Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma

被引:58
|
作者
Rigo-Bonnin, Raul [1 ]
Ribera, Alba [2 ,3 ]
Arbiol-Roca, Ariadna [1 ]
Cabo-Sacristan, Sara [4 ]
Padulles, Ariadna [4 ]
Murillo, Oscar [2 ,3 ]
Shaw, Evelyn [2 ,3 ]
Granada, Rosa [5 ]
Perez-Fernandez, Xose L. [5 ]
Tubau, Fe [6 ,7 ]
Alia, Pedro [1 ]
机构
[1] Hosp Univ Bellvitge, IDIBELL, Lab Clin Dept, Barcelona, Spain
[2] Hosp Univ Bellvitge, IDIBELL, Infect Dis Dept, Barcelona, Spain
[3] Inst Salud Carlos III, Spanish Network Res Infect Dis REIPI RD12 0012, Madrid, Spain
[4] Hosp Univ Bellvitge, IDIBELL, Pharm Dept, Barcelona, Spain
[5] Hosp Univ Bellvitge, IDIBELL, Intens Care Dept, Barcelona, Spain
[6] Hosp Univ Bellvitge, IDIBELL, Microbiol Dept, Barcelona, Spain
[7] Inst Salud Carlos III, Spanish Network Biomed Res Resp Dis CIBERES CB06, Madrid, Spain
关键词
beta-Lactam antibiotics; Human plasma; Protein precipitation; UHPLC-MS/MS; Therapeutic drug monitoring; HUMAN SERUM; UPLC; QUANTIFICATION; CEPHALOSPORINS; PIPERACILLIN; INFUSION; SOCIETY; HPLC;
D O I
10.1016/j.cca.2017.03.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The administration of beta-lactam antibiotics in continuous infusion could let optimize the pharmacokinetic/pharmacodynamic parameters, especially in the treatment of serious bacterial infections. In this context, and also due to variability in their plasmatic concentrations, therapeutic drug monitoring (TDM) may be useful to optimize dosing and, therefore, be useful for the clinicians. Material and methods: We developed and validated a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of amoxicillin, ampicillin, cloxacillin, piperacillin, cefepime, ceftazidime, cefuroxime, aztreonam and meropenem concentrations in plasma. The chromatographic separation was achieved using an Acquity (R)-UPLC (R) BEH (TM) (2.1 x 100 mm id, 1.7 pm) reverse-phase C-18 column, with a water/acetonitrile linear gradient containing 0.1% formic acid at a 0.4 mL/min flow rate. beta-Lactam antibiotics and their internal standards were detected by electrospray ionization mass spectrometry in multiple reaction monitoring mode. Results: Chromatography run time was 7.0 min and beta-lactam antibiotics eluted at retention times ranging between 1.08 and 1.91 min. The lower limits of quantification were between 0.50 and 1.00 mg/L. Coefficients of variation and relative bias absolute values were <13.3% and 14.7%, respectively. Recovery values ranged from 55.7% to 84.8%. Evaluation of the matrix effect showed ion enhancement for all antibiotics. No interferences or carryover were observed. Conclusions: Our measurement procedure could be applied to daily clinical laboratory practice to measure the concentration of beta lactam antibiotics in plasma, for instance in patients with bone and joint infections and critically ill patients. 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [21] Determination of Oxycodone in Rat Plasma by a Simple Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Liu, Fuli
    Ye, Luxin
    Dong, Yanwen
    Wang, Qianqian
    Cai, Fuman
    LATIN AMERICAN JOURNAL OF PHARMACY, 2018, 37 (03): : 611 - 615
  • [22] Determination of mitomycin C in rabbit plasma by ultra-high performance liquid chromatography-tandem mass spectrometry
    Tang Yao
    Zhang Shuangqing
    Li Xiang
    Sun Xu
    Wen Nie
    Yu Min
    Peng Lili
    Li Jinrang
    Li Zuogang
    Li Bo
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) : 154 - 159
  • [23] Determination of methocarbamol concentration in human plasma by high performance liquid chromatography-tandem mass spectrometry
    Zha, Wuyi
    Zhu, Zhimeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (9-10): : 831 - 835
  • [24] Measurement of urinary oxypurinol by high performance liquid chromatography-tandem mass spectrometry
    Stocker, Sophie L.
    Franklin, Michael E.
    Anderson, Jacqueline M.
    Pillans, Peter I.
    Williams, Kenneth M.
    McLachlan, Andrew J.
    Day, Richard O.
    Taylor, Paul J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (25): : 2363 - 2368
  • [25] Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for quantifying lenacapavir plasma concentrations: Application to therapeutic monitoring
    West III, Raymond E.
    Oberly, Patrick J.
    Riddler, Sharon A.
    Nolin, Thomas D.
    Devanathan, Aaron S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1230
  • [26] DETERMINATION OF GINGEROLS IN GINGER BY ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ashraf, Kamran
    Mujeeb, Mohd
    Ahmad, Altaf
    Ahmad, Sayeed
    Ahmad, Niyaz
    Amir, Mohd
    ANALYTICAL LETTERS, 2014, 47 (12) : 2120 - 2128
  • [27] Simultaneous Determination of 112 Synthetic Cannabinoids in Hair by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Huang Y.
    Zhang T.-T.
    Hu S.
    Jia W.
    Wang Y.-M.
    Su M.-X.
    Hua Z.-D.
    Journal of Chinese Mass Spectrometry Society, 2022, 43 (04) : 426 - 437
  • [28] Simultaneous determination of 58 glucocorticoid residues in milk by ultra-high performance liquid chromatography-tandem mass spectrometry
    Guo, Can
    Wu, Cuiling
    Zhang, Zihao
    Tan, Sijia
    Chen, Sumeng
    Chen, Gang
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1719
  • [29] Fast and simultaneous determination of endocrine disrupting compounds by ultra-high performance liquid chromatography-tandem mass spectrometry
    Esteve, C.
    Herrero, L.
    Gomara, B.
    Quintanilla-Lopez, J. E.
    TALANTA, 2016, 146 : 326 - 334
  • [30] A multiresidue approach for the simultaneous quantification of antibiotics in macroalgae by ultra-high performance liquid chromatography-tandem mass spectrometry
    Leston, Sara
    Freitas, Andreia
    Rosa, Joao
    Barbosa, Jorge
    Lemos, Marco F. L.
    Pardal, Miguel Angelo
    Ramos, Fernando
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 361 - 367