Personalized Pre- and Post-Operative Hemodynamic Assessment of Aortic Coarctation from 3D Rotational Angiography

被引:6
|
作者
Nita, Cosmin-Ioan [1 ,2 ]
Puiu, Andrei [1 ,2 ]
Bunescu, Daniel [1 ,2 ]
Itu, Lucian Mihai [1 ,2 ]
Mihalef, Viorel [3 ]
Chintalapani, Gouthami [4 ]
Armstrong, Aimee [5 ]
Zampi, Jeffrey [6 ]
Benson, Lee [7 ]
Sharma, Puneet [3 ]
Rapaka, Saikiran [3 ]
机构
[1] Siemens SRL, Advanta, 3A Eroilor, Brasov 500007, Romania
[2] Transilvania Univ Brasov, Automat & Informat Technol, 5 Mihai Viteazu, Brasov 5000174, Romania
[3] Siemens Healthineers, Digital Serv Digital Technol & Innovat, 755 Coll Rd, Princeton, NJ 08540 USA
[4] Siemens Healthineers, Adv Therapies, Malvern, PA USA
[5] Nationwide Childrens Hosp, Heart Ctr, Columbus, OH USA
[6] Univ Michigan, Div Pediat Cardiol, Ann Arbor, MI 48109 USA
[7] Hosp Sick Children, Labatt Family Heart Ctr, Div Cardiol, Toronto, ON, Canada
基金
欧盟地平线“2020”;
关键词
Hemodynamic modelling; Machine learning; Aortic coarctation; Parameter estimation framework; 3D Rotational Angiography; COMPUTATIONAL FLUID-DYNAMICS; MACHINE-LEARNING APPROACH; FRACTIONAL FLOW RESERVE; HUMAN ARTERIAL NETWORK; BLOOD-FLOW; FOLLOW-UP; VALIDATION; MODEL; SIMULATIONS; PREDICTION;
D O I
10.1007/s13239-021-00552-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Coarctation of Aorta (CoA) is a congenital disease consisting of a narrowing that obstructs the systemic blood flow. This proof-of-concept study aimed to develop a framework for automatically and robustly personalizing aortic hemodynamic computations for the assessment of pre- and post-intervention CoA patients from 3D rotational angiography (3DRA) data. Methods-We propose a framework that combines hemodynamic modelling and machine learning (ML) based techniques, and rely on 3DRA data for non-invasive pressure computation in CoA patients. The key features of our framework are a parameter estimation method for calibrating inlet and outlet boundary conditions, and regional mechanical wall properties, to ensure that the computational results match the patient-specific measurements, and an improved ML based pressure drop model capable of predicting the instantaneous pressure drop for a wide range of flow conditions and anatomical CoA variations. Results-We evaluated the framework by investigating 6 patient datasets, under pre- and post-operative setting, and, since all calibration procedures converged successfully, the proposed approach is deemed robust. We compared the peak-to-peak and the cycle-averaged pressure drop computed using the reduced-order hemodynamic model with the catheter based measurements, before and after virtual and actual stenting. The mean absolute error for the peak-to-peak pressure drop, which is the most relevant measure for clinical decision making, was 2.98 mmHg for the pre- and 2.11 mmHg for the post-operative setting. Moreover, the proposed method is computationally efficient: the average execution time was of only 2.1 +/- 0.8 minutes on a standard hardware configuration. Conclusion-The use of 3DRA for hemodynamic modelling could allow for a complete hemodynamic assessment, as well as virtual interventions or surgeries and predictive modeling. However, before such an approach can be used routinely, significant advancements are required for automating the workflow.
引用
收藏
页码:14 / 40
页数:27
相关论文
共 50 条
  • [21] Pre- and Post-Operative Nutrition Assessment in Patients with Colon Cancer Undergoing Ileostomy
    Vasilopoulos, Georgios
    Makrigianni, Panagiota
    Polikandrioti, Maria
    Tsiampouris, Ilias
    Karayiannis, Dimitrios
    Margari, Nikoletta
    Avramopoulou, Lamprini
    Toulia, Georgia
    Fasoi, Georgia
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (17) : 1 - 10
  • [22] Cardiac surgery: Pre- & post-operative insights from MR & CT
    White, Richard
    CIRCULATION, 2006, 114 (18) : F - F
  • [23] Intravascular ultrasonic assessment of post-operative remodelling of aortic coarctation repaired by use of a subclavian flap
    Shimizu, T
    Satomi, G
    Yasukochi, S
    CARDIOLOGY IN THE YOUNG, 2003, 13 (01) : 53 - 57
  • [24] VALUE OF SPIRAL CT ANGIOGRAPHY AND 3D RECONSTRUCTION OF AORTIC COARCTATION
    BECKER, CR
    SOPPA, C
    FINK, U
    HAUBNER, M
    REISER, MF
    RADIOLOGY, 1995, 197 : 336 - 336
  • [25] 3D Inception-Based TransMorph: Pre- and Post-operative Multi-contrast MRI Registration in Brain Tumors
    Abderezaei, Javid
    Pionteck, Aymeric
    Chopra, Agamdeep
    Kurt, Mehmet
    BRAINLESION: GLIOMA, MULTIPLE SCLEROSIS, STROKE AND TRAUMATIC BRAIN INJURIES, BRAINLES 2022, PT II, 2023, 14092 : 35 - 45
  • [26] Spiral CT angiography and 3D reconstruction in patients with aortic coarctation
    Becker, C
    Soppa, C
    Fink, U
    Haubner, M
    MullerLisse, U
    Englmeier, KH
    Buhlmeyer, K
    Reiser, M
    EUROPEAN RADIOLOGY, 1997, 7 (09) : 1473 - 1477
  • [27] Spiral CT angiography and 3D reconstruction in patients with aortic coarctation
    C. Becker
    C. Soppa
    U. Fink
    M. Haubner
    U. Müller-Lisse
    K. H. Englmeier
    K. Bühlmeyer
    M. Reiser
    European Radiology, 1997, 7 : 1473 - 1477
  • [28] Pre- and Post-Operative Stroke Volume Impact After Surgical Aortic Valve Replacement for Severe Aortic Stenosis
    Guzzetti, Ezequiel
    Poulin, Anthony
    Annabi, Mohamed-Salah
    Kalavrouziotis, Dimitri
    Dagenais, Francois
    Pibarot, Philippe
    Clavel, Marie-Annick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : 2036 - 2038
  • [29] The Role of Myocardial Strain Imaging in the Pre- and Post-Operative Assessment of Patients with Single Ventricle
    Kleitsioti, Panagiota
    Koulaouzidis, George
    Giannakopoulou, Pinelopi
    Charisopoulou, Dafni
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (05)
  • [30] From pre- operative comorbidities to post-operative cognitive dysfunction: The challenging face of geriatric anaesthesia
    Bhaskar, S. Bala
    Bajwa, Sukhminder Jit Singh
    INDIAN JOURNAL OF ANAESTHESIA, 2014, 58 (03) : 248 - 250