Effect of geometry and operational parameters on the dehumidification performance of a desiccant coated heat exchanger

被引:2
|
作者
Venegas, Tomas [1 ]
Qu, Ming [1 ]
Nawaz, Kashif [2 ]
Wang, Lingshi [2 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, W Lafayette, IN 47907 USA
[2] Oak Ridge Natl Lab, Knoxville, TN USA
关键词
AIR-CONDITIONING SYSTEM; WATER;
D O I
10.1080/23744731.2022.2077595
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solid desiccant dehumidification systems are an alternative to vapor-compression-based air dehumidification systems. They use solid desiccant materials to adsorb air moisture in space cooling. DCHE can integrate the cooling component in the heat exchanger to achieve higher dehumidification capacity. Comprehensive numeric modeling would be necessary to assist in the design and operation of the DCHE under development to achieve maximum performance. This paper provides the details of a heat and mass transfer model developed for this purpose. The model aims to cover a gap in existing models by independently modeling heat transfer on the solid desiccant, fin, and tube. The model results were compared with an experimental reference for validation. The air outlet humidity and temperature results for dehumidification and regeneration showed a deviation lower than 15% from the experiment. The validated model was used to perform a parametric study for a series of design and operating conditions. The parametric analysis showed that an increase of 25% in desiccant layer thickness and thermal contact resistance between solid elements reduces moisture removal by 9.1% and 1%, respectively. These results indicate the need to independently model the desiccant layer.
引用
收藏
页码:729 / 741
页数:13
相关论文
共 50 条
  • [31] Three-dimensional numerical analysis of fin-tube desiccant-coated heat exchanger for air dehumidification in tropics
    Liu, M.
    Prabakaran, V.
    Bui, T.
    Cheng, G. G.
    Pang, W.
    APPLIED ENERGY, 2023, 331
  • [32] Feasibility study of a parallel plate desiccant coated heat and mass regenerator for dehumidification
    Jagirdar, Mrinal
    Lee, Poh Seng
    Ho, Ghim Wei
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 5034 - 5039
  • [33] The effect of heat exchanger geometry on adsorption chiller performance
    Sosnowski, Marcin
    Grabowska, Karolina
    Krzywanski, Jaroslaw
    Nowak, Wojciech
    Sztekler, Karol
    Kalawa, Wojciech
    XXIII FLUID MECHANICS CONFERENCE (KKMP 2018), 2018, 1101
  • [34] Experimental study on performance of silica gel and potassium formate composite desiccant coated heat exchanger
    Ge, T. S.
    Zhang, J. Y.
    Dai, Y. J.
    Wang, R. Z.
    ENERGY, 2017, 141 : 149 - 158
  • [35] Effects of process air conditions and switching cycle period on dehumidification performance of desiccant-coated heat exchangers
    Chang, Chih-Chang
    Luo, Win-Jet
    Lu, Chi-Wen
    Cheng, Yu-Sheng
    Tsai, Bo-Yi
    Lin, Zhi-Hua
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 81 - 90
  • [36] Performance assessment of heat exchanger coated with encapsulated ultra-high salt content desiccant
    Pan, Q. W.
    Ruan, Y. L.
    Li, X. Y.
    Zhao, Q. Y.
    Wang, B.
    Gan, Z. H.
    APPLIED THERMAL ENGINEERING, 2023, 231
  • [37] Experimental investigation on performance of a novel composite desiccant coated heat exchanger in summer and winter seasons
    Valarezo, Andres S.
    Sun, X. Y.
    Ge, T. S.
    Dai, Y. J.
    Wang, R. Z.
    ENERGY, 2019, 166 : 506 - 518
  • [38] Performance evaluation of MIL-101(Cr) based desiccant-coated heat exchangers for efficient dehumidification
    Ge, Lurong
    Feng, Yaohui
    Wu, Jiarong
    Wang, Ruzhu
    Ge, Tianshu
    ENERGY, 2024, 289
  • [39] Performance evaluation of wavy fin desiccant coated heat exchanger for hot and humid climatic conditions
    Abishraj, V. R.
    Annadurai, Gurubalan
    Simonson, Carey
    Maiya, M. P.
    APPLIED THERMAL ENGINEERING, 2024, 245
  • [40] Experiments on the dehumidification performance of a finned tube heat exchanger
    Chuah, YK
    Hung, CC
    Tseng, PC
    HVAC&R RESEARCH, 1998, 4 (02): : 167 - 178