Percutaneous Axillary Intra-aortic Balloon Pump Insertion Technique as Bridge to Advanced Heart Failure Therapy

被引:9
|
作者
Rosenbaum, Andrew N. [1 ]
Jain, C. Charles [1 ]
Shadrin, Ilya Y. [2 ]
El Hajj, Stephanie C. [1 ]
El Sabbagh, Abdallah [3 ]
Behfar, Atta [1 ,4 ,5 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Cardiovasc Dis, Jacksonville, FL 32224 USA
[4] Mayo Clin, William J von Liebig Ctr Transplantat & Clin Rege, Rochester, MN 55905 USA
[5] Mayo Clin, VanCleve Cardiac Regenerat Med Program, Ctr Regenerat Med, Rochester, MN 55905 USA
关键词
percutaneous; intra-aortic balloon pump technique; mechanical support; heart failure;
D O I
10.1097/MAT.0000000000001259
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In patients with advanced heart failure (HF), temporary mechanical circulator support (TMCS) is used to improve hemodynamics, via left ventricular unloading, and end-organ function as a bridge to definitive therapy. While listed for cardiac transplantation, use of TMCS may be prolonged, preventing adequate mobility. Here, we describe the technique for placement of a percutaneous axillary intra-aortic balloon pump (IABP) using single-site arterial access to facilitate ambulation and subsequent safe removal without surgery or a closure device. Retrospective review of the experience with this approach at a single institution between September 2017 and February 2020 documented feasibility and safety. Baseline demographics, hemodynamic data, and clinical outcomes were collected. Thirty-eight patients had a total of 56 IABPs placed. There were no significant access site or cerebrovascular complications. One fifth of IABPs (21.4%) had balloon failure or migration, requiring placement of a new device, though no patients had significant complications from balloon failure. The majority (81.6%) of patients in the cohort on axillary IABP support were ambulatory and ultimately received the intended therapy (63.2% transplant, 13.2% durable left ventricular assist device, 5.3% other cardiac surgery). Percutaneous, axillary IABP is feasible and associated with an acceptable complication rate as a bridge to definitive therapy.
引用
收藏
页码:e81 / e85
页数:5
相关论文
共 50 条
  • [21] AXILLARY INTRA-AORTIC BALLOON PUMP: NEUROVASCULAR CONSIDERATIONS
    Duarte, Gustavo
    Lopez, Jose L.
    Sanchez, Alejandro
    Uppal, Dipan
    Alonso, Mileydis
    McDonald, Malcolm Lawson
    Snipelisky, David
    Estep, Jerry D.
    Baran, David A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 3559 - 3559
  • [22] Technique of percutaneous supraclavicular subclavian intra-aortic balloon pump placement
    Song, Tae H.
    Jeevanandam, Valluvan
    JTCVS TECHNIQUES, 2021, 8 : 20 - 22
  • [23] Transradial-Guided Percutaneous Transaxillary Intra-aortic Balloon Pump Insertion
    Hayman, Samual
    Lavi, Shahar
    Davey, Ryan
    De, Sabe
    Smith, Stuart
    Bagur, Rodrigo
    CANADIAN JOURNAL OF CARDIOLOGY, 2018, 34 (01) : 92.e5 - 92.e7
  • [24] BRIDGE TO A BRIDGE: INTERMEDIATE-TERM CIRCULATORY SUPPORT WITH THE AXILLARY INTRA-AORTIC BALLOON PUMP
    Nawar, Mohamad A.
    Rashid, Ahmad
    Criswell, Rachel
    Hoff, Steven
    DiSalvo, Thomas D.
    Wigger, Mark A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E317 - E317
  • [25] Expanded Experience with Percutaneous Placement of Axillary-Subclavian Intra-Aortic Balloon Pump that Permits Sitting Upright and Ambulation in Patients with Advanced Heart Failure
    Amione-Guerra, J.
    Cordero-Reyes, A. M.
    Cruz-Solbes, A. S.
    Bhimaraj, A.
    Trachtenberg, B. H.
    Ashrith, G.
    Lin, C. H.
    Bruckner, B.
    Suarez, E. E.
    Torre-Amione, G.
    Park, M. H.
    Estep, J. D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S331 - S331
  • [26] GUIDELINES FOR EFFECTIVE AND SAFE PERCUTANEOUS INTRA-AORTIC BALLOON PUMP INSERTION AND REMOVAL
    VIGNOLA, PA
    SWAYE, PS
    GOSSELIN, AJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (04): : 660 - 664
  • [27] IMPROVED TECHNIQUE OF INTRA-AORTIC BALLOON INSERTION
    MERRILL, JR
    MCCLUSKY, D
    LOGAN, WD
    ANNALS OF THORACIC SURGERY, 1978, 26 (03): : 261 - 262
  • [28] SIMPLIFIED TECHNIQUE FOR INTRA-AORTIC BALLOON INSERTION
    ZADA, F
    MCCABE, JC
    SUBRAMANIAN, VA
    ANNALS OF THORACIC SURGERY, 1980, 29 (06): : 573 - 574
  • [29] Factors Associated with Success of Axillary Intra-aortic Balloon Pump as a Bridge to Transplant Strategy
    Agrawal, Tanushree
    Duran, Antonio
    Tamimi, Omar F.
    Solbes, Ana S. Cruz
    Trachtenberg, Barry
    Guha, Ashrith
    Bhimaraj, Arvind
    JOURNAL OF CARDIAC FAILURE, 2018, 24 (08) : S121 - S121
  • [30] Efficacy of Manual Hemostasis for Percutaneous Axillary Artery Intra-Aortic Balloon Pump Removal
    Tayal, Rajiv
    DiVita, Michael
    Sossou, Christoph W.
    Okoh, Alexis K.
    Stelling, Kelly
    McCabe, James M.
    Kaki, Amir
    Wasty, Najam
    Baran, David A.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2020, 2020