Synchrotron radiation computed laminography using an inclined detector

被引:0
|
作者
Zhang, Jie [1 ]
Li, Gang [1 ]
Yi, Qiru [1 ]
Chen, Yu [1 ]
Gao, Zhenhua [1 ]
Jiang, Xiaoming [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
基金
美国国家科学基金会;
关键词
computed laminography; inclining detector; TOMOGRAPHY;
D O I
10.1107/S1600577514021754
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Synchrotron radiation computed laminography (SR-CL) has been in use in three-dimensional non-destructive imaging of flat objects for several years. A new set-up is proposed based on the traditional SR-CL method but with the detector inclined at the same angle as the sample inclination to collect projections. The results of computer simulations and real-sample experiments demonstrate that reconstructions acquired using an inclined detector are of better quality compared with those acquired using ordinary detecting methods, especially for the situation of few projections and small difference of attenuation ratio of the sample. This method could be applied to obtain high-quality images of weak-contrast samples with short measurement time and mild radiation damage.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [31] Computed laminography for materials testing
    Zhou, J
    Maisl, M
    Reiter, H
    Arnold, W
    APPLIED PHYSICS LETTERS, 1996, 68 (24) : 3500 - 3502
  • [32] Orthogonal Translation Computed Laminography
    Tian Zhongjian
    Yu Haijun
    Wang Linbo
    Pi Zhenzhen
    Liu Fenglin
    ACTA OPTICA SINICA, 2020, 40 (22)
  • [33] Computed laminography and reconstruction algorithm
    Que Jie-Min
    Cao Da-Quan
    Zhao Wei
    Tang Xiao
    Sun Cui-Li
    Wang Yan-Fang
    Wei Cun-Feng
    Shi Rong-Jian
    Wei Long
    Yu Zhong-Qiang
    Yan Yong-Lian
    CHINESE PHYSICS C, 2012, 36 (08) : 777 - 783
  • [34] Computed laminography and reconstruction algorithm
    阙介民
    曹大泉
    赵维
    唐晓
    孙翠丽
    王燕芳
    魏存峰
    史戎坚
    魏龙
    郁忠强
    阎永廉
    中国物理C, 2012, 36 (08) : 777 - 783
  • [35] Evaluation of Radiation Dose Effects on Rat Bones Using Synchrotron Radiation Computed Microtomography
    Nogueira, Liebert Parreiras
    Barroso, Regina Cely
    Braz, Delson
    de Almeida, Carlos Eduardo
    Andrade, Cherley Borba
    Tromba, Giuliana
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [36] In-situ 3D visualization of compression process for powder beds by synchrotron-radiation X-ray computed laminography
    Yokota, Maria
    Kusano, Takumi
    Mori, Mikiya
    Okuda, Katsuharu
    Matsunaga, Takuro
    POWDER TECHNOLOGY, 2021, 380 : 265 - 272
  • [37] PROPERTIES OF AN INCLINED DOUBLE CRYSTAL MONOCHROMATOR FOR SYNCHROTRON RADIATION
    HRDY, J
    PACHEROVA, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (2-3): : 605 - 611
  • [38] High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography -: art. no. 071915
    Helfen, L
    Baumbach, T
    Mikulík, P
    Kiel, D
    Pernot, P
    Cloetens, P
    Baruchel, J
    APPLIED PHYSICS LETTERS, 2005, 86 (07) : 1 - 3
  • [39] In Situ Testing Using Synchrotron Radiation Computed Tomography in Materials Research
    Xinchen Ni
    Nathan K. Fritz
    Brian L. Wardle
    MRS Advances, 2019, 4 : 2831 - 2841
  • [40] Characterization of polyurethane scaffolds using synchrotron radiation based computed microtomography
    Donath, T
    Beckmann, F
    Heijkants, RGJC
    Brunke, O
    Schreyer, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 775 - 782