Dryout occurrence in a helically coiled steam generator for nuclear power application

被引:39
|
作者
Santini, L. [1 ]
Cioncolini, A. [2 ]
Lombardi, C. [3 ]
Ricotti, M. [3 ]
机构
[1] Enel Ingn & Ric SpA, Via Mantova 24, I-00198 Rome, Italy
[2] Univ Manchester, Mech Aerosp & Civil Engn, Manchester M13 9PL, Lancs, England
[3] CeSNEF Nucl Engn Div, Dept Energy, Deputy Head, I-20156 Milan, Italy
关键词
CRITICAL HEAT-FLUX; 2-PHASE FLOW;
D O I
10.1051/epjconf/20146702102
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dryout phenomena have been experimentally investigated in a helically coiled steam generator tube. The experiences carried out in the present work are part of a wide experimental program devoted to the study of a GEN III+ innovative nuclear power plant [1]. The experimental facility consists in an electrically heated AISI 316L stainless steel coiled tube. The tube is 32 meters long, 12.53 mm of inner diameter, with a coil diameter of 1m and a pitch of 0.79 m, resulting in a total height of the steam generator of 8 meters. The thermo-hydraulics conditions for dryout investigations covered a spectrum of mass fluxes between 199 and 810 kg/m2s, the pressures ranges from 10.7 to 60.7 bar, heat fluxes between 43.6 to 209.3 kW/m2. Very high first qualities dryout, between 0.72 and 0.92, were found in the range of explored conditions, comparison of our results with literature available correlations shows the difficulty in predicting high qualities dryout in helical coils., immediately following the heading. The text should be set to 1.15 line spacing. The abstract should be centred across the page, indented 15 mm from the left and right page margins and justified. It should not normally exceed 200 words.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] An experimental study on dryout pattern of two-phase flow in helically coiled tubes
    Chung, WS
    Sa, YC
    Lee, JS
    KSME INTERNATIONAL JOURNAL, 2002, 16 (11): : 1540 - 1549
  • [22] Boiling heat transfer and dryout in helically coiled tubes under different pressure conditions
    Chung, Young-Jong
    Bae, Kyoo-Hwan
    Kim, Keung Koo
    Lee, Won-Jae
    ANNALS OF NUCLEAR ENERGY, 2014, 71 : 298 - 303
  • [23] An experimental study on dryout pattern of two-phase flow in helically coiled tubes
    Won Seok Chung
    Yong-Cheol Sa
    Joon Sik Lee
    KSME International Journal, 2002, 16 : 1540 - 1549
  • [24] Flow Boiling Heat Transfer and Wall Temperature Distributions of Helically Coiled Steam Generator Heated in Oil Bath
    Suzuki, Masatomi
    Kaji, Masuo
    Kuribayasi, Mitsuru
    Matsui, Goichi
    Kataoka, Isao
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 1, 2009, : 317 - +
  • [25] Development of a computer code for thermalehydraulic design and analysis of helically coiled tube once-through steam generator
    Zhang, Yaoli
    Wang, Duo
    Lin, Jianshu
    Hao, Junwei
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (07) : 1388 - 1395
  • [26] Flow structures of the cross-flow over a five-layer helically coiled steam generator geometry
    Lee, Saya
    Hassan, Yassin A.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2022, 95
  • [27] FUNCTIONAL PERFORMANCE OF A 2-TUBE HELICALLY-COILED ONCE-THROUGH STEAM-GENERATOR
    CARTER, HR
    WATSON, GB
    JOHNSON, LE
    MECHANICAL ENGINEERING, 1977, 99 (06) : 115 - 115
  • [28] Development and validation of the helically coiled steam generator model of RELAP5/MOD3.4 code
    Yuan, Yuan
    Zhong, Mingjun
    Zhou, Yuan
    Chao, Fei
    Wang, Li
    PROGRESS IN NUCLEAR ENERGY, 2023, 164
  • [29] Dryout quality prediction for boiling two-phase flow in vertical helically coiled tubes
    Niu, Xiaojuan
    Yuan, Huaijie
    Quan, Chen
    Zhao, Liang
    APPLIED THERMAL ENGINEERING, 2018, 128 : 982 - 992
  • [30] Experimental study on thermal-hydraulic performance of helically coiled tubes steam generator of lead-bismuth reactor
    Gu, Dandan
    Zhu, Lina
    Xiao, Changzhi
    Yang, Hongyi
    International Journal of Advanced Nuclear Reactor Design and Technology, 2024, 6 (01): : 32 - 42