Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al2O3 Nanofluid

被引:33
|
作者
Ju, Yongfeng [1 ]
Zhu, Tiezhu [1 ]
Mashayekhi, Ramin [2 ]
Mohammed, Hayder, I [3 ]
Khan, Afrasyab [4 ]
Talebizadehsardari, Pouyan [5 ]
Yaici, Wahiba [6 ]
机构
[1] Huaiyin Inst Technol, Fac Elect Informat Engn, Huaian 223003, Peoples R China
[2] Islamic Azad Univ, Khomeinishahr Branch, Young Researchers & Elite Club, Khomeinishahr 11984175, Iran
[3] Univ Garmian, Coll Educ, Dept Phys, Kurdistan 46021, Kalar, Iraq
[4] South Ural State Univ, Inst Engn & Technol, Dept Hydraul & Hydraul & Pneumat Syst, Lenin Prospect 76, Chelyabinsk 454080, Russia
[5] Brunel Univ London, Ctr Sustainable Energy Use Food Chains, Inst Energy Futures, Kingston Lane, Uxbridge UB8 3PH, Middx, England
[6] Nat Resources Canada, CanmetENERGY Res Ctr, 1 Haanel Dr, Ottawa, ON K1A 1M1, Canada
关键词
twisted tape inserts; nanofluid; performance evaluation criterion; heat exchanger pipe; Nusselt number; friction factor; PARABOLIC SOLAR COLLECTOR; QUANTITY LUBRICATION; PERFORMANCE-CHARACTERISTICS; TRANSFER ENHANCEMENT; FORCED-CONVECTION; ENERGY DEMAND; WATER-HEATER; FLOW; TUBES; EFFICIENCY;
D O I
10.3390/nano11061570
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al2O3/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Performance prediction and evaluation of heat pipe with hexagonal perforated twisted tape inserts
    Kadbhane, Snehal Vasant
    Pangavhane, Dilip R.
    HEAT AND MASS TRANSFER, 2024, 60 (06) : 987 - 1008
  • [32] Thermal performance of double pipe heat exchanger with V-cut twisted Tape inserts
    Singh, Sumit Kr.
    Sarkar, Jahar
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [33] Performance prediction and evaluation of heat pipe with hexagonal perforated twisted tape inserts
    Snehal Vasant Kadbhane
    Dilip R. Pangavhane
    Heat and Mass Transfer, 2024, 60 : 987 - 1008
  • [34] Heat Transfer and Friction Factor of Al2O3 Nanofluid Flow in a Double Pipe U-Tube Heat Exchanger and with Longitudinal Strip Inserts: An Experimental Study
    Prasad, P. V. Durga
    Gupta, A. V. S. S. K. S.
    Sundar, L. Syam
    Singh, Manoj Kumar
    Sousa, Antonio C. M.
    JOURNAL OF NANOFLUIDS, 2015, 4 (03) : 293 - 301
  • [35] Numerical study of turbulent nanofluid heat transfer in a tubular heat exchanger with twin twisted-tape inserts
    Rahim Hosseinnezhad
    Omid Ali Akbari
    Hamid Hassanzadeh Afrouzi
    Mohit Biglarian
    Ali Koveiti
    Davood Toghraie
    Journal of Thermal Analysis and Calorimetry, 2018, 132 : 741 - 759
  • [36] Numerical study of turbulent nanofluid heat transfer in a tubular heat exchanger with twin twisted-tape inserts
    Hosseinnezhad, Rahim
    Akbari, Omid Ali
    Afrouzi, Hamid Hassanzadeh
    Biglarian, Mohit
    Koveiti, Ali
    Toghraie, Davood
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 132 (01) : 741 - 759
  • [37] Improving hydrothermal performance of double-tube heat exchanger with modified twisted tape inserts using hybrid nanofluid
    Singh, Sumit Kr.
    Sarkar, Jahar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 143 (06) : 4287 - 4298
  • [38] Improving hydrothermal performance of double-tube heat exchanger with modified twisted tape inserts using hybrid nanofluid
    Sumit Kr. Singh
    Jahar Sarkar
    Journal of Thermal Analysis and Calorimetry, 2021, 143 : 4287 - 4298
  • [39] Experimental and Numerical Study of Heat Transfer in Double-Pipe Heat Exchanger Using Al2O3, and TiO2 Water Nanofluid
    Mund, Abhishek
    Pattanayak, Bikash
    Jayakumar, J. S.
    Parashar, Kajal
    Parashar, S. K. S.
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 531 - 540
  • [40] Heat transfer augmentation in a double-pipe heat exchanger with dimpled twisted tape inserts: an experimental study
    Soltani, Mohammad Mohsen
    Gorji-Bandpy, Mofid
    Vaisi, Ahmad
    Moosavi, Rouhollah
    HEAT AND MASS TRANSFER, 2022, 58 (09) : 1591 - 1606