Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes

被引:86
|
作者
Abitbol, Olivia [1 ,2 ,3 ]
Bouden, Jihene [2 ,3 ]
Doan, Serge [2 ,3 ]
Hoang-Xuan, Thanh [2 ,3 ]
Gatinel, Damien [2 ,3 ]
机构
[1] St Joseph Fdn, Glaucoma Inst, Dept Ophthalmol, F-75674 Paris 14, France
[2] Hop Bichat Claude Bernard, Dept Ophthalmol, F-75877 Paris 18, France
[3] Rothschild Fdn, Dept Ophthalmol, Paris, France
关键词
central corneal thickness; corneal biomechanics; glaucoma; hysteresis; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; ACQUIRED PIT; OPTIC-NERVE; RISK-FACTOR; THICKNESS; HYPERTENSION; DAMAGE;
D O I
10.1111/j.1755-3768.2009.01554.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify differences in corneal hysteresis (CH) and central corneal thickness (CCT) between healthy and glaucomatous patients. Methods: Retrospective observational study. One hundred and thirty-three eyes of 75 healthy and 58 glaucomatous patients were included. CH was measured in each patient using Ocular Response Analyzer. CCT was determined by ultrasonic pachymetry. For each patient, one eye was randomly selected. We used a Student t-test to search for significant differences between the different groups (p < 0.05). Results: In healthy and glaucomatous eyes, mean CH values were 10.46 +/- 1.6 and 8.77 +/- 1.4 mm Hg, respectively. Mean CCT values were 560.2 +/- 36.3 and 535.3 +/- 42.7 mu m, respectively. CH and CCT were significantly lower in glaucomatous eyes than in normal eyes, (p < 0.05). Discussion: In our series, CH was lower in glaucomatous than in normal eyes. The relationship between glaucoma, IOP, and ocular structures may not be confined to the consideration of CCT. A low CH value could be responsible for under-estimation of IOP. CH could also be a risk factor for glaucoma, independent of IOP. Further studies are needed to support these hypotheses. Conclusion: In our investigation, CCT and CH were significantly lower in glaucomatous eyes than in healthy eyes.
引用
收藏
页码:116 / 119
页数:4
相关论文
共 50 条
  • [21] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Emine Sen
    Yasemin Tutuncu
    Melike Balikoglu-Yilmaz
    Ufuk Elgin
    Dilek Berker
    Faruk Ozturk
    Serdar Guler
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1283 - 1288
  • [22] Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the Reichert Ocular Response Analyzer
    Kirwan, Caitriona
    O'Malley, Donal
    O'Keefe, Michael
    OPHTHALMOLOGICA, 2008, 222 (05) : 334 - 337
  • [23] DIURNAL VARIATIONS OF OCULAR PRESSURE IN NORMAL + IN GLAUCOMATOUS EYES
    DAVANGER, M
    ACTA OPHTHALMOLOGICA, 1964, 42 (04): : 764 - &
  • [24] Factors Affecting Corneal Biomechanics Measured With the Ocular Response Analyzer - Interim Analysis
    Kotecha, A.
    Sinapis, D.
    Sinapis, A.
    Garway-Heath, D. F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [25] Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer
    Ayala, Marcelo
    Chen, Enping
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1803 - 1806
  • [26] Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer
    Marcelo Ayala
    Enping Chen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1803 - 1806
  • [27] Corneal hysteresis and intraocular pressure measurement in children using the Reichert Ocular Response Analyzer
    Kirwan, Caitriona
    O'Keefe, Michael
    Lanigan, Bernadette
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 990 - 992
  • [28] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [29] Factors affecting corneal hysteresis in normal eyes
    Kazutaka Kamiya
    Mana Hagishima
    Fusako Fujimura
    Kimiya Shimizu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246
  • [30] Factors affecting corneal hysteresis in normal eyes
    Kamiya, Kazutaka
    Hagishima, Mana
    Fujimura, Fusako
    Shimizu, Kimiya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (10) : 1491 - 1494