Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population

被引:11
|
作者
Bamberg, Fabian [1 ]
Sommer, Wieland H. [1 ]
Schenzle, Jan C. [1 ]
Becker, Christoph R. [1 ]
Nikolaou, Konstantin [1 ]
Reiser, Maximilian F. [1 ]
Johnson, Thorsten R. C. [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
关键词
Cardiac CT; Dual-source CT; Image quality; Systolic reconstruction; Dose reduction; SOURCE CT; ARTERY-DISEASE; IMAGE QUALITY; DIAGNOSTIC-ACCURACY; ATRIAL-FIBRILLATION; INITIAL-EXPERIENCE; STATEMENT;
D O I
10.1007/s00330-009-1680-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the practicability and potential dose saving of an imaging algorithm incorporating a pulsing scheme applying systolic data acquisition at heart rates > 75 beats per minute (bpm). Patients clinically referred for coronary computed tomography angiography (CTA) underwent cardiac CTA using either a diastolic pulsing window (30-70%) or a narrow systolic pulsing window (150 ms at 300 ms). Independent investigators retrospectively determined image quality (1, excellent, to 5, unreadable) and derived effective radiation exposure. Among all 101 subjects (62 +/- 2 years, 59% male) the predicted decrease in the best reconstruction interval for diastolic phases was 12 ms per 1 bpm [95% confidence interval (CI): -13.5 to -11.2] and -1.9 ms for systolic phases (95% CI: -3.2 to -0.62, p = 0.004), independent of age, gender and body mass index (BMI). The systolic pulsing strategy in 47 subjects (23 subjects > 75 bpm) resulted in significantly lower radiation exposure (4.97 +/- 2.3 vs 9.38 +/- 5.5 mSv, p < 0.001 for systolic versus diastolic, respectively), whereas there was no difference with respect to image quality or heart rate (p = 0.65 and p = 0.74, respectively). Our results suggest that a systolic window for tube current modulation in subjects with higher heart rates represents a reliable tool to ensure high image quality at significantly lower dose in patients undergoing routine cardiac CTA.
引用
收藏
页码:1331 / 1336
页数:6
相关论文
共 50 条
  • [1] Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population
    Fabian Bamberg
    Wieland H. Sommer
    Jan C. Schenzle
    Christoph R. Becker
    Konstantin Nikolaou
    Maximilian F. Reiser
    Thorsten R. C. Johnson
    European Radiology, 2010, 20 : 1331 - 1336
  • [2] Safety and accuracy of dual-source coronary computed tomography angiography in the pediatric population
    Han, B. Kelly
    Lindberg, Jana
    Overman, David
    Schwartz, Robert S.
    Grant, Katharine
    Lesser, John R.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (04) : 252 - 259
  • [3] Radiation dose estimates in dual-source computed tomography coronary angiography
    Stolzmann, Paul
    Scheffel, Hans
    Schertler, Thomas
    Frauenfelder, Thomas
    Leschka, Sebastian
    Husmann, Lars
    Flohr, Thomas G.
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2008, 18 (03) : 592 - 599
  • [4] Radiation dose estimates in dual-source computed tomography coronary angiography
    Paul Stolzmann
    Hans Scheffel
    Thomas Schertler
    Thomas Frauenfelder
    Sebastian Leschka
    Lars Husmann
    Thomas G. Flohr
    Borut Marincek
    Philipp A. Kaufmann
    Hatem Alkadhi
    European Radiology, 2008, 18 : 592 - 599
  • [5] Coronary artery anomalies, detection by dual-source computed tomography angiography
    Vliegen, H. W.
    NETHERLANDS HEART JOURNAL, 2010, 18 (10): : 464 - 465
  • [6] Coronary artery anomalies, detection by dual-source computed tomography angiography
    H. W. Vliegen
    Netherlands Heart Journal, 2010, 18 : 464 - 465
  • [7] Dual-source computed tomography coronary angiography in patients with high heart rate
    Fujimura, Tatsuhiro
    Miura, Toshiro
    Nao, Tomoko
    Yoshimura, Masayuki
    Nakashima, Yoshiteru
    Okada, Munemasa
    Okamura, Takayuki
    Yamada, Jutaro
    Ohshita, Chikage
    Wada, Yasuaki
    Matsunaga, Naofumi
    Matsuzaki, Masunori
    Yano, Masafumi
    HEART AND VESSELS, 2014, 29 (04) : 443 - 448
  • [8] Dual-source computed tomography coronary angiography in patients with high heart rate
    Tatsuhiro Fujimura
    Toshiro Miura
    Tomoko Nao
    Masayuki Yoshimura
    Yoshiteru Nakashima
    Munemasa Okada
    Takayuki Okamura
    Jutaro Yamada
    Chikage Ohshita
    Yasuaki Wada
    Naofumi Matsunaga
    Masunori Matsuzaki
    Masafumi Yano
    Heart and Vessels, 2014, 29 : 443 - 448
  • [9] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909
  • [10] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 901 - 909