Skills evaluation in minimally invasive surgery using force/torque signatures

被引:108
|
作者
Richards, C
Rosen, J
Hannaford, B
Pellegrini, C
Sinanan, M
机构
[1] Univ Washington, Dept Surg, Seattle, WA 98195 USA
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
关键词
laparoscopy; training; technical skills; force-torque signatures; haptics; surgical simulators; minimally invasive surgery;
D O I
10.1007/s004640000230
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: One of the more difficult tasks in surgical education is to teach the optimal application of instrument forces and torques necessary to facilitate the conduct of an operation. For laparoscopic surgery, this type of training has traditionally taken place in the operating room, reducing operating room efficiency and potentially affecting the safe conduct of the operation. The objective of the current study was to measure and compare forces and torques (F/T) applied at the tool/hand interface generated during laparoscopic surgery by novice (NS) and experienced (ES) surgeons using an instrumented laparoscopic grasper and to use this data for evaluating the skill level. Methods: Ten surgeons (five-NS, five-ES) performed a cholecystectomy and Nissen fundoplication in a porcine model. An instrumented laparoscopic grasper with interchangeable standard surgical tips equipped with a three-axis F/T sensor located at the proximal end of the grasper tube was used to measure the F/T at the hand/tool interface. In addition, one axis force sensor located at the grasper's handle was used to measure the grasping force. F/T data synchronized with visual view of the tool operative maneuvers were collected simultaneously via a novel graphic user interface incorporated picture-in-picture video technology. Subsequent frame-by-frame video analysis of the operation allowed a definition of states associated with different tool/tissue interactions within each step of the operation. F/T measured within each state were further analyzed using vector quantization (VQ). The VQ analysis defines characteristic sets of F/T in the database that were defined as F/T signature. Results: The magnitude of F/T applied by NS and ES were significantly different (p < 0.05) and varied based on the task being performed. Higher F/T magnitudes were applied by NS than by ES when performing tissue manipulation, whereas lower F/T magnitudes were applied by NS than by ES during tissue dissection. Furthermore, the time to complete the surgical procedure was longer for NS by a factor of 1.5-4.8 when compared to the time for ES. State analysis suggests that most of this time is consumed in an [idle] state, in which movements of the surgeon make no tissue contact. Conclusions: Preliminary data suggest that F/T magnitudes associated with the tool/tissue interactions provide an objective means of distinguishing novices from skilled surgeons. Clinical F/T analysis using the proposed technology and methodology may be helpful in training, developing surgical simulators, and measuring technical proficiency during laparoscopic surgery.
引用
收藏
页码:791 / 798
页数:8
相关论文
共 50 条
  • [21] New Training Options for Minimally Invasive Surgery Skills
    Fransson, Boel A.
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2024, 54 (04) : 603 - 613
  • [22] Task decomposition of minimally invasive surgery for objective evaluation of laparoscopic surgical skills using hidden Markov model
    Rosen, Jacob
    Solazzo, Massimiliano
    Hannaford, Blake
    Sinanan, Mika
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [23] Temperature Independent Triaxial Force and Torque Sensor for Minimally Invasive Interventions
    Taghipour, Ata
    Cheema, Asim N.
    Gu, Xijia
    Janabi-Sharifi, Farrokh
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2020, 25 (01) : 449 - 459
  • [24] A Robust Uniaxial Force Sensor for Minimally Invasive Surgery
    Yip, Michael C.
    Yuen, Shelten G.
    Howe, Robert D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (05) : 1008 - 1011
  • [25] Force controlled and teleoperated endoscopic grasper for minimally invasive surgery - Experimental performance evaluation
    Rosen, J
    Hannaford, B
    MacFarlane, MP
    Sinanan, MN
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (10) : 1212 - 1221
  • [26] Optical Force Sensing In Minimally Invasive Robotic Surgery
    Hosseinabadi, Amir Hossein Hadi
    Honarvar, Mohammad
    Salcudean, Septimiu E.
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2019, : CP1 - CP46
  • [27] Modeling and Simulation of Graspers Force in Minimally Invasive Surgery
    Hortamani, Ramin
    Zabihollah, Abolghassem
    IACSIT-SC 2009: INTERNATIONAL ASSOCIATION OF COMPUTER SCIENCE AND INFORMATION TECHNOLOGY - SPRING CONFERENCE, 2009, : 475 - 479
  • [28] Minimally invasive surgical skills evaluation in the field of otolaryngology
    Cuevas, Alejandro
    Lorias, Daniel
    Minor, Arturo
    Gutierrez, Jose A.
    Martinez, Rigoberto
    2013 IEEE 26TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2013, : 83 - 88
  • [29] A Sensorized Instrument for Skills Assessment and Training in Minimally Invasive Surgery
    Trejos, A. L.
    Patel, R. V.
    Naish, M. D.
    Lyle, A. C.
    Schlachta, C. M.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2009, 3 (04):
  • [30] Effects of experience on force perception threshold in minimally invasive surgery
    Zhou, M.
    Perreault, J.
    Schwaitzberg, S. D.
    Cao, C. G. L.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (02): : 510 - 515