Evaluation of the separation of steroids in combined forms by RP HPLC with UV-detection and gas chromatography

被引:0
|
作者
Tsvetkova, D. [1 ]
Obreshkova, D. [1 ,2 ]
Ivanova, S. [1 ,2 ]
Hadjieva, B. [3 ]
机构
[1] Med Univ Sofia, Fac Pharm, Dept Pharmaceut Chem, 2 Dunav Str, Sofia 1000, Bulgaria
[2] Med Univ Plovdiv, Fac Pharm, Dept Pharmacognosy & Pharmaceut Chem, 15A Vasil Aprilov Str, Plovdiv 4002, Bulgaria
[3] Med Univ Plovdiv, Coll Med, 15A Vasil Aprilov Str, Plovdiv 4002, Bulgaria
来源
BULGARIAN CHEMICAL COMMUNICATIONS | 2017年 / 49卷 / 02期
关键词
Estradiol; RP HPLC; UV-detection; GC; combined forms; BONE-MINERAL DENSITY; POSTMENOPAUSAL OSTEOPOROSIS; PHARMACEUTICAL-PREPARATIONS; ESTRADIOL VALERATE; RANDOMIZED-TRIAL; WOMEN; FRACTURES; ALENDRONATE; VALIDATION; MASS;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of the current study is the evaluation of the separation of steroids from accompanying substances in drug products as follows: estradiol hemihydrate from didrogesterone (in Femoston tabl.) and estradiol valerate from levonorgestrel (in Climonorm tabl.) and ciproterone acetate (in Climen tabl.). Reversed phase (RP) HPLC with UV-detection and gas chromatography were applied. For the RP HPLC method with UV-detection the following conditions were used: a) column: Nova Pack C-18; isocratic elution with mobile phase: acetonitrile : methanol : water = 40 : 5 : 55 v/v/v; flow rate: 1 ml/min; UV-detection at lambda = 204 nm; b) column Nova Pack C-18; gradient elution with: 0-10 min: acetonitrile : methanol : water = 35 : 5 : 60 v/v/v; 10-20 min; acetonitrile : methanol : water = 70 : 5 : 25 v/v/v, flow rate: 1 ml/min, UV-detection at lambda = 230 nm. Although RP-HPLC separation at isocratic conditions allows determination of estradiol hemihydrate with high reproducibility with the highest sensitivity at lambda= 204 nm, the analysis in medicinal products requires additional time for elution of components more non-polar than estradiol hemihydrate, which are present in the sample: in Femoston tabl.: t(R) = 13.42 min for didrogesterone; t(R) = 4.85 min for estradiol hemihydrate. The experimental results showed that RP HPLC separation with gradient elution is characterized by higher selectivity. It is found that the detection wavelength lambda = 230 nm is optimal for the achievement of high sensitivity and it is universal for the identification of other active principles and for obtaning of a stable base line with gradient elution. For the GC method: a column HP-35 (30 m x 0.25 mm x 0.25 mu m), temperature program from 100 degrees C to 330 degrees C and mass detection were used. Degradation of analytes at high temperature, their different degree of ionization and the different sensitivity of their detection lead to uncertainty in the GC/MS analysis, therefore, HPLC is the more suitable method for analysis of steroid components.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [41] Validation and Application of a RP - HPLC Method with UV Detection for Loratadine Determination
    Spac, Adrian Florin
    Grigoriu, Ioana Cezara
    Ciobanu, Constantin
    Agoroaei, Luminita
    Strugaru, Anca Monica
    Butnaru, Elena
    REVISTA DE CHIMIE, 2016, 67 (06): : 1227 - 1231
  • [42] STIMULATION OF RAT OVARY BY GONADOTROPINS AND SEPARATION OF STEROIDS BY GAS CHROMATOGRAPHY
    MCKERNS, KW
    NORDSTRA.E
    BIOCHIMICA ET BIOPHYSICA ACTA, 1965, 104 (01) : 237 - &
  • [43] UV and RP-HPLC Method for the Estimation of Lamivudine in Bulk and Pharmaceutical Dosage Forms
    Mohanraj, P.
    Gauthaman, K.
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (02) : 1295 - 1301
  • [44] SEPARATION OF PROTIUM AND DEUTERIUM FORMS OF CARBOHYDRATES BY GAS CHROMATOGRAPHY
    BENTLEY, R
    SAHA, NC
    SWEELEY, CC
    ANALYTICAL CHEMISTRY, 1965, 37 (09) : 1118 - &
  • [45] DETERMINATION OF 1-HYDROXYPYRENE IN RAT URINE USING LIQUID EXTRACTION AND HPLC UV-DETECTION METHOD
    LIPNIAK, M
    GAWLIK, M
    MADEJ, J
    NIEZABITOWSKI, P
    CHEMIA ANALITYCZNA, 1994, 39 (01): : 29 - 32
  • [46] Selective Detection with UV Spectroscopy in Gas Chromatography
    Gras, Ronda
    Luong, Jim
    Shellie, Robert A.
    LC GC NORTH AMERICA, 2021, 39 (10) : 508 - 511
  • [47] High performance liquid chromatographic assays with UV-detection for evaluation of inhibitors of acetylcholinesterase and butyrylcholinesterase
    Michels, Giulia
    Lehr, Matthias
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (5-6) : 309 - 319
  • [48] DETERMINATION OF ARTESUNATE AND DIHYDROARTEMISININE IN PLASMA BY LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION AND UV-DETECTION
    EDLUND, PO
    WESTERLUND, D
    CARLQVIST, J
    WU, BL
    JIN, YH
    ACTA PHARMACEUTICA SUECICA, 1984, 21 (04): : 223 - 234
  • [49] Quantification of anidulafungin and micafungin in human body fluids by high performance-liquid chromatography with UV-detection
    Welte, Rene
    Oberacher, Herbert
    Schwaerzler, Bernhard
    Joannidis, Michael
    Bellmann, Romuald
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1139
  • [50] DETERMINATION OF TRANSITION-METALS IN EDTA COMPLEX FORM BY SINGLE-ION CHROMATOGRAPHY WITH UV-DETECTION
    LITVINA, ML
    VOLOSHCHIK, IN
    RUDENKO, BA