Local Pulse Wave Velocity Estimation using Magnetic Plethysmograph

被引:0
|
作者
Chandrasekhar, Anand [1 ]
Joseph, Jayaraj
Sivaprakasam, Mohanasankar [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
来源
2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2013年
关键词
ARTERIAL STIFFNESS; BLOOD-PRESSURE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse Wave Velocity(PWV) is an established measure of arterial stiffness. We present a method of measuring local pulse wave velocity by the use of Magnetic Plethysmograph( MPG) sensors. The design of a Compact Single element MPG (CS-MPG) sensor is presented. The functionality of the sensor is verified by phantom experiments. The utility of this sensor for in-vivo measurements of PWV is also demonstrated. Further, a Dual-element MPG (D-MPG) for evaluation of local PWV is also presented. The error in measurement of PWV using this sensor is characterised experimentally and shown to be within acceptable limits. The ability of this dual element sensor to measure local PWV in-vivo is also demonstrated by trials on volunteers.
引用
收藏
页码:2287 / 2290
页数:4
相关论文
共 50 条
  • [41] 10.30 A Comparative Study of Methodologies for Pulse Wave Velocity Estimation
    E. Magnani
    F. Valbusa
    D. Agnoletti
    M. Rossi
    C. Bernabini
    G. Comandini
    P. Salvi
    High Blood Pressure & Cardiovascular Prevention, 2007, 14 (3) : 145 - 145
  • [42] The Aortic Pulse Wave Velocity Estimation for Arterial Stiffness Assessment
    Pilt, Kristjan
    Koeoets, Kristina
    Meigas, Kalju
    Samarin, Andrei
    Zemtsovskaja, Galina
    Viigimaa, Margus
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 294 - 297
  • [43] Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method
    Tang, Chieh-Ju
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Huang, Chih-Chung
    ULTRASONICS, 2020, 102
  • [44] Assessment of local pulse wave velocity in arteries using 2D distension waveforms
    Meinders, JM
    Kornet, L
    Brands, PJ
    Hoeks, APG
    ULTRASONIC IMAGING, 2001, 23 (04) : 199 - 215
  • [45] Assessment of local pulse wave velocity in arteries using 2D distension waveforms
    Meinders, Jan M.
    Kornet, Lilian
    Brands, Peter J.
    Hoeks, Arnold P.G.
    2001, Dynamedia Inc. (23)
  • [46] Novel non-invasive Pressure-Volume Loop measurement for local Pulse Wave Velocity estimation
    Janjua, G. M. W.
    Finlay, D. D.
    Guldenring, D.
    Hadia, R.
    McLaughlin, J.
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [47] Artificial Intelligence Estimation of Carotid-Femoral Pulse Wave Velocity using Carotid Waveform
    Tavallali, Peyman
    Razavi, Marianne
    Pahlevan, Niema M.
    SCIENTIFIC REPORTS, 2018, 8
  • [48] Artificial Intelligence Estimation of Carotid-Femoral Pulse Wave Velocity using Carotid Waveform
    Peyman Tavallali
    Marianne Razavi
    Niema M. Pahlevan
    Scientific Reports, 8
  • [49] Ultrasound for Venous Local Pulse Wave Velocity: Comparison of Pulse Transit Time Methods
    George, Navya Rose
    Manoj, Rahul
    Kiran, Raj, V
    Nabeel, P. M.
    Sivaprakasam, Mohanasankar
    Joseph, Jayaraj
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [50] Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies
    Wang, Zhen
    Yang, Yong
    Yuan, Li-jun
    Liu, Jie
    Duan, Yun-you
    Cao, Tie-sheng
    PLOS ONE, 2015, 10 (03):