Pertraction of penicillin G in hollow fiber contained liquid membranes

被引:6
|
作者
Miesiac, I [1 ]
Szymanowski, J [1 ]
机构
[1] Poznan Tech Univ, Inst Chem Technol & Engn, PL-60965 Poznan, Poland
关键词
D O I
10.1007/BF02387303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pertraction of Penicillin G in Hollow Fiber Contained Liquid Membranes was investigated in a system consisting of 2 Liqui Cel 106 modules from Hoechst Celanese. The flux of Pen G depended upon the content of n-octanol and of Amberlite LA2 in kerosene used as a membrane phase. During the pertraction of Pen G in HFCLM system the pH difference between the both buffered aqueous phases diminished proportionally to the contact time with the membrane phase. The flux of citric acid used as a buffer component in the feed phase attained 11.8 mM/m(2).h and was comparable with the flux of Pen G equal to 18.4 mM/m(2).h. In order to eliminate the undesired transport of citric acid, CO2 was used as a volatile buffer component. Although the pH values were stabilised in the range of 5.47 and 7.45 in the feed and strip phase, respectively, the achieved Pen G flux was significantly lower.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [31] Fabrication of porous attapulgite hollow fiber membranes for liquid filtration
    Li, Meisheng
    Zhou, Shouyong
    Xue, Ailian
    Su, Tingting
    Zhang, Yan
    Zhao, Yijiang
    Xing, Weihong
    MATERIALS LETTERS, 2015, 161 : 132 - 135
  • [32] Use of emulsions, microemulsions, and hollow fiber contactors as liquid membranes
    Wiencek, JM
    Hu, SY
    Raghuraman, B
    CHEMICAL SEPARATIONS WITH LIQUID MEMBRANES, 1996, 642 : 319 - 328
  • [33] Computational analysis of citric acid pertraction in emulsion liquid membranes
    Ghanbari, Saeed
    Golmohammadi, Morteza
    Gostick, Jeff
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2023, 101 (06): : 3607 - 3623
  • [34] A mathematical model for pertraction of uranium in hollow fiber contactor using TBP
    Dixit, Smita
    Mukhopadhyay, S.
    Govalkar, Smita
    Shenoy, K. T.
    Rao, H.
    Ghosh, S. K.
    DESALINATION AND WATER TREATMENT, 2012, 38 (1-3) : 195 - 206
  • [35] Mass transfer of cadmium ions in a hollow-fiber module by pertraction
    Marchese, J
    Campderrós, M
    DESALINATION, 2004, 164 (02) : 141 - 149
  • [36] SEPARATION OF LIQUID SOLUTIONS BY CONTAINED LIQUID MEMBRANES
    SENGUPTA, A
    BASU, R
    PRASAD, R
    SIRKAR, KK
    SEPARATION SCIENCE AND TECHNOLOGY, 1988, 23 (12-13) : 1735 - 1751
  • [37] Pertraction of Acetaminophen through Bulk Liquid Membranes Kinetic aspects
    Diaconu, Ioana
    Mirea, Cristina Monica
    Serban, Ecaterina Anca
    Ruse, Elena
    Nechifor, Gheorghe
    REVISTA DE CHIMIE, 2015, 66 (07): : 926 - 928
  • [38] A model for metal ion pertraction through supported liquid membranes
    Mohammadi, Samira
    Kaghazchi, Tahereh
    Kargari, Ali
    DESALINATION, 2008, 219 (1-3) : 324 - 334
  • [39] Gas permeability of hollow fiber membranes in a gas-liquid system
    Lund, LW
    Federspiel, WJ
    Hattler, BG
    JOURNAL OF MEMBRANE SCIENCE, 1996, 117 (1-2) : 207 - 219
  • [40] TRANSPORT OF STRONTIUM CATION THROUGH HOLLOW FIBER SUPPORTED LIQUID MEMBRANES
    MIKULAJ, V
    RAJEC, P
    SVEC, A
    MACKOVA, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1993, 175 (04): : 287 - 296