Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors

被引:15
|
作者
Bagan, H. [1 ]
Tarancon, A. [1 ]
Rauret, G. [1 ]
Garcia, J. F. [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
Plastic scintillation; Liquid scintillation; Alpha/beta discrimination; Pulse shape analysis; River water samples; Mixed waste; LIQUID SCINTILLATION; RADIOACTIVITY; C-14;
D O I
10.1016/j.aca.2010.04.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Activity determination in different types of samples is a current need in many different fields. Simultaneously analysing alpha and beta emitters is now a routine option when using liquid scintillation (LS) and pulse shape discrimination. However, LS has an important drawback, the generation of mixed waste. Recently, several studies have shown the capability of plastic scintillation (PS) as an alternative to LS, but no research has been carried out to determine its capability for alpha/beta discrimination. The objective of this study was to evaluate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape analysis (PSA). The results obtained show that PS pulses had lower energy than LS pulses. As a consequence, a lower detection efficiency, a shift to lower energies and a better discrimination of beta and a worst discrimination of alpha disintegrations was observed for PS. Colour quenching also produced a decrease in the energy of the particles, as well as the effects described above. It is clear that in PS, the discrimination capability was correlated with the energy of the particles detected. Taking into account the discrimination capabilities of PS, a protocol for the measurement and the calculation of alpha and beta activities in mixtures using PS and commercial scintillation detectors has been proposed. The new protocol was applied to the quantification of spiked river water samples containing a pair of radionuclides (H-3-(241) Am or Sr-90/Y-90-Am-241) in different activity proportions. The relative errors in all determinations were lower than 7%. These results demonstrate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape and to quantify mixtures without generating mixed waste. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 50 条
  • [11] Optical properties and pulse shape discrimination in siloxane-based scintillation detectors
    Marchi, T.
    Pino, F.
    Fontana, C. L.
    Quaranta, A.
    Zanazzi, E.
    Vesco, M.
    Cinausero, M.
    Daldosso, N.
    Paterlini, V
    Gramegna, F.
    Moretto, S.
    Collazuol, G.
    Degerlier, M.
    Fabris, D.
    Carturan, S. M.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [12] Development of indigenous pulse-shape discrimination algorithm for organic scintillation detectors
    Karmakar, Annesha
    Kumar, G. Anil
    Bhavika
    Anand, V.
    Pal, Anikesh
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):
  • [13] Simple algorithms for digital pulse-shape discrimination with liquid scintillation detectors
    Alharbi, T.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 50 - 55
  • [14] APPLICATION OF PULSE SHAPE DISCRIMINATION TO LIQUID SCINTILLATION ALPHA-SPECTROSCOPY
    THORNGATE, JH
    MCDOWELL, WJ
    CHRISTIAN, DJ
    HEALTH PHYSICS, 1974, 27 (01): : 123 - 126
  • [15] Optical properties and pulse shape discrimination in siloxane-based scintillation detectors
    T. Marchi
    F. Pino
    C. L. Fontana
    A. Quaranta
    E. Zanazzi
    M. Vesco
    M. Cinausero
    N. Daldosso
    V. Paterlini
    F. Gramegna
    S. Moretto
    G. Collazuol
    M. Degerlier
    D. Fabris
    S. M. Carturan
    Scientific Reports, 9
  • [16] Principal Component Analysis for pulse-shape discrimination of scintillation radiation detectors
    Alharbi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 240 - 243
  • [17] Rod-shaped pulse shape discrimination plastic scintillation detectors applied for neutron source direction survey
    Koizumi, M.
    Mochimaru, T.
    Hironaka, K.
    Takahashi, T.
    Yamanishi, H.
    Wakabayashi, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [18] ALPHA-PULSE ANALYSIS BY SCINTILLATION DETECTORS
    BERTOLINI, G
    DELTURCO, AM
    RESTELLI, G
    NUCLEAR INSTRUMENTS & METHODS, 1960, 7 (03): : 350 - 354
  • [19] Improving Pulse Shape Discrimination in Organic Scintillation Detectors by Understanding Underlying Data Structure
    Maedgen, Patrick
    Wellons, Benjamin
    Prasad, Shikha
    Tao, Jian
    NUCLEAR TECHNOLOGY, 2022, 208 (10) : 1522 - 1539
  • [20] LIQUID SCINTILLATION ALPHA-PARTICLE ASSAY WITH ENERGY AND PULSE SHAPE DISCRIMINATION
    CROSS, P
    MCBETH, GW
    HEALTH PHYSICS, 1976, 30 (03): : 303 - 306