Acoustic properties of dialysed kidney by scanning acoustic microscopy

被引:17
|
作者
Sasaki, H [1 ]
Saijo, Y [1 ]
Tanaka, M [1 ]
Nitta, S [1 ]
Terasawa, Y [1 ]
Yambe, T [1 ]
Taguma, Y [1 ]
机构
[1] SENDAI SHAKAIHOKEN HOSP,KIDNEY CTR,SENDAI,MIYAGI,JAPAN
关键词
acoustic microscopy; attenuation constant; sound speed; haemodialysis; renal-cell carcinoma; acquired renal cyst;
D O I
10.1093/ndt/12.10.2151
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background, A correlation between acquired renal cysts in the dialysed kidney and renal cancer has long been debated, but no changes in the physical properties of kidneys at the microscopic level have been reported. The purpose of the present study was to classify the physical properties of the kidneys of patients undergoing haemodialysis at several stages of pathology by use of the scanning acoustic microscope. Methods, Sixteen surgically excised kidneys of dialysis patients were investigated. Tissues were fixed in 10% formalin, frozen in acetone, and cut 10 mu m thick on a cryostat. We used a scanning acoustic microscope operated in the frequency range of 100-200 MHz. Attenuation constant and sound speed were measured on a two-dimensional distribution. Results, The attenuation constant for inflammatory granulation tissue was significantly higher than that for hyaline degeneration tissue (P<0.001). Sound speed was high for granulation tissue, but tended to diminish gradually for hyaline degeneration. Sound speed increased again with progression to cystic degeneration (P<0.001), but the attenuation constant remained low. When a cystic kidney contained a malignant lesion, the previously low attenuation constant rose at that site (P<0.001), and the previously high sound speed was diminished (P<0.001). Conclusion, Our data suggest that the physical properties of dialysed kidneys at different stages of pathology can be classified by their acoustic properties. Simultaneous evaluation of attenuation constant and sound speed is considered applicable to determining whether tissues contain malignant elements.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [21] ACOUSTIC GRAY SCALE FOR SCANNING ACOUSTIC MICROSCOPY AND DIAGNOSTIC ULTRASOUND
    WEGLEIN, RD
    ULTRASONIC IMAGING, 1979, 1 (01) : 89 - 100
  • [22] Digitizers improve scanning acoustic microscopy
    Gregor, P
    Tate, G
    EE-EVALUATION ENGINEERING, 2005, 44 (01): : 16 - +
  • [23] USES OF ACOUSTIC SCANNING-MICROSCOPY
    MATTHAEI, E
    VETTERS, H
    MAYR, P
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1987, 44 : 39 - 39
  • [24] SIMULTANEOUS SCANNING OPTICAL AND ACOUSTIC MICROSCOPY
    FARIDIAN, F
    WICKRAMASINGHE, HK
    ELECTRONICS LETTERS, 1983, 19 (05) : 159 - 160
  • [25] RECENT DEVELOPMENTS IN SCANNING ACOUSTIC MICROSCOPY
    SINCLAIR, DA
    SMITH, IR
    WICKRAMASINGHE, HK
    RADIO AND ELECTRONIC ENGINEER, 1982, 52 (10): : 479 - 493
  • [26] Development of a Practical Scanning Acoustic Microscopy
    Liu, Zhongzhu
    Xu, Chunguang
    Zhao, Xinyu
    Guo, Xianghui
    AUTOMATION EQUIPMENT AND SYSTEMS, PTS 1-4, 2012, 468-471 : 1128 - 1131
  • [27] FMCW TECHNIQUES IN SCANNING ACOUSTIC MICROSCOPY
    FARIDIAN, F
    SOMEKH, MG
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (03) : 400 - 400
  • [28] Scanning acoustic microscopy for material evaluation
    Yu H.
    Yu, Hyunung (peacewithu@kriss.re.kr), 1600, Springer (50):
  • [29] Scanning acoustic microscopy in porous SiC
    Ostapenko, S
    Smith, MCD
    Tarasov, I
    Wolan, JT
    Mynbaeva, M
    Goings, J
    McKeon, JCP
    Saddow, SE
    SILICON CARBIDE AND RELATED MATERIALS 2001, PTS 1 AND 2, PROCEEDINGS, 2002, 389-3 : 687 - 690
  • [30] Quantitative Scanning Acoustic Microscopy of the Cornea
    Pavlyha, Marianna
    Silverman, Ronald
    Rohrbach, Daniel
    Lloyd, Harriet O.
    Mamou, Jonathan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)