Measurement Configuration Optimization and Kinematic Calibration of a Parallel Robot

被引:14
|
作者
Huang, Chenhui [1 ]
Xie, Fugui [1 ,2 ]
Liu, Xin-Jun [1 ,2 ]
Meng, Qizhi [1 ]
机构
[1] Tsinghua Univ, Dept Mech Engn DME, State Key Lab Tribol, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Beijing Key Lab Precis Ultraprecis Mfg Equipments, Beijing 100084, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
parallel robot; error modeling; measurement configuration optimization; searching algorithm; calibration experiment; DESIGN; PERFORMANCE;
D O I
10.1115/1.4053012
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents the kinematic calibration of a four-degrees-of-freedom (4DOF) high-speed parallel robot. In order to improve the calibration effect by decreasing the influence of the unobservable disturbance variables introduced by error measurement, a measurement configuration optimization method is proposed. Configurations are iteratively selected inside the workspace by a searching algorithm, then the selection results are evaluated through an index associated with the condition number of the identification Jacobian matrix; finally, the number of optimized configurations is determined. Since the selection algorithm has been shown to be sensitive to local minima, a meta-heuristic method has been applied to decrease this sensibility. To verify the effectiveness of the algorithm and kinematic calibration, computation validations, pose error estimations, and experiments are performed. The results show that the identification accuracy and calibration effect can be significantly improved by using the optimized configurations.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Design and kinematic analysis of the wire parallel mechanism for a robot pose measurement
    Jeong, JW
    Kim, SH
    Kwak, YK
    1998 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, 1998, : 2941 - 2946
  • [32] Workspace Measurement and Calibration of a Parallel RCM Craniotomy Surgery Robot
    Dehghani, Mohammadreza
    Moghaddam, Majid M.
    Torabi, Pourya
    5TH INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2018), 2018, 417
  • [33] Geometric configuration in robot kinematic design
    Rooney, Joe
    ROMANSY 16: ROBOT DESIGN, DYNAMICS , AND CONTROL, 2006, 487 : 55 - 62
  • [34] Optimal measurement configurations for kinematic calibration of six-DOF serial robot
    Tian Li
    Kui Sun
    Zong-wu Xie
    Hong Liu
    Journal of Central South University, 2011, 18 : 618 - 626
  • [35] Optimal measurement configurations for kinematic calibration of six-DOF serial robot
    Li Tian
    Sun Kui
    Xie Zong-wu
    Liu Hong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (03): : 618 - 626
  • [36] Self-alignment of on-board measurement sensors for robot kinematic calibration
    Santolaria, Jorge
    Brosed, Francisco-Javier
    Velazquez, Jesus
    Jimenez, Roberto
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2013, 37 (03): : 699 - 710
  • [37] Optimal measurement configurations for kinematic calibration of six-DOF serial robot
    黎田
    孙奎
    谢宗武
    刘宏
    JournalofCentralSouthUniversityofTechnology, 2011, 18 (03) : 618 - 626
  • [38] Sensitivity analysis and kinematic calibration of 3-UCR symmetrical parallel robot leg
    Cheng, Gang
    Ge, Shi-Rong
    Yu, Jing-Li
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2011, 25 (07) : 1647 - 1655
  • [39] Kinematic Calibration of a 2UPR&2RPS Redundantly Actuated Parallel Robot
    Zhang J.
    Jiang S.
    Chi C.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (15): : 62 - 70
  • [40] Sensitivity analysis and kinematic calibration of 3-UCR symmetrical parallel robot leg
    Gang Cheng
    Shi-Rong Ge
    Jing-Li Yu
    Journal of Mechanical Science and Technology, 2011, 25 : 1647 - 1655