A Highly Accurate Measurement of Liquid Crystal Material and Device Parameters

被引:0
|
作者
Ishinabe, Takahiro [1 ]
Uchida, Tatsuo [1 ]
机构
[1] Tohoku Univ, Dept Elect, Grad Sch Engn, Aoba Ku, Sendai, Miyagi 9808579, Japan
关键词
Alignment distribution; field sequential color LCD; liquid crystal; OCB-mode; polar anchoring strength; refractive indices; ANISOTROPIC REFRACTIVE-INDEXES; POLAR ANCHORING STRENGTH; WALL INTERFACE; RENORMALIZED ELLIPSOMETRY; ENERGY; CELL;
D O I
10.1080/15421400903409374
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A highly accurate measurement method for the refractive indices of liquid crystal materials, the alignment distribution and the surface polar anchoring strength was devised by considering the multiple reflections and the interferences in the LC cell. Based on the accurate evaluation of LC devices, we developed the high-quality field sequential color liquid crystal display with a wide viewing angle and high contrast ratio.
引用
收藏
页码:211 / 227
页数:17
相关论文
共 50 条
  • [31] A highly accurate method for measuring the ordinary and extraordinary refractive indices of liquid crystal materials
    Ohno, Y.
    Ishinabe, T.
    Miyashita, T.
    Uchida, T.
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 47 - 50
  • [32] Development of a whole liquid egg certified reference material for accurate measurement of enrofloxacin residue
    Yang, Mengrui
    Liu, Fang
    Wang, Min
    Zhou, Jian
    Zhang, Liyuan
    Wang, Tongtong
    FOOD CHEMISTRY, 2020, 309
  • [33] The synthesized measurement platform of parameters of liquid crystal based on virtual instruments
    Zhao, HL
    Liu, Z
    Jiang, HL
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 1909 - 1911
  • [34] HIGHLY ACCURATE VOLUME AND MASS MEASUREMENT OF LIQUID AND GASEOUS PRODUCTS IN TRANSPORT AND PROCESS OPTIMIZATION
    KASTNER, HJ
    ERDOL & KOHLE ERDGAS PETROCHEMIE, 1978, 31 (09): : 443 - 443
  • [35] Optimization of Device Parameters for Minimizing Spherical Aberration and Astigmatism in Liquid Crystal Microlenses
    Michinori Honma
    Toshiaki Nose
    Susumu Sato
    Optical Review, 1999, 6 : 139 - 143
  • [36] Optimization of device parameters for minimizing spherical aberration and astigmatism in liquid crystal microlenses
    Honma, M
    Nose, T
    Sato, S
    OPTICAL REVIEW, 1999, 6 (02) : 139 - 143
  • [37] LIQUID-CRYSTAL CONTACT-LENS DEVICE FOR MEASUREMENT OF CORNEAL TEMPERATURE
    KINN, JB
    TELL, RA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (05) : 387 - 388
  • [38] Fast and accurate measurement of liquid crystal tilt bias angle with ELDIM EZContrast system
    Moreau, O
    Leroux, T
    POLARIZATION AND COLOR TECHNIQUES IN INDUSTRIAL INSPECTION, 1999, 3826 : 236 - 241
  • [39] The device of measurement of parameters of holograms
    Litvinenko, AS
    Shelekhov, AA
    LFNM 2004: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON LASER AND FIBER-OPTICAL NETWORKS MODELING, 2004, : 302 - 304
  • [40] Accurate measurement of intraocular lens parameters
    Vannoni, Maurizio
    Molesini, Giuseppe
    Mencucci, Rita
    Volpe, Roberto
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION V, PTS 1 AND 2, 2007, 6616