Control of Legionella pneumophila contamination in a respiratory hydrotherapy system with sulfurous spa water

被引:17
|
作者
Leoni, E. [1 ]
Sacchetti, R. [1 ]
Zanetti, F. [1 ]
Legnani, P. P. [1 ]
机构
[1] Univ Bologna, Dept Publ & Hlth Med, Div Hyg, I-40126 Bologna, Italy
来源
关键词
D O I
10.1086/504364
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE. To evaluate the effectiveness of different disinfection treatments in a spa water system contaminated by Legionella pneumophila and associated with a case of Legionella pneumonia. DESIGN. During an 18-month period, the spa water was analyzed by taking samples from the well, the recirculation line, and the final distribution devices ( nebulizers and nasal irrigators). Various attempts were made to eradicate Legionella organisms by chemical and thermal shock. The final protocol consisted of heat shock treatment at 70 degrees C- 75 degrees C for 3 hours, 2 nights per week, followed by a lowering of the water temperature to 30 degrees C +/- 1 degrees C for use in the plant. In addition, 3 times a week superheated steam ( at a pressure of 1 atmosphere) was introduced for 1 hour into the nebulization machines. SETTING. A spa at which sulfurous water was used for hydrotherapy by means of aerosol and nasal irrigation. PATIENT. A 74-year-old woman with legionnaires disease. RESULTS. After the case of infection occurred, L. pneumophila was isolated from the recirculation line at a concentration of 400,000 cfu/ L and from the nebulizers and nasal irrigators at levels ranging from 3,300 to 1,800,000 cfu/ L. The colonizing organisms consisted of a mixture of L. pneumophila serogroup 1 ( 12%) and serogroup 5 ( 88%). The shock treatment with chlorine dioxide and peracetic acid resulted in the eradication of Legionella organisms from the recirculation line but not from the water generated from the final distribution devices. After the restructuring of the plant and the application of thermal shock protocol, an evaluation after 12 months revealed no evidence of Legionella contamination. CONCLUSION. To prevent Legionella colonization, disinfection treatment is effective if associated with carefully selected materials, good circuit design, and good maintenance practices.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 50 条
  • [1] Legionella anisa, a possible indicator of water contamination by Legionella pneumophila
    van der Mee-Marquet, N
    Domelier, AS
    Arnault, L
    Bloc, D
    Laudat, P
    Hartemann, P
    Quentin, R
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (01) : 56 - 59
  • [2] Control of Legionella pneumophila in a hospital water system by chlorine dioxide
    Walker, J. T.
    Mackerness, C. W.
    Mallon, D.
    Makin, T.
    Journal of Industrial Microbiology,
  • [3] THE CONTAMINATION OF HOSPITAL WATER SUPPLY SYSTEMS BY LEGIONELLA PNEUMOPHILA
    Tartakovsky, I. S.
    Gruzdeva, O. A.
    Sharapchenko, S. O.
    Gabrielyan, N., I
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2021, 23 (01): : 125 - 130
  • [4] CONTROL OF LEGIONELLA PNEUMOPHILA IN A HOSPITAL HOT WATER-SYSTEM
    SCHULZEROBBECKE, R
    JUNG, KD
    PULLMANN, H
    HUNDGEBURTH, J
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1990, 190 (1-2): : 84 - 100
  • [5] Predictive Factors of Legionella pneumophila Contamination in Cooling Tower Water
    Luksamijarulkul, Pipat
    Kornkrerkkiat, Sumawadee
    Saranpuetti, Chayaporn
    Sujirarat, Dusit
    AIR SOIL AND WATER RESEARCH, 2014, 7 : 11 - 17
  • [6] Persistent contamination of a hospital hot water network by Legionella pneumophila
    Jeanvoine, Audrey
    Richard, Marion
    Meunier, Alexandre
    Chassagne, Sophie
    Cholley, Pascal
    Gbaguidi-Haore, Houssein
    Sauget, Marlene
    Bertrand, Xavier
    Hocquet, Didier
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2023, 250
  • [7] Characterization of Legionella pneumophila Isolated from Environmental Water and Ashiyu Foot Spa
    Tachibana, Masato
    Nakamoto, Masaya
    Kimura, Yui
    Shimizu, Takashi
    Watarai, Masahisa
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [8] Contamination of a Dental Unit Water Line System by Legionella Pneumophila in the Mashhad School of Dentistry in 2009
    Ajami, B.
    Ghazvini, K.
    Movahhed, T.
    Ariaee, N.
    Shakeri, M. T.
    Makarem, S.
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2012, 14 (06) : 376 - 378
  • [9] Control of Legionella contamination in a hospital water distribution system by monochloramine
    Marchesi, Isabella
    Cencetti, Stefano
    Marchegiano, Patrizia
    Frezza, Giuseppina
    Borella, Paola
    Bargellini, Annalisa
    AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (03) : 279 - 281
  • [10] A meta-analysis of Legionella pneumophila contamination in hospital water systems
    Fang, Zisi
    Zhou, Xiaocong
    Liao, Hui
    Xu, Hong
    AMERICAN JOURNAL OF INFECTION CONTROL, 2023, 51 (11) : 1250 - 1262