, Jyotirmay
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 569 - 584
  • [36] Towards a Brazilian standard for naturally ventilated buildings: guidelines for thermal and air movement acceptability
    Candido, Christhina
    Lamberts, Roberto
    de Dear, Richard
    Bittencourt, Leonardo
    de Vecchi, Renata
    BUILDING RESEARCH AND INFORMATION, 2011, 39 (02): : 145 - 153
  • [37] Thermal analysis of climate environments based on weather data in Singapore for naturally ventilated buildings
    Wang, LP
    Wong, NH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 234 - 238
  • [38] Thermal comfort analysis of PMV model Prediction in Air conditioned and Naturally Ventilated Buildings
    Gilani, Syed Ihtsham ul Haq
    Khan, Muhammad Hammad
    Pao, William
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1373 - 1379
  • [39] Assessment of Thermal Comfort in Naturally Ventilated Factory Buildings: A Case Study in Mumbai, India
    Sheth, Swarali
    Gupta, Apeksha
    Udyavar-Yehuda, Roshni
    SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 993 - 994
  • [40] Naturally ventilated and mixed-mode buildings-Part I: Thermal modeling
    Spindler, Henry C.
    Norford, Leslie K.