Practical cases of electric field distribution along dry and clean nonceramic insulators of high-voltage power lines

被引:19
|
作者
Que, Weiguo
Sebo, Stephen A.
Hill, Robert J.
机构
[1] Ohio State Univ, Columbus, OH 43210 USA
[2] MacLean Power Syst, Franklin Park, IL 60131 USA
关键词
electric field and voltage distributions; insulator model setup; nonceramic insulators; verification tests;
D O I
10.1109/TPWRD.2007.893190
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High electric field strength may cause problems, such as corona and deterioration, on nonceramic insulators. Therefore, control of the electric field strength (E) in the vicinity of such insulators is an important aspect for their design. This paper discusses insulator computation models and their applications to 34.5 kV and 765 kV nonceramic insulators. Possible model simplifications are reviewed and discussed. Various 765 kV insulator designs and tower types are covered; the magnitude and distribution of E are reviewed. Verification tests are also described.
引用
收藏
页码:1070 / 1078
页数:9
相关论文
共 50 条
  • [21] FINITE ELEMENT MODELING FOR ELECTRIC FIELD AND VOLTAGE DISTRIBUTION ALONG THE CAP AND PIN INSULATORS UNDER POLLUTION
    Ghermoul O.
    Benguesmia H.
    Benyettou L.
    Diagnostyka, 2023, 24 (02):
  • [22] Evaluation of the Electric and Magnetic Field near High Voltage Power Lines
    Braicu, S. F.
    Czumbil, L.
    Stet, D.
    Micu, D. D.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2016, 2017, 59 : 141 - 146
  • [23] Electric Field Mitigation under Extra High Voltage Power Lines
    Radwan, R. M.
    Mahdy, A. M.
    Abdel-Salam, M.
    Samy, M. M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (01) : 54 - 62
  • [24] The usage of harmonic electric field on detecting faulty insulators on high voltage DC transmitting lines
    Cheng, YC
    Li, CR
    Qiu, DF
    Zhang, Y
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 514 - 517
  • [25] Analysis of electric and magnetic field intensity generated by overhead power distribution lines of high voltage in Poznan
    Nadolny, Zbigniew
    Grzybowski, Andrzej
    Kasprzak, Wojciech
    Ludwikowski, Karol
    Lopatkiewicz, Radoslaw
    Moranda, Hubert
    Przybylek, Piotr
    Sikorski, Wojciech
    Siodla, Krzysztof
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 254 - 257
  • [26] Analysis of electric field distribution in high-voltage solid insulation with gas inclusions
    Phuc, TK
    ELECTRICAL TECHNOLOGY, 1995, (04): : 151 - 162
  • [27] Environmental justice: A contrary finding for the case of high-voltage electric power transmission lines
    Wartenberg, Daniel
    Greenberg, Michael R.
    Harris, Gerald
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2010, 20 (03) : 237 - 244
  • [28] PREDICTION AND IMPROVEMENT OF THE ELECTRIC-FIELD DISTRIBUTION IN HIGH-VOLTAGE AC SUBSTATIONS
    YAN, Z
    LI, JX
    DONG, ZY
    ZHU, Y
    ELECTRIC POWER SYSTEMS RESEARCH, 1986, 11 (02) : 153 - 159
  • [29] EFFECT OF THE ELECTRIC-FIELD OF HIGH-VOLTAGE TRANSMISSION-LINES ON LAND INVERTEBRATES
    ORLOV, VM
    BABENKO, AS
    SOVIET JOURNAL OF ECOLOGY, 1987, 18 (06) : 267 - 274
  • [30] Analysis of electric and magnetic fields in the vicinity of 400 kV high-voltage power lines
    Ferlic, Rado
    Trlep, Mladen
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2007, 74 (1-2): : 1 - 6