A carbon dioxide gas sensor based on solid electrolyte for air quality control

被引:55
|
作者
Kaneyasu, K
Otsuka, K
Setoguchi, Y
Sonoda, S
Nakahara, T
Aso, I
Nakagaichi, N
机构
[1] Figaro Engn, Osaka 5628505, Japan
[2] Yamatake Honeywell, Isehara Factory, Isehara, Kanagawa 2591195, Japan
关键词
gas sensor; solid electrolyte; carbon dioxide; air quality control;
D O I
10.1016/S0925-4005(99)00411-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A practical CO2 gas sensor for air quality control is developed by using a combination of a Na3Zr2Si2PO12 (NASICON) as a solid electrolyte and Li2CO3 as a carbonate phase. The sensor's electromotive force (emf) shows a linear relationship with the logarithm of CO2 concentration. Zeolite is chosen as a filter material in order to minimize the effect of interfering gases on the sensor's emf and shows very little sensor response deterioration to CO2. Under continuous energizing, both the emf and a change in the emf (defined as Delta emf) are stable over a period of 2 years. However, after the sensor is exposed to a high humidity atmosphere in an unpowered state, the emf decreases, but Delta emf stays constant. A new data selection method for renewing the standard of the emf is investigated in order to monitor CO2 concentration using Delta emf. The output of the CO2 monitor corresponds to a conventional non-dispersive infrared (NDIR) analyzer. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:56 / 58
页数:3
相关论文
共 50 条
  • [21] Solid state electrochemical gas sensor for the quantitative determination of carbon dioxide
    Schwandt, Carsten
    Kumar, R. Vasant
    Hills, Matthew P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 27 - 34
  • [22] Carbon dioxide gas sensor with multivalent cation conducting solid electrolytes
    Imanaka, N
    Kamikawa, M
    Tamura, S
    Adachi, G
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) : 301 - 306
  • [23] WATER-VAPOR INFLUENCE ON CARBON-DIOXIDE DETECTION OF THE SENSOR BASED ON LITHIUM CONDUCTING SOLID ELECTROLYTE
    IMANAKA, N
    KAWASATO, T
    ADACHI, G
    CHEMISTRY LETTERS, 1991, (10) : 1743 - 1746
  • [24] CARBON DIOXIDE AND AIR QUALITY
    HELMS, JA
    JOURNAL OF FORESTRY, 1971, 69 (03) : 169 - &
  • [25] Electrode kinetic study of silver-ion doping effect in solid-electrolyte potentiometric carbon dioxide gas sensor
    Dubbe, A
    Wiemhofer, HD
    Sadaoka, Y
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (03) : 943 - 947
  • [26] THE AIR QUALITY EVALUATION BASED ON GAS SENSOR ARRAY
    Chiu, Chang-yong
    Zhang, Zhun
    2017 CHINA SEMICONDUCTOR TECHNOLOGY INTERNATIONAL CONFERENCE (CSTIC 2017), 2017,
  • [27] AN AMPEROMETRIC SOLID-STATE SENSOR FOR NITROGEN-DIOXIDE BASED ON A SOLID POLYMER ELECTROLYTE
    OPEKAR, F
    ELECTROANALYSIS, 1992, 4 (02) : 133 - 138
  • [28] Novel carbon dioxide gas sensor based on infrared absorption
    Zhang, GJ
    Lui, JF
    Yuan, M
    OPTICAL ENGINEERING, 2000, 39 (08) : 2235 - 2240
  • [29] New type of sulfur dioxide gas sensor based on trivalent Al3+ ion conducting solid electrolyte
    Inaba, Yuichi
    Tamura, Shinji
    Imanaka, Nobuhito
    SOLID STATE IONICS, 2008, 179 (27-32) : 1625 - 1627
  • [30] Control of Electrode Reactions in a Mixed-Potential-Type Gas Sensor Based on a BiCuVOx Solid Electrolyte
    Kida, Tetsuya
    Harano, Hiroaki
    Minami, Takuya
    Kishi, Shotaro
    Morinaga, Naoki
    Yamazoe, Noboru
    Shimanoe, Kengo
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (35): : 15141 - 15148