Novel methods for the quantification of toxic, residual phase transfer catalyst in fluorine-18 labeled radiotracers
被引:4
|作者:
Blevins, David W.
[1
]
Rigney, Grant H.
[1
,2
]
Fang, Michael Y.
[1
,2
]
Akula, Murthy R.
[1
]
Osborne, Dustin R.
[1
]
机构:
[1] Univ Tennessee, Grad Sch Med, 1929 Alcoa Hwy, Knoxville, TN 37920 USA
[2] Univ Tennessee, Dept Mech Aerosp & Biomed Engn, Knoxville, TN USA
关键词:
Absorbance;
Conductance;
Phase-transfer-catalyst;
Radiopharmaceutical;
Transmittance;
CROWN-ETHERS;
COMPLEX-FORMATION;
KRYPTOFIX;
2.2.2;
ALKALI;
TETRABUTYLAMMONIUM;
CHROMATOGRAPHY;
CRYPTANDS;
METAL;
IONS;
FDG;
D O I:
10.1016/j.nucmedbio.2019.07.008
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Introduction: Fluorine-18 labeled radiopharmaceuticals undergo quality control testing for residual phase-transfer-catalyst content. The almost universally used quality-control test is a silica plate spot-test comparison of the radiopharmaceutical beside a 50-ppm standard. Once developed by staining, the radiopharmaceutical spot must be of equal or less intensity to pass the test. There is currently a need for a quantitative, inexpensive, and less subjective quality control method that allows the automatic incorporation of the acquired measurement directly into electronic batch reports. Results: In the developed method, a resazurin test solution is mixed with an aliquot of the radiopharmaceutical analyte along with dichloromethane (DCM). The mixture is vortexed. The potassium resazurin-phase transfer catalyst complex solubilizes into the DCM imparting a blue color. The organic layer is then removed for analysis. Three measurement methods were utilized: visual colorimetry against pre-prepared standards, spectrophotometric measurement of transmittance, and electrical conductance. A simple prototype spectrophotometer and an electrical test cell were constructed to acquire data. Sodium Resazurin dye was found to be a suitable test chromophore for residual phase transfer catalyst analysis of aqueous solutions. Quantitative spectrophotometric measurements are possible in the 0-100-ppm range (18-crown-6) and 0-150-ppm range (Kryptofix (R) or tetrabutylammonium). Electrical resistance measurements of the phase transfer-catalyst resazurin complex in DCM are also a viable method, allowing quantitative phase transfer catalyst measurements in the 0-100-ppm range. Conclusion: The methodologies developed are more quantitative alternatives to the current spot-test method. The spectrophotometric method was determined to be the most accurate method. (C) 2019 The Authors. Published by Elsevier Inc.
引用
收藏
页码:41 / 48
页数:8
相关论文