Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion

被引:8
|
作者
Wang, Xin [1 ,2 ,3 ]
Liu, Shuting [4 ]
Zhu, Mingxing [1 ,5 ]
He, Yuchao [1 ,3 ]
Wei, Zhilong [1 ,3 ]
Wang, Yingying [1 ,2 ,3 ]
Xu, Yangjie [6 ]
Pan, Hongguang [7 ]
Huang, Weimin [8 ]
Chen, Shixiong [1 ,3 ]
Li, Guanglin [1 ,3 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, CAS Key Lab Human Machine Intelligence Synergy Sys, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, Guangdong Hong Kong Macao Joint Lab Human Machine, Hong Kong, Guangdong, Peoples R China
[4] Tech Univ Munich, Dept Informat, Munich, Germany
[5] Harbin Inst Technol, Sch Elect & Informat Engn, Shenzhen, Peoples R China
[6] Univ Luxembourg, Interdisciplinary Ctr Secur Reliabil & Trust, Luxembourg, Luxembourg
[7] Shenzhen Childrens Hosp, Dept Otolaryngol, Shenzhen, Peoples R China
[8] Shenzhen Childrens Hosp, Dept Neonatol, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
wearable biosensors system; flexible non-contact electrode; electrocardiogram; monitoring; motion; RIGHT LEG CIRCUIT; ECG INTERFERENCE; DRY; INTERFACE; IMPEDANCE; DYNAMICS;
D O I
10.3389/fnins.2022.900146
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electrocardiogram (ECG) is a critical physiological indicator that contains abundant information about human heart activities. However, it is a kind of weak low-frequency signal, which is easy to be interfered by various noises. Therefore, wearable biosensors (WBS) technique is introduced to overcome this challenge. A flexible non-contact electrode is proposed for wearable biosensors (WBS) system, which is made up of flexible printed circuits materials, and can monitor the ECG signals during exercise for a long time. It uses the principle of capacitive coupling to obtain high-quality signals, and reduces the impact of external noise through active shielding; The results showed that the proposed non-contact electrode was equivalent to a medical wet electrode. The correlation coefficient was as high as 99.70 +/- 0.30% when the subject was resting, while it was as high as 97.53 +/- 1.80% during exercise. High-quality ECG could still be collected at subjects walking at 7 km/h. This study suggested that the proposed flexible non-contact electrode would be a potential tool for wearable biosensors for medical application on long-term monitoring of patients' health and provide athletes with physiological signal measurements.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A Non-Contact ECG Sensing System with Motion Artifact Equalization
    Gao, Shanqing
    Huang, Ding-Yu
    Fang, Wai-Chi
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 244 - 247
  • [42] Screen printed graphene electrodes on textile for wearable electrocardiogram monitoring
    Xu, Xiaowen
    Luo, Meng
    He, Pei
    Guo, Xiaojun
    Yang, Junliang
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (10):
  • [43] OLAM: A Wearable, Non-Contact Sensor for Continuous Heart-Rate and Activity Monitoring
    Albright, Ryan K.
    Goska, Benjamin J.
    Hagen, Tory M.
    Chi, Mike Y.
    Cauwenberghs, G.
    Chiang, Patrick Y.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5625 - 5628
  • [44] Investigation of Non-Contact Biometric System Using Capacitive Coupling Electrodes
    Mizusako, Motoki
    Yasushi, Mitsuo
    Hashimoto, Hideki
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 2775 - 2780
  • [45] Hybrid Flexible Circuit on Cotton Fabric for Wearable Electrocardiogram Monitoring
    bin Ahmad, Muhammad Anis Safwan
    Harun, Fauzan Khairi Che
    Wicaksono, Dedy H. B.
    2017 INTERNATIONAL ELECTRONICS SYMPOSIUM ON ENGINEERING TECHNOLOGY AND APPLICATIONS (IES-ETA), 2017, : 217 - 222
  • [46] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [47] Seamless and Non-Contact Health Monitoring System in Cloud Computing
    Fong, Ee-May
    Kwon, Tae-Ha
    Chung, Wan-Young
    2013 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2013, : 530 - 531
  • [48] Simulating and Testing a Non-Contact Structural Health Monitoring System
    Amies, Alexander
    Pretty, Christopher
    Rodgers, Geoffrey
    Chase, Geoffrey
    2016 12TH IEEE/ASME INTERNATIONAL CONFERENCE ON MECHATRONIC AND EMBEDDED SYSTEMS AND APPLICATIONS (MESA), 2016,
  • [49] A Printed Dipole Array Antenna for Non-contact Monitoring System
    Liang, Qiancheng
    Mpanda, Ramadhani Selemani
    Wang, Xin
    Shi, Jingjing
    Xu, Lisheng
    2018 CROSS STRAIT QUAD-REGIONAL RADIO SCIENCE AND WIRELESS TECHNOLOGY CONFERENCE (CSQRWC), 2018,
  • [50] Implementation of Face Tracking System for Non-contact Respiration Monitoring
    Lee, WonYoung
    Jung, KyungKwon
    Kim, YongJoong
    Lee, GiSeop
    Park, CheolGyu
    2012 INTERNATIONAL CONFERENCE ON FUTURE INFORMATION TECHNOLOGY AND MANAGEMENT SCIENCE & ENGINEERING (FITMSE 2012), 2012, 14 : 160 - 163