Comparison of cardiac stroke volume measurement determined using stereological analysis of breath-hold cine MRI and phase contrast velocity mapping

被引:16
|
作者
Graves, MJ [1 ]
Dommett, DMF [1 ]
机构
[1] St George Hosp, Dept Radiol, Magnet Resonance Unit, London SW17 0QT, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2000年 / 73卷 / 872期
关键词
D O I
10.1259/bjr.73.872.11026856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cine MRI of the heart using segmented ii-space pulse sequences permits multiphase images to be acquired in a single breath-hold. Whilst image quality is improved compared with conventional (non-segmented) cine imaging, subsequent analysis can be relatively time consuming. In this study, multiple slice breath-hold cine imaging of the heart was performed in 11 normal volunteers. Left and right ventricular stroke volume (SV) was estimated from the images by application of the Cavalieri method of modern design stereology in combination with point counting. The measured SVs were compared with those obtained by cine phase contrast velocity mapping in the ascending aorta and main pulmonary artery. Excellent agreement was found between the SVs determined by the two techniques, with mean differences (+/- one SD) of 0.41 +/- 3.00 ml and 0.41 +/- 4.78 ml for left and right ventricles, respectively. Comparison of left and right ventricular SV using stereology yielded a mean difference of 0.84 +/- 5.70 ml. Breath-hold data acquisition together with stereological analysis is demonstrated to be an accurate and unbiased technique for the rapid assessment of cardiac function.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 41 条
  • [21] Peak velocity estimation in aortic stenosis patients using a fast three-directional two-dimensional phase contrast technique in a single breath-hold: comparison to unidirectional phase contrast MRI and transthoracic echocardiography
    Juliana Serafim da Silveira
    Matthew E Smyke
    Rizwan Ahmad
    Ning Jin
    Debbie Scandling
    Jennifer A Dickerson
    Carlos E Rochitte
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [22] MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING
    CLARKE, GD
    ECKELS, R
    CHANEY, C
    SMITH, D
    DITTRICH, J
    HUNDLEY, WG
    NESSAIVER, M
    LI, HF
    PARKEY, RW
    PESHOCK, RM
    CIRCULATION, 1995, 91 (10) : 2627 - 2634
  • [23] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique -: comparison with oximetry
    Petersen, SE
    Voigtländer, T
    Kreitner, KF
    Kalden, P
    Wittlinger, T
    Scharhag, J
    Horstick, G
    Becker, D
    Hommel, G
    Thelen, M
    Meyer, J
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (01): : 53 - 60
  • [24] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique – comparison with oximetry
    Steffen E. Petersen
    Thomas Voigtländer
    Karl-Friedrich Kreitner
    Peter Kalden
    Thomas Wittlinger
    Jürgen Scharhag
    Georg Horstick
    Dietmar Becker
    Gerhard Hommel
    Manfred Thelen
    Jürgen Meyer
    The International Journal of Cardiovascular Imaging, 2002, 18 : 53 - 60
  • [25] MR angiography of the renal artery: comparison of breath-hold two-dimensional phase-contrast cine technique with the phased-array coil and breath-hold two-dimensional time-of-flight technique with the body coil
    Masui, T
    Takehara, Y
    Igarashi, T
    Ichijo, K
    Takahashi, M
    Kaneko, M
    Nozaki, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (01) : 62 - 66
  • [26] Assessment of coronary artery blood flow velocity using breath-hold phase contrast MR angiography in patients with acute myocardial infarction
    Furber, A
    Lethimonnier, F
    Lejeune, JJ
    L'hoste, P
    Tadei, A
    Jallet, P
    Caron-Poitreau, C
    Geslin, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 340A - 340A
  • [27] THE APPLICATION OF BREATH-HOLD PHASE-VELOCITY MAPPING TECHNIQUES TO THE MEASUREMENT OF CORONARY-ARTERY FLOOD FLOW VELOCITY - PHANTOM DATA AND INITIAL IN-VIVO RESULTS
    KEEGAN, J
    FIRMIN, D
    GATEHOUSE, P
    LONGMORE, D
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 526 - 536
  • [28] Comparison between pre- and post-contrast cardiac MRI cine images: the impact on ventricular volume and strain measurement
    Tang, Lu
    Diao, Kaiyue
    Deng, Qiao
    Wu, Xi
    Peng, Pengfei
    Yue, Xun
    Wu, Tao
    Cheng, Wei
    Li, Yangjie
    Zhou, Xiaoyue
    Wetzl, Jens
    Chen, Yucheng
    Yue, Wenjun
    Sun, Jiayu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (05): : 1055 - 1064
  • [29] Comparison between pre- and post-contrast cardiac MRI cine images: the impact on ventricular volume and strain measurement
    Lu Tang
    Kaiyue Diao
    Qiao Deng
    Xi Wu
    Pengfei Peng
    Xun Yue
    Tao Wu
    Wei Cheng
    Yangjie Li
    Xiaoyue Zhou
    Jens Wetzl
    Yucheng Chen
    Wenjun Yue
    Jiayu Sun
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1055 - 1064
  • [30] Flow quantification of different cardiac shunts by using a new breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) technique
    Kalden, P
    Kreitner, KF
    Voigtlander, T
    Roberts, H
    Roberts, T
    Krummenauer, F
    Becker, D
    Wittlinger, T
    Meyer, J
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (04): : 378 - 382