Correlation method of processing single fiber multimode interferometer (SFMI) signals using a charge coupled device

被引:0
|
作者
Kulchin, Y. N. [1 ]
Vitrik, O. B. [1 ]
Lantsov, A. D. [1 ]
机构
[1] Russian Acad Sci, Far Eastern Branch, Inst Automat & Control Proc, Vladivostok 690041, Russia
关键词
fibre interferometer; correlation method for signal processing; speckle pattern;
D O I
10.1117/12.725808
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The correlation method for processing signals from a single-fibre multimode interferometer by using a digital-charge-coupled device is studied experimentally and theoretically. Optimal conditions are determined for recording multimode interference patterns with charge-coupled devices. It is found that the nonlinearity of characteristics of such devices affects the results of correlation measurements. The method for eliminating this influence is proposed. The correlation method considered in the paper allows one to measure a linear deformation of the interferometer within 0-80 mu m with an accuracy of similar to 3 mu m for typical single-mode fibres with the core diameter 50 mu m.
引用
收藏
页数:11
相关论文
共 50 条
  • [42] X-RAY COLOR MOVIE USING THE CHARGE-COUPLED DEVICE WITH A DIRECT X-RAY-DETECTION METHOD
    TSUNEMI, H
    WADA, M
    HAYASHIDA, K
    KWAI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (12A): : 3540 - 3544
  • [43] Assessment of Areal (Three-Dimensional) Roughness Parameters of Milled Surface Using Charge-Coupled Device Flatbed Scanner and Image Processing
    Goh, C. S.
    Ratnam, M. M.
    EXPERIMENTAL TECHNIQUES, 2016, 40 (03) : 1099 - 1107
  • [44] Assessment of Areal (Three-Dimensional) Roughness Parameters of Milled Surface Using Charge-Coupled Device Flatbed Scanner and Image Processing
    C. S. Goh
    M. M. Ratnam
    Experimental Techniques, 2016, 40 : 1099 - 1107
  • [45] Diffuse light reflectance signals as potential indicators of loss of viability in brain tissue due to hypoxia: charge-coupled-device-based imaging and fiber-based measurement
    Kawauchi, Satoko
    Nishidate, Izumi
    Uozumi, Yoichi
    Nawashiro, Hiroshi
    Ashida, Hiroshi
    Sato, Shunichi
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [46] Experimental Study on Single Fiber Tensile Properties of Sisal Fibers Using a Digital Image Correlation Method as a Strain Measurement
    Kassegn, Eshetie
    Sirhabizu, Belete
    Berhanu, Temesgen
    Buffel, Bart
    Desplentere, Frederik
    JOURNAL OF NATURAL FIBERS, 2024, 21 (01)
  • [47] An approach to automated detection of hemolysis in capped, labeled specimens without sampling using a fiber optics charge-coupled device (CCD) array spectrophotometer.
    Stickle, DF
    Moss, PS
    Markin, RS
    CLINICAL CHEMISTRY, 2001, 47 (06) : A116 - A117
  • [48] Performance Evaluation of One-dimensional Fiber-optic Radiation Sensor for Measuring High Energy Electron Beam Using a Charge-coupled Device
    Cho, Dong Hyun
    Jang, Kyoung Won
    Yoo, Wook Jae
    Chung, Soon Cheol
    Tack, Gye Rae
    Eom, Gwang Moon
    Lee, Bongsoo
    Cho, Hyosung
    Kim, Sin
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 477 - 480
  • [49] Room temperature phosphorescence analyses of polycyclic aromatic hydrocarbons using an imaging sensing system combined with a bifurcated optical fiber and a cooled charge coupled device detector
    Ghauch, A
    Rima, J
    Fachinger, C
    Suptil, J
    Martin-Bouyer, M
    TALANTA, 2000, 51 (04) : 807 - 816
  • [50] High-resolution optical refractometer based on a long-period grating Michelson interferometer using a cross-correlation signal-processing method
    Zhou, Xinlei
    Chen, Ke
    Mao, Xuefeng
    Peng, Wei
    Yu, Qingxu
    OPTICAL ENGINEERING, 2015, 54 (12)