Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion

被引:8
|
作者
Wang, Xin [1 ,2 ,3 ]
Liu, Shuting [4 ]
Zhu, Mingxing [1 ,5 ]
He, Yuchao [1 ,3 ]
Wei, Zhilong [1 ,3 ]
Wang, Yingying [1 ,2 ,3 ]
Xu, Yangjie [6 ]
Pan, Hongguang [7 ]
Huang, Weimin [8 ]
Chen, Shixiong [1 ,3 ]
Li, Guanglin [1 ,3 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, CAS Key Lab Human Machine Intelligence Synergy Sys, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, Guangdong Hong Kong Macao Joint Lab Human Machine, Hong Kong, Guangdong, Peoples R China
[4] Tech Univ Munich, Dept Informat, Munich, Germany
[5] Harbin Inst Technol, Sch Elect & Informat Engn, Shenzhen, Peoples R China
[6] Univ Luxembourg, Interdisciplinary Ctr Secur Reliabil & Trust, Luxembourg, Luxembourg
[7] Shenzhen Childrens Hosp, Dept Otolaryngol, Shenzhen, Peoples R China
[8] Shenzhen Childrens Hosp, Dept Neonatol, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
wearable biosensors system; flexible non-contact electrode; electrocardiogram; monitoring; motion; RIGHT LEG CIRCUIT; ECG INTERFERENCE; DRY; INTERFACE; IMPEDANCE; DYNAMICS;
D O I
10.3389/fnins.2022.900146
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electrocardiogram (ECG) is a critical physiological indicator that contains abundant information about human heart activities. However, it is a kind of weak low-frequency signal, which is easy to be interfered by various noises. Therefore, wearable biosensors (WBS) technique is introduced to overcome this challenge. A flexible non-contact electrode is proposed for wearable biosensors (WBS) system, which is made up of flexible printed circuits materials, and can monitor the ECG signals during exercise for a long time. It uses the principle of capacitive coupling to obtain high-quality signals, and reduces the impact of external noise through active shielding; The results showed that the proposed non-contact electrode was equivalent to a medical wet electrode. The correlation coefficient was as high as 99.70 +/- 0.30% when the subject was resting, while it was as high as 97.53 +/- 1.80% during exercise. High-quality ECG could still be collected at subjects walking at 7 km/h. This study suggested that the proposed flexible non-contact electrode would be a potential tool for wearable biosensors for medical application on long-term monitoring of patients' health and provide athletes with physiological signal measurements.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Investigation of Non-contact Electrodes for Electrocardiogram Monitoring
    Hoffmann, Wagner
    Lowe, Andrew
    Wilson, Matt
    Kuo, Matthew M. Y.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [2] Development of Novel Non-contact Electrodes for Mobile Electrocardiogram Monitoring System
    Lin, Bor-Shyh
    Chou, Willy
    Wang, Hsing-Yu
    Huang, Yan-Jun
    Pan, Jeng-Shyang
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2013, 1
  • [3] Flexible Non-contact Electrodes for Bioelectrical Signal Monitoring
    Liu, Shuting
    Liu, Xueyu
    Jiang, Yanbing
    Wang, Xin
    Huang, Pingao
    Wang, Hui
    Zhu, Mingxing
    Tan, Jingqian
    Li, Peng
    Lin, Chuang
    Zhang, Guanghe
    Chen, Shixiong
    Li, Guanglin
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4305 - 4308
  • [4] Passive Continuous Electrocardiogram Monitoring of Firemen Using Non-Contact Electrodes
    Ritchie, Peter
    Huerta, Miguel
    Lau, Tuen Lung
    Agee, Jules
    Cao, Hung
    Chiao, J. -C.
    2017 IEEE SENSORS, 2017, : 1101 - 1103
  • [5] Wearable Monitoring System Based on Non-Contact Electrode
    Liu, Jihong
    Chen, Yuanjin
    Wu, Qilong
    Zhou, Yanfeng
    Qiao, Tianrun
    Sun, Bangke
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 33 - 34
  • [6] Non-contact breath motion monitoring system in full automation
    Sato, Isao
    Nakajima, Masato
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3448 - 3451
  • [7] Non-contact wearable synchronous measurement method of electrocardiogram and seismocardiogram signals
    Wang, Yifeng
    Li, Jiangtao
    Wang, Haoyue
    Yan, Zexin
    Xu, Zhengyi
    Li, Chenjie
    Zhao, Zheng
    Raza, Syed Ali
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (03):
  • [8] A Wearable Electrocardiogram Monitoring System Robust to Motion Artifacts
    Seol, Taeryoung
    Lee, Sehwan
    Lee, Junghyup
    2018 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2018, : 241 - 242
  • [9] A non-contact flexible pyroelectric sensor for wireless physiological monitoring system
    He, Jian
    Li, Sen
    Hou, Xiaojuan
    Zhou, Yongjun
    Li, Hao
    Cui, Min
    Guo, Tao
    Wang, Xiangdong
    Mu, Jiliang
    Geng, Wenping
    Chou, Xiujian
    SCIENCE CHINA-INFORMATION SCIENCES, 2022, 65 (02)
  • [10] A non-contact flexible pyroelectric sensor for wireless physiological monitoring system
    Jian He
    Sen Li
    Xiaojuan Hou
    Yongjun Zhou
    Hao Li
    Min Cui
    Tao Guo
    Xiangdong Wang
    Jiliang Mu
    Wenping Geng
    Xiujian Chou
    Science China Information Sciences, 2022, 65