Fuzzy-based Energy Management System for a MVDC PV Power Plant with Battery Stored Quasi-Z-Source Inverter

被引:1
|
作者
de Oliveira-Assis, Lais [1 ]
Soares-Ramos, Emanuel P. P. [2 ]
Garcia-Trivino, Pablo [1 ]
Sarrias-Mena, Raul [3 ]
Andres Garcia-Vazquez, Carlos [1 ]
Fernandez-Ramirez, Luis M. [1 ]
机构
[1] Univ Cadiz, Res Grp Sustainable & Renewable Elect Technol PAI, Dept Elect Engn, Algeciras, Spain
[2] Fed Ctr Technol Educ Minas Gerais, Dept Electroelect, Curvelo, MG, Brazil
[3] Univ Cadiz, Res Grp Sustainable & Renewable Elect Technol PAI, Dept Engn Automat Elect & Comp Architecture & Net, Algeciras, Spain
关键词
Photovoltaic (PV); medium voltage direct current (MVDC); energy storage system; quasi-Z-source inverter (qZSI); fuzzy logic control; CONTROLLER;
D O I
10.1109/EEEIC/ICPSEurope51590.2021.9584829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Renewable energy systems based on photovoltaic (PV) power plants are usually connected to the grid through a DC-DC boost converter and a voltage source inverter. In this paper, this topology is modified by replacing this conversion system consisting of two stages for one of single stage, employing a quasi-Z-source inverter (qZSI), which allows to achieve a medium voltage direct current (MVDC) at the output of the Z source. In addition, a battery is integrated directly into the qZSI, without any additional DC/DC converter, which is used to support the intermittence of the PV generation and improve the operability of the system. The PV power plant operates at maximum power point tracking (MPPT) and the active and reactive power delivered by the PV power plant through the qZSI are controlled by a Z-Space Vector Modulation (ZSVM) technique. An energy management system (EMS) based on a fuzzy logic controller is implemented for the supervisory control of the PV plant and battery. The EMS decides to charge or discharge the battery depending on the power generated by PV power plant, the battery state-of-charge (SoC), and the grid energy price. The main advantages of the proposed system are: (i) the use of a single stage conversion; (ii) the battery connection directly to the Z source, which allows not to use an additional DC/DC converter; (iii) the application of fuzzy logic control for the EMS, while maintaining the battery within secure SoC limits and with a smooth response. The results illustrate the proper behavior of the PV power plant under different operating conditions.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] 1-MW Quasi-Z-Source based Multilevel PV Energy Conversion System
    Trabelsi, Mohamed
    Abu-Rub, Haitham
    Ge, Baoming
    PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 224 - 229
  • [32] Quasi-Z-Source Inverter for Photovoltaic Power Generation Systems
    Li, Yuan
    Anderson, Joel
    Peng, Fang Z.
    Liu, Dichen
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 918 - +
  • [33] Modeling and system parameter design method for single-phase energy-stored quasi-Z-source inverter
    Cheng J.
    Li Y.
    Xiao X.
    Cheng, Jun (574111026@qq.com), 1600, Power System Protection and Control Press (48): : 128 - 136
  • [34] Fuzzy Control Design for Quasi-Z-Source Three Phase Inverter
    Hamed, Basil
    Qaoud, Nouh A.
    2019 IEEE 7TH PALESTINIAN INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (PICECE), 2019,
  • [35] An Asymmetrical Dual Quasi-Z-Source Based 7-Level Inverter for PV Applications
    Manoj, P.
    Kirubakaran, A.
    Somasekhar, V. T.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (02) : 1097 - 1107
  • [36] Designing a Quasi-Z-Source Inverter with Energy Storage to Improve Grid Power Quality
    Honarbari, S.
    Bidgoli, M. Alizadeh
    IETE JOURNAL OF RESEARCH, 2022, 68 (04) : 2445 - 2453
  • [37] High-performance hybrid photovoltaic -battery system based on quasi-Z-source inverter: application in microgrids
    Khajesalehi, Jasem
    Sheshyekani, Keyhan
    Hamzeh, Mohsen
    Afjei, Ebrahim
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (10) : 895 - 902
  • [38] Research on the Composite Control for PV Grid-connected and Energy-storage based on Quasi-Z-source inverter
    Su, Baozhen
    Gu, Herong
    Wang, Yuerong
    Zhao, Wei
    2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 572 - 577
  • [39] Power Conditioning System for a Grid Connected PV Power Generation Using a Quasi-Z-Source
    Park, Jong-Young
    Kim, Heung-Geun
    Nho, Eui-Cheol
    Chun, Tae-Won
    JOURNAL OF POWER ELECTRONICS, 2010, 10 (01) : 79 - 84
  • [40] Bidirectional Quasi-Z-Source Inverter with Hybrid Energy Storage for IM Drive System
    Muhammad, Masitah
    Rasin, Zulhani
    Jidin, Auzani
    2019 IEEE 9TH SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS (ISCAIE), 2019, : 75 - 80