On-chip Structure for Optofluidic Sensing using Stable Fabry-Perot Resonator

被引:1
|
作者
Toraya, Abdelrahman [1 ]
Gaber, Noha [1 ,2 ]
Marty, Frederic [2 ]
Bourouina, Tarik [2 ]
机构
[1] Zewail City Sci & Technol, Ctr Nanotechnol, Giza 12578, Egypt
[2] Univ Paris Est, Lab Elect Syst Commun & Microsyst, ESIEE Paris, ESYCOM EA 2552, F-93162 Noisy Le Grand, France
来源
关键词
Fabry-Perot microcavity; integrated optical resonator; optofluidic sensor; on-chip refractometer; LABEL-FREE DETECTION; SYSTEMS;
D O I
10.1117/12.2582696
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Miniaturizing optical resonators on-chip offers employing them in lab-on-chip sensing devices, which achieves portability, lower price, and only finger prick sample sizes. However, the chip microfabrication limitation may impose some challenges. Taking the Fabry-Perot cavity, the mirrors ideally should have curved shape in 3D to match the light-beam wave front to achieve good light confinement inside the resonator. But as 3D curvature is challenging to fabricate on-chip, straight mirrors are usually used instead with short cavity lengths to avoid high diffraction loss with the beams' multiple trips between the 2 mirrors. The short length limits the sample space between the mirrors, so it can't accommodate large samples such as some types of biological cells. In previous work, the curvature is divided on 2 plans by using cylindrical mirrors for the horizontal plan confinement, and a fiber-rod-lens for the vertical plan confinement. That scheme achieved good light stability; but the curved mirrors produced side peaks as higher order resonance modes, which put limitation on the sensor range. In this work, a novel design is introduced to overcome this limitation by using straight mirrors instead of curved ones, and use an upright cylindrical lens to confine the light in the transverse direction before the cavity. The novel structure is designed by analytical modeling, and verified by numerical simulations. The cavity lengths are typically of tens of micrometers and can reach hundreds, allowing the fluidic channel to hold large test samples. The chip is fabricated in silicon, then fiber-rod-lenses are simply added post-fabrication.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Ferrite disk - Resonator Fabry-Perot
    Polupanov, VN
    Kuleshov, YM
    Dakhov, NF
    Polupanova, AV
    2000 25TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES CONFERENCE DIGEST, 2000, : 427 - 428
  • [42] FABRY-PEROT RESONATOR .2.
    LOTSCH, HKV
    OPTIK, 1969, 28 (04): : 328 - &
  • [43] Optofluidic laser array based on stable high-Q Fabry-Perot microcavities
    Wang, Wenjie
    Zhou, Chunhua
    Zhang, Tingting
    Chen, Jingdong
    Liu, Shaoding
    Fan, Xudong
    LAB ON A CHIP, 2015, 15 (19) : 3862 - 3869
  • [44] Ultrasensitive optofluidic coupled Fabry-Perot capillary sensors
    Zhao, Xuyang
    Zhou, Yi
    LI, Yuxiang
    Guo, Junhong
    Liu, Zhiran
    Luo, Man
    Guo, Zhihe
    Yang, Xi
    Zhang, Meng
    Wang, You
    Wu, Xiang
    OPTICS EXPRESS, 2022, 30 (25) : 45070 - 45081
  • [46] NONLINEAR FIBER FABRY-PEROT RESONATOR USING THERMOOPTIC EFFECT
    OGUSU, K
    YAMAMOTO, S
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1993, 11 (11) : 1774 - 1781
  • [47] Design broadband Fabry-Perot Resonator Antenna using Quasi-Periodic Structure
    Liu, Zhen-Guo
    PROCEEDINGS OF THE 2008 INTERNATIONAL WORKSHOP ON METAMATERIALS, 2008, : 259 - 262
  • [49] On-chip Fabry-Perot interferometric sensors for micro-gas chromatography detection
    Reddy, Karthik
    Guo, Yunbo
    Liu, Jing
    Lee, Wonsuk
    Oo, Maung Kyaw Khaing
    Fan, Xudong
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 159 (01): : 60 - 65
  • [50] Polymer-functionalized on-chip Fabry-Perot interferometer for CO2 and CH4 sensing
    Guertin, Regis
    Bianki, Marc-Antoine
    Figueroa, Ocdane
    Amoah, Cephas
    Skene, William
    Peter, Yves-Alain
    2024 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, OMN, 2024,