Validity and Responsiveness to Change of the 30-Second Chair-Stand Test in Older Adults Admitted to an Emergency Department

被引:22
|
作者
Bruun, Inge Hansen [1 ,2 ]
Mogensen, Christian B. [2 ,3 ]
Norgaard, Birgitte [4 ]
Schiottz-Christensen, Berit [2 ,5 ]
Maribo, Thomas [6 ,7 ]
机构
[1] Lillebaelt Hosp, Dept Physiotherapy & Occupat Therapy, Sygehusvej 24, DK-6000 Kolding, Denmark
[2] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
[3] Hosp Southern Jutland, Emergency Dept, Aabenraa, Denmark
[4] Univ Southern Denmark, Dept Publ Hlth, Odense, Denmark
[5] Lillebaelt Hosp, Spine Ctr Southern Denmark, Middelfart, Denmark
[6] Aarhus Univ, Dept Publ Hlth, Aarhus, Denmark
[7] Cent Denmark Reg, DEFACTUM, Aarhus, Denmark
关键词
acutely admitted older adults; physical performance; responsiveness to change; 30-second Chair-Stand Test; validity; MORTON MOBILITY INDEX; ACUTE-CARE; PERFORMANCE; COMMUNITY; RELIABILITY; DEMMI;
D O I
10.1519/JPT.0000000000000166
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background and Purpose: Few physical performance measurement tools are validated for acutely admitted older adults, and for this reason we aimed to examine the validity and responsiveness to change of the 30-second Chair-Stand Test (30s-CST) used to assess physical performance in older adults admitted to a short-stay unit in an emergency department. Methods: Construct validity of the 30s-CST, using 8 as a cutoff point for dependency in activities of daily living, was examined using 207 patients. Self-reported information on everyday activities was obtained by asking patients about need for help in bathing, dressing, cooking, cleaning, and shopping. Concurrent validity of the 30s-CST compared with the de Morton Mobility Index (DEMMI) on physical performance of acutely admitted older adults was examined with 156 patients. The analysis of concurrent validity included the entire DEMMI and 2 subsets of DEMMI: "DEMMI walking" and "DEMMI dynamic balance." The responsiveness to change in the 30s-CST compared with DEMMI was examined with 117 patients. All patients were classified as having either low physical performance (30s-CST <= 8) or high physical performance (30sCST >8); these groups were used in the analysis of validity and responsiveness to change. Results and Discussion: Regarding construct validity using 8 as a cutoff point, the study showed a significant difference between patients with low physical performance compared with patients with high physical performance. Moreover, a decrease in the 30s-CST was followed by an increase in the need for help with everyday activities. There was a significant association between the 30s-CST and DEMMI (r = 0.72); for every extra repetition in the 30s-CST, the DEMMI score increased by 4.9. There was a significant association between the 30s-CST and the 2 subsets "DEMMI walking" and "DEMMI dynamic balance"; yet, a pronounced floor effect was found in the subsets. The analysis demonstrated a very wide prediction interval, indicating that DEMMI has a better responsiveness to change than the 30s-CST, especially in older adults with low physical performance. However, the 30s-CST is easier and faster to use than DEMMI. Conclusion: This study found a significant difference in the patients' need for help with everyday activities when comparing low and high physical performance groups. The concurrent validity of the 30s-CST was acceptable in assessing physical performance in older adults at the time of admission; the 30s-CST is thus a tool that is easy to use in older adults with acute disease. In contrast, based on very wide prediction intervals, DEMMI demonstrated better responsiveness to change than the 30sCST, especially in older adults with low physical performance.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 43 条
  • [21] Relationship between sit-to-stand movements and physical function in healthy older adults: Testing duration power and displacement velocities for A 30-second chair-rise test
    Mahato, Niladri Kumar
    Davis, Alexandria
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2025, 42 : 139 - 145
  • [22] Automatic and Real-Time Computation of the 30-Seconds Chair-Stand Test without Professional Supervision for Community-Dwelling Older Adults
    Cobo, Antonio
    Villalba-Mora, Elena
    Perez-Rodriguez, Rodrigo
    Ferre, Xavier
    Escalante, Walter
    Moral, Cristian
    Rodriguez-Manas, Leocadio
    SENSORS, 2020, 20 (20) : 1 - 24
  • [23] Temporal Patterns in Performance of the 30 s Chair-Stand Test Evince Differences in Physical and Mental Characteristics among Community-Dwelling Older Adults in Japan
    Goda, Akio
    Murata, Shin
    Nakano, Hideki
    Matsuda, Hina
    Yokoe, Kana
    Mitsumoto, Hodaka
    Shiraiwa, Kayoko
    Abiko, Teppei
    Horie, Jun
    HEALTHCARE, 2020, 8 (02)
  • [24] The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Fox, Samantha
    Solomon, Andrew J.
    McGinnis, Ryan S.
    IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2022, 30 : 1213 - 1222
  • [25] The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy
    Aktar, Burcin
    Balci, Birgul
    Oztura, Ibrahim
    Baklan, Baris
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024, 40 (10)
  • [26] The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Fox, Samantha
    Solomon, Andrew J.
    Mcginnis, Ryan S.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 1213 - 1222
  • [27] Test-retest reliability and validity of the timed up and go test and 30-second sit to stand test in patients with pulmonary hypertension
    Kahraman, Buse Ozcan
    Ozsoy, Ismail
    Akdeniz, Bahri
    Ozpelit, Ebru
    Sevinc, Can
    Acar, Serap
    Savci, Sema
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 304 : 159 - 163
  • [28] Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Allen, Dakota
    Solomon, Andrew J.
    McGinnis, Ryan S.
    GAIT & POSTURE, 2022, 94 : 19 - 25
  • [29] THE USEFULNESS OF A 30-SECOND CHAIR STAND TEST FOR EVALUATING EXERCISE CAPACITY IN PATIENTS WITH MILD-TO-MODERATE INTERSTITIAL LUNG DISEASE
    Ishihara, Atsushi
    Taga, Shu
    Nakatake, Hitoshi
    Nakamura, Satsuki
    Miyahara, Toshihiro
    Kou, Takashi
    Itoh, Shinichi
    Nishiyama, Osamu
    RESPIROLOGY, 2013, 18 : 136 - 136
  • [30] Test-retest reliability of the 50-foot timed walk and 30-second chair stand test in patients with total hip arthroplasty
    Unver, Bayram
    Kahraman, Turhan
    Kalkan, Serpil
    Yuksel, Ertugrul
    Karatosun, Vasfi
    Gunal, Izge