Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures

被引:13
|
作者
Deprez, S. [1 ,2 ]
de Ruiter, Michiel B. [3 ]
Bogaert, S. [4 ]
Peeters, R. [1 ,2 ]
Belderbos, J. [5 ]
De Ruysscher, D. [6 ,7 ]
Schagen, S. [3 ]
Sunaert, S. [1 ,2 ]
Pullens, P. [8 ,9 ]
Achten, E. [4 ]
机构
[1] Univ Hosp Leuven, Dept Radiol, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[3] Netherlands Canc Inst, Div Psychosocial Res & Epidemiol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[4] Ghent Univ Hosp, Dept Radiol, Ghent, Belgium
[5] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[6] Maastricht Univ, Med Ctr, GROW Sch, Dept Radiat Oncol,Maastro Clin, Maastricht, Netherlands
[7] Katholieke Univ Leuven, Radiat Oncol, Leuven, Belgium
[8] Univ Hosp Antwerp, Dept Radiol, Edegem, Belgium
[9] Antwerp Univ, Edegem, Belgium
关键词
Multi-center; Reproducibility; Structural MRI; Diffusion tensor imaging; Resting state fMRI; MRI; RELIABILITY; MULTISITE; PHANTOM; BRAIN; CONNECTIVITY; VARIABILITY; ASSURANCE; NOISE; WATER;
D O I
10.1007/s00234-018-2017-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer. Methods Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers. Results We report average coefficients of variation (CV) below 5% for intrascanner, intravendor, and intervendor reproducibility for both structural and diffusion imaging metrics, except for diffusion metrics obtained from tractography with average CVs ranging up to 7.8%. Additionally, resting-state fMRI showed stable temporal SNR and reliable generation of subjects DMN across vendors and time points. Conclusion These findings indicate that the presented multi-site MRI acquisition protocol can be used in a longitudinal study design and that pooling of the acquired data as part of the phase III longitudinal HA-PCI project is possible with careful monitoring of the results of the half-yearly QA assessment to follow-up on potential scanner-related longitudinal changes in image quality.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 50 条
  • [21] Structural disconnectivity in schizophrenia: a diffusion tensor magnetic resonance imaging study
    Burns, J
    Job, D
    Bastin, ME
    Whalley, H
    MacGillivray, T
    Johnstone, EC
    Lawrie, SM
    BRITISH JOURNAL OF PSYCHIATRY, 2003, 182 : 439 - 443
  • [22] Multi-Center Assessment of Reproducibility of Mass Spectrometry Imaging
    Deininger, Soeren-Oliver
    Bollwein, Christine
    Casadonte, Rita
    Wandernoth, Petra
    Longuespee, Remi
    Kriegsmann, Katharina
    Kriegsmann, Mark
    Kriegsmann, Joerg
    Weichert, Wilko
    Schirmacher, Peter
    Ly, Alice
    Schwamborn, Kristina
    LABORATORY INVESTIGATION, 2019, 99
  • [23] Multi-Center Assessment of Reproducibility of Mass Spectrometry Imaging
    Deininger, Soeren-Oliver
    Bollwein, Christine
    Casadonte, Rita
    Wandernoth, Petra
    Longuespee, Remi
    Kriegsmann, Katharina
    Kriegsmann, Mark
    Kriegsmann, Joerg
    Weichert, Wilko
    Schirmacher, Peter
    Ly, Alice
    Schwamborn, Kristina
    MODERN PATHOLOGY, 2019, 32
  • [24] Resting State Functional Magnetic Resonance Imaging in Parkinson's Disease
    Prodoehl, Janey
    Burciu, Roxana G.
    Vaillancourt, David E.
    CURRENT NEUROLOGY AND NEUROSCIENCE REPORTS, 2014, 14 (06)
  • [25] The Value of Resting-State Functional Magnetic Resonance Imaging in Stroke
    Ovadia-Caro, Smadar
    Margulies, Daniel S.
    Villringer, Arno
    STROKE, 2014, 45 (09) : 2818 - +
  • [26] Resting State Functional Magnetic Resonance Imaging in Parkinson’s Disease
    Janey Prodoehl
    Roxana G. Burciu
    David E. Vaillancourt
    Current Neurology and Neuroscience Reports, 2014, 14
  • [27] Resting state functional magnetic resonance imaging: An emerging clinical tool
    Kesavadas, Chandrasekharan
    NEUROLOGY INDIA, 2013, 61 (02) : 103 - 104
  • [28] Functional magnetic resonance imaging and diffusion tensor imaging in a case of central poststroke pain
    Seghier, ML
    Lazeyras, F
    Vuilleumier, P
    Schnider, A
    Carota, A
    JOURNAL OF PAIN, 2005, 6 (03): : 208 - 212
  • [29] Abnormal Anatomical and Functional Connectivity of the Thalamo-sensorimotor Circuit in Chronic Low Back Pain: Resting-state Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging Study
    Mao, Cui Ping
    Wilson, Georgia
    Cao, Jin
    Meshberg, Nathaniel
    Huang, Yiting
    Kong, Jian
    NEUROSCIENCE, 2022, 487 : 143 - 154
  • [30] Improving functional magnetic resonance imaging reproducibility
    Pernet, Cyril
    Poline, Jean-Baptiste
    GIGASCIENCE, 2015, 4