Control of Legionella pneumophila contamination in a respiratory hydrotherapy system with sulfurous spa water

被引:17
|
作者
Leoni, E. [1 ]
Sacchetti, R. [1 ]
Zanetti, F. [1 ]
Legnani, P. P. [1 ]
机构
[1] Univ Bologna, Dept Publ & Hlth Med, Div Hyg, I-40126 Bologna, Italy
来源
关键词
D O I
10.1086/504364
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE. To evaluate the effectiveness of different disinfection treatments in a spa water system contaminated by Legionella pneumophila and associated with a case of Legionella pneumonia. DESIGN. During an 18-month period, the spa water was analyzed by taking samples from the well, the recirculation line, and the final distribution devices ( nebulizers and nasal irrigators). Various attempts were made to eradicate Legionella organisms by chemical and thermal shock. The final protocol consisted of heat shock treatment at 70 degrees C- 75 degrees C for 3 hours, 2 nights per week, followed by a lowering of the water temperature to 30 degrees C +/- 1 degrees C for use in the plant. In addition, 3 times a week superheated steam ( at a pressure of 1 atmosphere) was introduced for 1 hour into the nebulization machines. SETTING. A spa at which sulfurous water was used for hydrotherapy by means of aerosol and nasal irrigation. PATIENT. A 74-year-old woman with legionnaires disease. RESULTS. After the case of infection occurred, L. pneumophila was isolated from the recirculation line at a concentration of 400,000 cfu/ L and from the nebulizers and nasal irrigators at levels ranging from 3,300 to 1,800,000 cfu/ L. The colonizing organisms consisted of a mixture of L. pneumophila serogroup 1 ( 12%) and serogroup 5 ( 88%). The shock treatment with chlorine dioxide and peracetic acid resulted in the eradication of Legionella organisms from the recirculation line but not from the water generated from the final distribution devices. After the restructuring of the plant and the application of thermal shock protocol, an evaluation after 12 months revealed no evidence of Legionella contamination. CONCLUSION. To prevent Legionella colonization, disinfection treatment is effective if associated with carefully selected materials, good circuit design, and good maintenance practices.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 50 条
  • [21] Contamination of the cold water distribution system of health care facilities by Legionella pneumophila: Do we know the true dimension?
    Arvand, M.
    Jungkind, K.
    Hack, A.
    EUROSURVEILLANCE, 2011, 16 (16) : 9 - 14
  • [22] Confirming the Presence of Legionella pneumophila in Your Water System: A Review of Current Legionella Testing Methods
    Walker, James T.
    McDermott, Paul J.
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (04) : 1135 - 1147
  • [23] Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system
    Lagana, Pasqualina
    Moscato, Umberto
    Poscia, Andrea
    La Milia, Daniele Ignazio
    Boccia, Stefania
    Avventuroso, Emanuela
    Delia, Santi
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2015, 22 (04) : 655 - 660
  • [24] Hot water plumbing in residences and office buildings have distinctive risk of Legionella pneumophila contamination
    Donohue, Maura J.
    Mistry, Jatin H.
    Tucker, Nicole
    Vesper, Stephen J.
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2022, 245
  • [25] MICROBIAL-CONTAMINATION OF WATER BY MATERIALS OF PIPES AND HOSES .2. GROWTH OF LEGIONELLA PNEUMOPHILA
    SCHOENEN, D
    SCHULZEROBBECKE, R
    SCHIRDEWAHN, N
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1988, 186 (04): : 326 - 332
  • [26] CONTAMINATION OF DOMESTIC WATER-HEATERS WITH LEGIONELLA-PNEUMOPHILA - IMPACT OF WATER TEMPERATURE ON GROWTH AND DISSEMINATION OF THE BACTERIUM
    DEWAILLY, E
    JOLY, JR
    ENVIRONMENTAL TOXICOLOGY AND WATER QUALITY, 1991, 6 (02): : 249 - 257
  • [27] Legionella pneumophila and Protozoan Hosts: Implications for the Control of Hospital and Potable Water Systems
    Nisar, Muhammad Atif
    Ross, Kirstin E.
    Brown, Melissa H.
    Bentham, Richard
    Whiley, Harriet
    PATHOGENS, 2020, 9 (04):
  • [28] Effect of heat shock on hot water plumbing microbiota and Legionella pneumophila control
    Ji, Pan
    Rhoads, William J.
    Edwards, Marc A.
    Pruden, Amy
    MICROBIOME, 2018, 6
  • [29] Effect of heat shock on hot water plumbing microbiota and Legionella pneumophila control
    Pan Ji
    William J. Rhoads
    Marc A. Edwards
    Amy Pruden
    Microbiome, 6
  • [30] COLONIZATION OF COMPONENTS OF A MODEL HOT WATER-SYSTEM BY LEGIONELLA-PNEUMOPHILA
    SCHOFIELD, GM
    LOCCI, R
    JOURNAL OF APPLIED BACTERIOLOGY, 1985, 58 (02): : 151 - 162